|
|
CIP error messages related to the relocating loader facility
Error MessageExplanation The loader does not handle variables of this type.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation There is not enough storage to load this file.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative. More storage will probably be needed. You might use the current storage more efficiently by running a different combination of features.
Error MessageExplanation There is not enough storage to load this file.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative. More storage will probably be needed. You might use the current storage more efficiently by running a different combination of features.
Error MessageExplanation The area to free (ATF) array is too small. The ATF array is an array of areas to be freed when an attempted load fails.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The input file is not in the proper format.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The segment version does not match the remainder of the currently loaded software.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The symbols should have been deleted from the table, but were not. This will probably cause problems during future file loads.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The input file is not the correct type for loading.
Recommended Action Check the input file type. If the file type is correct, copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation The loader cannot handle variables of this type.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot handle this type.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An error occurred in the input files.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The input file is not the correct type for loading.
Recommended Action Check the input file type. If the file type is correct, copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation An error prevented the loader from reading a section of the file.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The file being loaded attempted to export a symbol that had already been exported by a previously loaded file.
Recommended Action There is a conflict between loadable files and/or the kernel. Report this error to your technical support representative.
Error MessageExplanation The input file is not in the correct format needed for loading.
Recommended Action Check the input file format. If the format is correct, copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation The input file is not in the correct format needed for loading.
Recommended Action Check the input file format. If the format is correct, copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation The loader could not read the module header information.
Recommended Action Check the file. If it is correct, report this error message to your technical support representative.
Error MessageExplanation The loader cannot handle relocation entries of this type.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation A required symbol is missing.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation Loading is complete, but the close failed.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The CIP has failed to access necessary image files.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An error occurred when attempting to open a file to be loaded.
Recommended Action Confirm that the file exists. Create it if possible. If the problem persists, copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation A required file is currently in use. An open was retried every 5 seconds for 1 minute, before failing the open.
Recommended Action Report this error to your technical support representative, if open fails.
Error MessageExplanation A required file cannot be opened.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader could not read the input file. The load failed.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The space needed for the allocation of a larger area has been exhausted.
Recommended Action Sufficient space should be allocated in advance. Copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation An error prevented the loader from reading a section of the file.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The file is not in the proper format. The loader cannot handle it.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The input file is not the correct version of object file format.
Recommended Action Check the file format version. If the file version is correct, copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation This message precedes other messages relating to loading a file. It is a header to identify the name of the file being loaded.
Recommended Action Copy this message and the following messages. Report this information to your technical support representative.
Error MessageExplanation An error occurred while reading the file headers.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation There is not enough space for the new allocation.
Recommended Action Sufficient space should be allocated in advance. Copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation The version of Cisco IOS software is incompatible with this CIP microcode image.
Recommended Action The Cisco IOS software must be updated to match the CIP version. Report this error to your technical support representative.
Error MessageExplanation The CIP successfully loaded a segment image.
Recommended Action This is an informational message only. No action is required.
Error MessageExplanation This message identifies the segment whose section information follows.
Recommended Action Report this information to your technical support representative.
Error MessageExplanation This message provides data for addresses, sizes, and so on, of modules loaded into the CIP storage.
Recommended Action Report this information to your technical support representative.
Error MessageExplanation This message displays the compile information for the segment listed in the previous line.
Recommended Action Report this information to your technical support representative.
Error MessageExplanation The loader has not been initialized. Therefore, no modules are loaded in CIP storage.
Recommended Action Report this information to your technical support representative.
Error MessageExplanation The loader has not loaded any modules into CIP storage.
Recommended Action Report this information to your technical support representative.
Error MessageExplanation This message precedes and introduces data listing the map of modules loaded into CIP storage. It also acts as a header for the displayed data.
Recommended Action Copy the error message and the lines of data. Report this information to your technical support representative.
Error MessageExplanation This message precedes and introduces data listing the map of modules loaded into CIP storage. It also acts as a header for the displayed data.
Recommended Action Copy the error message and the lines of data. Report this information to your technical support representative.
Error MessageExplanation This message displays the error level on the load failure.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation MAX_RSE_TABS is not sufficient to handle this file.
Recommended Action MAX_RSE_TABS must be increased, and the loadrel.c file must be recompiled. Copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation MAX_SECTION_COUNT is not sufficient to handle this file.
Recommended Action MAX_SECTION_COUNT must be increased, and the loadrel.c file must be recompiled. Copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation MAX_STR_TABS is not sufficient to handle this file.
Recommended Action MAX_STR_TABS must be increased, and the loadrel.c file must be recompiled. Copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation MAX_SYM_TABS is not sufficient to handle this file.
Recommended Action MAX_SYM_TABS must be increased, and the loadrel.c file must be recompiled. Copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation Either the loader cannot process the input file, or the file is not in the proper format.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The input file cannot have dynamic shared objects.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The input file is not in the correct format.
Recommended Action Check the input file format. If the format is correct, copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation A reference from the file being loaded to an external symbol cannot be resolved.
Recommended Action Define all prerequisite external symbols before loading the file. If problems persist, copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation The CIP is unable to compose the microcode image name.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The input file is not in the correct format.
Recommended Action Check the input file format. If the format is correct, copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation The input file is not in the proper format.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The input file cannot have shared objects.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The input file is not in the correct format.
Recommended Action Check the input file format. If the format is correct, copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation The loader requires a file to be loaded to have an entry, loader_segment_version, containing a specific structure.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An error occurred while the file was being read.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot handle relocation entries of this type.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader could not read part of the file.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot handle this type of relocation.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot handle this type of relocation.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation Either the prerequisite files are not loaded, or there are incorrect references.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot process this type of section of the code.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An error occurred positioning within the file.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot handle this file.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot handle variables of this type.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot handle variables of this type.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot allocate a larger variable to an already loaded smaller variable.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot handle this type.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader could not read a needed section of the file.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An error prevented reading a necessary part of the file for loading.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot handle this file.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The preallocated area is not large enough.
Recommended Action The loader must be recompiled with more area. Copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation The loader cannot handle variables of this type.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The preallocated area is not large enough for loading.
Recommended Action The loader must be recompiled with more area. Copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation This is an error in the input file.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The preallocated area is not large enough for loading.
Recommended Action The loader must be recompiled with more area. Copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation The loader cannot handle variables of this type.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot handle variables of this type.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot handle variables of this type.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The loader cannot handle variables of this type.
Recommended Action Report this error to your technical support representative.
CIP error message related to the mechanism that sends statistics from the CIP to the router
Error MessageExplanation An attempt was made to transfer statistics to the RP. The DMA routines returned the wrong transfer request.
Recommended Action The CIP has recovered. Report this error to your technical support representative.
Memory buffer error messages
Error MessageExplanation A request was made to free an mbuf that was already free.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An unexpected internal error has occurred in the TCP/IP stack.
Recommended Action Report this error to your technical support representative.
CIP error message related to the memory device facility
Error MessageExplanation An IPC message was queued to the CIP and there was no handler defined to process it.
Recommended Action The CIP dropped the IPC message. Report this error to your technical support representative.
Error MessageExplanation While processing a buffer queue in MEMD, a pointer was found to have an invalid value.
Recommended Action The CIP dropped the packet. Report this error to your technical support representative.
Error MessageExplanation A packet was queued to the CIP and the virtual circuit associated with the packet is not valid.
Recommended Action The CIP dropped the packet. Report this error to your technical support representative.
Error MessageExplanation This message contains a hex dump of data associated with the immediately preceding error message.
Recommended Action Forward a copy of the entire hex dump to your Cisco technical support representative.
Error MessageExplanation This message contains a hex dump of data associated with the immediately preceding error message.
Recommended Action Forward a copy of the entire hex dump to your Cisco technical support representative.
Error MessageExplanation This message contains the start address of a data frame with a bad virtual circuit number.
Recommended Action Forward a copy of this message to your Cisco technical support representative.
Error MessageExplanation When attempting to deregister a routine to handle data for a given virtual circuit, the virtual circuit number was out of range. The deregistration request is ignored.
Recommended Action Restart the CIP. Report this error to your technical support representative.
Error MessageExplanation When attempting to register a routine to handle data for a given virtual circuit, the virtual circuit number was out of range. No messages for the given virtual circuit will be accepted, and additional error messages will be generated for each message.
Recommended Action Restart the CIP. Report this error to your technical support representative.
Error MessageExplanation A packet has been queued for the CIP with a valid virtual circuit number, but the virtual circuit number is associated with the other port adapter.
Recommended Action The CIP dropped the packet. Report this error to your technical support representative.
MultiPath Channel error messages
Error MessageExplanation This informational message is given when an XID2 message specifies a subchannel read/write transfer direction differently from the direction configured.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This error message is given when an MPC DLC frame is received and the DLC command is not recognized.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This error message is given when an MPC block is received and the header configuration is not recognized.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This error message is given when an MPC block is received and the header configuration is not recognized.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This error message is given when an MPC block is received with a sequence number error.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This informative message is given when an MPC device is initialized. The device string is in the form PA x MPC yyyy-zz, where x is the port adapter number, yyyy is the path and zz is the device number.
Recommended Action No action is required.
Error MessageExplanation This error message is given when an MPC frame is received with a length value that is inconsistent with the channel block length.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This informative message is given when an attempt is made to configure an MPC link that has already been configured.
Recommended Action No action is required.
Error MessageExplanation This informative message is given when a message if received for an MPC link where the transmission group has not been configured.
Recommended Action No action is required.
Error MessageExplanation This error message is given when a call to create a pool or get a buffer fails.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This error message is given when an internal state machine attempts to execute an event inconsistent with the state.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This informative message is given when the sequence number in a block from the host has wrapped.
Recommended Action No action is required.
Error MessageExplanation This informative message is given when an MPC device is shut down. The device string is in the form PA x MPC yyyy-zz, where x is the port adapter number, yyyy is the path and zz is the device number.
Recommended Action No action is required.
Error MessageExplanation This error message is given when an internal state machine attempts to execute an event inconsistent with the state.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This error message is given when an internal state machine attempts to execute an event inconsistent with the state.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This error message is given when an MPC sweep command is received with a sequence number error.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An invalid parameter was received in a SYSMGT call.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An invalid parameter was received in a SYSMGT call.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An invalid parameter was received in a SYSMGT call.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An invalid parameter was received in a SYSMGT call.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This error message is given when an MPC subchannel is in the XID2 exchange state and the message received has a length that is not valid for an XID2 message segment.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This error message is given when an XID2 frame is received and the header configuration is not recognized.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This error message is given when an internal state machine attempts to execute an event inconsistent with the state.
Recommended Action Report this error to your technical support representative.
CIP 802 error messages related to the IEEE 802.2cx Logical Link Control (LLC) protocol stack
Error MessageExplanation An attempt was made to configure more than 18 CSNA adapters. A maximum of 18 CSNA adapters are allowed per CIP.
Recommended Action Reduce the number of CSNA adapters configured to comply with the 18 CSNA adapter limit.
Error MessageExplanation This is an informative message given for bringing up each adapter specified.
Recommended Action No action is required.
Error MessageExplanation This is an informative message given for removing each adapter specified.
Recommended Action No action is required.
Error MessageExplanation This is an informative message given for changing the LLC parameters for each adapter specified.
Recommended Action No action is required.
Error MessageExplanation The LLC protocol stack has received a bad frame that contains an invalid Ns from its peer. The problem is often caused by mis-configuration of LLC parameters. Fine tuning of the LLC parameters of the CIP adapter and its peer might be required to correct this problem. This warning message is only displayed for every 500 occurrences of BAD Ns detected for the given connection.
Recommended Action Fine tuning of the LLC parameters of CIP adapter and its peer might be required to correct this problem.
Error MessageExplanation This message means that the CTA mapper is not able to honor the maximum connection as configured, most likely because of running out of resources (such as a shortage of memory). Any attempt to decrease the maximum connection will be rejected. It might be rejected by the mapper because of lack of memory.
Recommended Action Verify if overconfigured by checking the maximum numbers of connections configured. If not, report this error to your technical support representative.
Error MessageExplanation The MEMD buffer currently supported a maximum frame size of 4472 bytes. CSNA detected that the frame sent is larger than what it should be and the frame was discarded. This error most likely occurred because the maximum frame length is misconfigured.
Recommended Action Check the maximum frame length configured.
Error MessageExplanation The protocol stack encountered error conditions that prevent it from continuing its normal operations.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The LLC task detected an invalid configuration command. The command is rejected.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The LLC has received an invalid ID type. Currently, such an ID type is not supported. The request is discarded.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The LLC task detected an invalid MSI command. The request is discarded.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The LLC has received an invalid service primitive. The module and routine that received such a primitive and the Service Primitive code are displayed.
Recommended Action This is not a fatal error and the CSNA should be able to continue to operate. If somehow, the error becomes disruptive, report this error to your technical support representative.
Error MessageExplanation Unable to process the configuration command because an invalid VCN was detected. The configuration command is rejected.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation Unable to process the configuration command because an invalid VCN was detected. The configuration command is rejected.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An open station was received but the station address is already open.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation Two SAP users have tried to open the same SAP number on the same adapter. A SAP user may be an XCA Major Node, a TN3270 Server PU, or TN3270 Server DLUR.
Recommended Action Check XCA Node definitions.
Error MessageExplanation This is an informative message given for shutdown of the LLC. Both the LLC MEMD READ/WRITE task and the TIMER task were taken down.
Recommended Action No action is required.
Error MessageExplanation This is an informative message given for bringing up an LLC subsystem.
Recommended Action No action is required.
Error MessageExplanation This message means that CIP is not able to honor the maximum connection as configured, most likely because of running out of resources (such as shortage of memory). Any attempt to decrease the maximum connection will be rejected. It might be rejected by the mapper because of lack of memory.
Recommended Action Verify if overconfigured by checking the maximum numbers of connections configured. If not, report this error to your technical support representative.
Error MessageExplanation This message means that CIP is not able to honor the maximum connection as configured, because it was unable to allocate a MSG buffer from the CIPMSG pool.
Recommended Action Enter the max_llc command again. If the error persists, report this error to your technical support representative.
Error MessageExplanation The maximum number of concurrent LLC connections has been exceeded.
Recommended Action Increase the MAX_LLC_SESSIONS parameter on the CIP virtual interface.
Error MessageExplanation MEMD should never be in an odd boundary. This check is added to detect any possible run-time errors.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The LLC task detected a queue open failure. Most likely the resource is not available for such a request.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The protocol stack encountered error conditions that prevent it from continuing its normal operations. Possible error such as resource depletion.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This is an informative message given for reduce max_conn. Reducing the max_conn is not allowed for this release.
Recommended Action No action is required.
Error MessageExplanation This message means that LLC is in shutdown cleanup state. All configuration commands are subsequently rejected.
Recommended Action Retry the command when the LLC is in operational state.
Error MessageExplanation This message means that CIP is not able to bring up the CTA 802 task, most likely because it is running out of resources (such as shortage of memory).
Recommended Action Verify if overconfigured. Check the maximum number of connections configured. Report this error to your technical support representative.
Error MessageExplanation The LLC task detected an unknown event.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The LLC task detected an unsupported function being requested. The request is voided.
Recommended Action Report this error to your technical support representative.
Error messages related to the CIP interrupt controller
Error MessageExplanation An attempt was made to specify an interrupt handler for an invalid interrupt type on the Nevada interrupt control chip. This is a fatal internal logic error.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An attempt was made to disable an invalid interrupt type on the Nevada interrupt control chip. This is a fatal internal logic error.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An attempt was made to enable an invalid interrupt type on the Nevada interrupt control chip. This is a fatal internal logic error.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An attempt was made to enable an interrupt routine on the Nevada interrupt control chip, but there was no interrupt routine specified. This is a fatal internal logic error.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An interrupt was received for a code with no interrupt handler defined. This is a fatal internal logic error.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An attempt was made to remove an interrupt handler for an invalid interrupt type on the Nevada interrupt control chip. This is a fatal internal logic error.
Recommended Action Report this error to your technical support representative.
CIP error messages related to the offload protocol
Error MessageExplanation The host sent a socket request with an invalid socket descriptor. The CIP sent an error response to this socket request. This could be a host error or a CIP internal logic error.
Recommended Action This message is followed by a dump of the request. Copy the error messages exactly as they appear, and report them to your technical support representative.
Error MessageExplanation The host sent a socket request that should be the last in a sequence but is not. This error is caused either by an internal logic error, or by an incompatibility between the offload code on the mainframe and the offload code on the CIP.
Recommended Action This message is followed by a hex dump of the offending sequence of offload messages. Copy the error messages exactly as they appear, and report them to your technical support representative.
Error MessageExplanation The host sent an offload command with an invalid offload command code.
Recommended Action The CIP has ignored the request. Report this error to your technical support representative.
Error MessageExplanation This message contains a hex dump of data associated with the immediately preceding error message.
Recommended Action Forward a copy of the entire hex dump to your Cisco technical support representative.
Error MessageExplanation This message contains a hex dump of data associated with the immediately preceding error message.
Recommended Action Forward a copy of the entire hex dump to your Cisco technical support representative.
Error MessageExplanation An internal logic error occurred. An offload message header crossed a buffer boundary.
Recommended Action The CIP ignored the request. Copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation An internal logic error occurred. The buffer length field in the offload message header does not equal the size of the data buffer.
Recommended Action The CIP assumes the offload message header contains no data. Copy the error message exactly as it appears, and report it to your technical support representative.
Error MessageExplanation An internal logic error occurred. A sequence of buffers was attempted to be freed, but was incomplete.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An internal logic error occurred. A sequence of buffers was attempted to be freed, but was incomplete.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The offload initialization code found an internal error.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The host sent an offload restart request with too many defined interfaces.
Recommended Action The CIP has ignored the request. Check your host configuration for this offload device. Report this error to your technical support representative.
Error MessageExplanation The amount of data being read by the channel exceeded the size of the read CCW.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The host sent an offload restart request with an unknown IP address for the API link.
Recommended Action The CIP has ignored the mismatch. Correct your host configuration for this offload device.
Error MessageExplanation The offload application received a message after a shutdown. This is an internal logic error. The message was ignored.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An internal logic error occurred. Not enough memory buffers were allocated to handle the current offload socket operation.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation Not enough free memory is available to start the TCP/IP offload tasks. The configuration request was ignored.
Recommended Action Install more memory for the CIP, or configure fewer devices.
Error MessageExplanation A request to free a send buffer was made even though there is no send pending. This is an internal logic error.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation No transmit buffers are available for sending a RESTART response.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The offload application had to save a socket request for later execution while another request of the same type was pending. This is an internal logic error. The first request was dropped.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation Not enough free memory is available to open another socket. The socket request failed.
Recommended Action Install more memory for the CIP, configure fewer devices, or limit the number of sessions through this offload device.
Error MessageExplanation The host sent a socket request with an invalid parameter. The CIP sent an error message in response to this request.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The host sent a socket request with an incorrect length. The CIP sent an error message in response to this request.
Recommended Action This message is followed by a hex dump of the offending offload message. Copy the error messages exactly as they appear, and report them to your technical support representative.
Error MessageExplanation The host sent a socket request with an unknown type.
Recommended Action The CIP has ignored the request. Report this error to your technical support representative.
Error MessageExplanation The host sent a send socket request that had an unexpected serial number in the header. This is most likely a bug on the host.
Recommended Action The CIP sent an error response to the send socket request. The host TCP/IP stack will probably print the error message, "Unexpected result from Offload device...." Copy the error messages exactly as they appear, and report them to your technical support representative.
Error MessageExplanation When the offload application quit, it detected sockets that were still waiting for cleanup. This is an internal logic error.
Recommended Action This message should be preceded by other error messages that provide further information. Copy the error messages exactly as they appear, and report them to your technical support representative.
Error MessageExplanation The host sent a socket request with an invalid code.
Recommended Action The CIP has ignored the request. Report this error to your technical support representative.
Error MessageExplanation An internal logic error occurred. The request type in the offload message was valid, but unexpected.
Recommended Action The CIP has ignored the request. Report this error to your technical support representative.
Error MessageExplanation An attempt was made to configure an offload device on the virtual port adapter. Offload devices are permitted on physical port adapters only.
Recommended Action The configuration request was ignored. No action is required.
Error MessageExplanation The offload application received a message consisting of more than one xfer_element. This is currently not supported.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The host sent a purge socket request that contained the host descriptor instead of the offload box descriptor. This is most likely a bug or an obscure feature on the host.
Recommended Action If the CIP found the specified host descriptor, it processed the purge request. Otherwise, it ignored it. Copy the error messages exactly as they appear, and report them to your technical support representative.
Error MessageExplanation An internal logic error occurred. An unexpected address was specified in a request to free a buffer
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An attempt was detected to send a packet in an mbuf on CLAW link 0. This is an internal logic error. The packet was ignored.
Recommended Action Report this error to your technical support representative.
CIP error messages related to the storage control block
Error MessageExplanation An attempt was made to free SCB 0. This is an internal logic error. The request was ignored.
Recommended Action Report this message to your technical support representative.
Error MessageExplanation A task waiting for a channel storage control block woke up. This message is typically preceded by the message, "SCB limit on port reached." The correlator value in this message and the following message indicate that the two messages form a pair. In most cases, the pair of messages indicates a burst of activity that resulted in an unusually long queue for the channel.
Recommended Action This is an informational message. No action is required.
Error MessageExplanation A task tried to allocate a channel storage control block when all blocks were in use. The task is now waiting for a block to become available. This message is typically followed by the message, "SCB on port available." The correlator value in this message and the following message indicate that the two messages form a pair. In most cases, the pair of messages indicates a burst of activity that resulted in an unusually long queue for the channel.
Recommended Action If this message is followed by any kind of indication that the CIP stopped working properly, report it to your technical support representative, along with the output of the following commands:
In addition, check the multiple virtual storage (MVS) syslog and the TCPIP joblog (or equivalent for other mainframe operating systems) for unusual channel-related messages. Pay particular attention to anything related to TCP/IP offload.
Error messages related to the scheduler, the facility responsible for determining which process to run at a given time on the CIP
Error MessageExplanation A request was made to create a process, but the priority for the process was not valid. The process was not created.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An attempt was made to request a lock, but the lock word contained invalid data. This is a fatal internal logic error.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An attempt was made to unlock a lock, but the data in the lock word was not valid. This is a fatal internal logic error.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This message contains data that relates to the "SCHED-0-NOTMYLOCK" message.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An attempt was made to unlock a lock that was not held. This is a fatal internal logic error.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An attempt was made to create more tasks than the CIP is designed to allow. The process was not created.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An attempt was made to create a process and not sufficient storage was available to contain the stack for the process. The process was not created.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An attempt was made to create a process and sufficient storage was not available to contain the control block for the process. The process was not created.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An attempt was made to unlock a lock that was set by another task. This is a fatal internal logic error.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation An attempt was made to lock while not at the process level. This is a fatal internal logic error.
Recommended Action Report this error to your technical support representative.
CIP error messages related to the serial link controller
Error MessageExplanation After servicing a Non-Maskable Interrupt from a PCA interface, the attempt to reset the interrupt failed.
Recommended Action Report this message to your technical support representative.
Error MessageExplanation An attempt to scan the first set of internal latches on the Enterprise Systems Connection (ESCON) processor failed.
Recommended Action Report this message to your technical support representative.
Error MessageExplanation An attempt to scan the second set of internal latches on the Enterprise Systems Connection (ESCON) processor failed.
Recommended Action Report this message to your technical support representative.
Error MessageExplanation An attempt to scan the internal latches of the serial link controller failed.
Recommended Action Report this message to your technical support representative.
Error MessageExplanation An attempt was made to stop the clock on the interface between the Enterprise Systems Connection (ESCON) processor and the serial link controller. The serial link controller did not indicate that the clock was stopped.
Recommended Action Report this message to your technical support representative.
Error MessageExplanation An attempt was made to stop the clock on the Enterprise Systems Connection (ESCON) processor. The serial link controller did not indicate that the clock was stopped. The CIP attempted to stop the BIDI clock.
Recommended Action Report this message to your technical support representative.
CIP error messages related to the SLC Interface
Error MessageExplanation This error message is given when an MPC process receives a xfer_list with an unrecognized type code.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This error message is given when an internal state machine attempts to execute an event inconsistent with the state.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This error message is given when an internal state machine attempts to execute an event inconsistent with the state.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This error message is given when a call to create a pool or get a buffer fails.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The error message is given when the internal stash validation fails on mismatch between an mbuf data address and a storage control block (SCB) data address.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The error message is given when a read operation completes, but there was no stashed data.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The error message is given when the internal stash validation fails because the mbuf chain is longer than the storage control block (SCB) chain.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation The error message is given when the internal stash validation fails because the storage control block (SCB) chain is longer than the mbuf chain.
Recommended Action Report this error to your technical support representative.
CIP SSI802 error messages related to the common service System Service Interface (SSI) facility
Error MessageExplanation This message is used by the dump utility to display the hex dump of storage.
Recommended Action No action is required.
Error MessageExplanation The CSNA encountered unrecoverable error conditions that prevent it from continuing its normal operations.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This is a debug feature to show the return address when an ASSERT is used in an inline function.
Recommended Action Action according to subsequent error.
Software subsystem error messages
Error MessageExplanation A software consistency check failed.
Recommended Action Call your technical support representative for assistance.
Error MessageExplanation A software consistency check failed.
Recommended Action Call your technical support representative for assistance.
Error MessageExplanation A software consistency check failed.
Recommended Action Call your technical support representative for assistance.
Error MessageExplanation A software consistency check failed.
Recommended Action Call your technical support representative for assistance.
Error MessageExplanation A software consistency check failed.
Recommended Action Call your technical support representative for assistance.
Error MessageExplanation A software consistency check failed.
Recommended Action Call your technical support representative for assistance.
CIP operating system error messages
Error MessageExplanation A block of memory is corrupt at the indicated location.
Recommended Action If this message recurs, call your technical support representative for assistance.
Error MessageExplanation A block of memory is corrupt at the indicated location.
Recommended Action If this message recurs, call your technical support representative for assistance.
Error MessageExplanation A pointer in the block header at the indicated location is corrupt.
Recommended Action If this message recurs, call your technical support representative for assistance.
Error MessageExplanation The free memory pool is corrupted.
Recommended Action Call your technical support representative for assistance.
Error MessageExplanation An internal software error has occurred.
Recommended Action If this message recurs, call your technical support representative for assistance.
Error MessageExplanation An internal software error has occurred.
Recommended Action If this message recurs, call your technical support representative for assistance.
Error MessageExplanation An internal software error has occurred.
Recommended Action If this message recurs, call your technical support representative for assistance.
Error MessageExplanation An internal software error has occurred.
Recommended Action If this message recurs, call your technical support representative for assistance.
Error MessageExplanation An internal software error has occurred.
Recommended Action If this message recurs, call your technical support representative for assistance.
Error MessageExplanation This message indicates that a memory allocation or deallocation was attempted from an interrupt handler.
Recommended Action If this message recurs, call your technical support representative for assistance.
Error MessageExplanation The CIP is running short on memory.
Recommended Action It may be necessary to free some memory by exiting a program. If this message recurs, call your technical support representative for assistance.
Error MessageExplanation The CIP software has become large enough that it will not run with only 2 MB of DRAM.
Recommended Action Contact your support representative for a free 8 MB upgrade.
Error MessageExplanation The free memory pool is corrupted.
Recommended Action If this message recurs, contact your technical support representative for assistance.
Error MessageExplanation The system detected an error while checking memory fragmentation.
Recommended Action If this message recurs, call your technical support representative for assistance.
Error MessageExplanation An operation could not be accomplished because of a low-memory condition.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
Error MessageExplanation A block of memory in the free pool is actually in use. The number of processes using the memory block is indicated.
Recommended Action If this message recurs, call your technical support representative for assistance.
Error MessageExplanation An internal software error has occurred.
Recommended Action If this message recurs, contact your technical support representative for assistance.
Error MessageExplanation A reload or restart has been requested.
Recommended Action This is a notification message only. No action is required.
Error MessageExplanation A reload or restart has been requested.
Recommended Action This is a notification message only. No action is required.
Error MessageExplanation A freed buffer has been placed on the wrong list of free buffers.
Recommended Action If this message recurs, call your technical support representative for assistance.
CIP error messages related to network management processing for system management remote procedure calls
Error MessageExplanation This message indicates a System Management event sending operation failure. Traps, alerts, and console messages for a channel event will not be generated.
Recommended Action If this error recurs, report it to your technical support representative.
Error MessageExplanation A system error has been detected in the Systems Management Remote Procedure Call processing.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation This message indicates a System Management Remote Procedure Call operation failure. Request for information from the Channel Adapter card will not be processed.
Recommended Action Report this error to your technical support representative.
Error MessageExplanation Channel Adapter System Management could not initialize because of a lack of memory available on the Channel Adapter. Since the Channel Adapter SYSMGT component was unable to initialize, most show extended channel command information and all Channel Adapter event notifications will not be available to the user.
Recommended Action Upgrade the Channel Adapter with more memory.
Error MessageExplanation The Channel Adapter System Management subsystem has changed state.
Recommended Action This is an informational message only. No action is required.
Error messages related to the TN3270 server feature of the CIP card
Error MessageExplanation The TN3270 server could not change the maximum number of LUs to the requested value. The previous number is still in use.
Recommended Action Review the previous error messages to discover what caused the failure, and take action based on those messages.
Error MessageExplanation An important semaphore could not be created.This is either because of memory shortage or some internal code error.
Recommended Action This is most probably because of insufficient memory on the board. Upgrade your board with additional memory. If you believe sufficient memory is on the board, it is possible that there is a memory leak. Report details of your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem to your technical support representative.
Error MessageExplanation An important buffer pool could not be created. This is either because of memory shortage or some internal code error.
Recommended Action This is most probably because of insufficient memory on the board. Upgrade your board with additional memory. If you believe sufficient memory is on the board, it is possible that there is a memory leak. Report details of your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem to your technical support representative.
Error MessageExplanation An important thread could not be created. This is either because of memory shortage or some internal code error.
Recommended Action This is most probably because of insufficient memory on the board. Upgrade your board with additional memory. If you believe sufficient memory is on the board, it is possible that there is a memory leak. Report details of your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem to your technical support representative.
Error MessageExplanation TheTN3270 server cannot complete one or more connection requests from a TN3270/E client because the host does not support dynamic definition of dependent LUs (DDDLU).
Recommended Action Check that all PUs configured for use with DDDLU have the LUGROUP operand defined. Also, check that the specified VTAM LUGROUP major node is active.
Error MessageExplanation The client software is not behaving as per RFC.
Recommended Action Try to locate the TN3270 client that caused the problem. There could be a bug in the client.
Error MessageExplanation An exclusive lock is being released illegally by the executing thread. The lock is either held by no one or by some other thread.
Recommended Action To recover, you must microcode reload the CIP. Since this problem is very serious, you might get this error again. In any case, send output of this message and tasks on CIP console to your technical support representative. Also, send your configuration and any action you must do to get this problem.
Error MessageExplanation The client software is not behaving as per RFC.
Recommended Action Try to locate the TN3270 client that caused the problem. There could be a bug in the client.
Error MessageExplanation There was an attempt to bring up a PU, but listening on the corresponding TCP/IP port could not be started.
Recommended Action Check that sufficient memory is present on the CIP card. Report this error to your technical support representative.
Error MessageExplanation Insufficient memory prevents proper operation of TN3270 server.
Recommended Action Ensure that enough memory is available on the board. Upgrade the memory on the board or cancel other services running on the CIP. If you believe sufficient memory is on the board, it is possible that there is a memory leak. Report details of your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem to your technical support representative.
Error MessageExplanation An unexpected event was presented to the LU named by the LOCADDR and PU. The error may cause the TN3270 session to not work properly. More detail on this error is contained in the "LU_ERROR_INFO" messages immediately following this message.
Recommended Action Report this problem to your technical support representative.
Error MessageExplanation This message shows information about the LU state, history, and flags before the error happened.
Recommended Action Report this problem to your technical support representative.
Error MessageExplanation Some preallocated LU buffers for transmission have run out. The transmission of the message is aborted. The LU session is left incomplete. In addition, the LU session could hang.
Recommended Action Use the show command to find out as much as possible about the LU state and report the information to your technical support representative.
Error MessageExplanation This message indicates that the number of LU sessions is approaching the configured maximum-lus setting.
Recommended Action No action is required.
Error MessageExplanation Memory could not be allocated for an important operation.
Recommended Action Upgrade your board for additional memory. If you believe sufficient memory is on the board, it is possible that there is a memory leak. Report details of your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem to your technical support representative.
Error MessageExplanation A TN3270E client sent a negative response to a TN3270 request sent previously by the server. The negative response does not have a sequence number that can be correlated by the server.
Recommended Action Determine the DLOGMOD used for the session. Review the outbound pacing bits used for this session and ensure that the pacing value is no bigger than 4. If problems persist, contact the client software vendor and lodge a problem report.
Error MessageExplanation Either a BIND REQUEST or SSCP-LU data was expected (but not received) from the host within 30 seconds from the start of SSCP-LU session for this TN3270 session. If the condition persists for another 2 minutes, the LU is declared bad. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.
Recommended Action Examine the system services control point (SSCP) host VTAM console for status of the specified PU and LU. Review the VTAM console log output for relevant events (such as deactivation of the PU or LU). If, after VTAM console review, the cause is still unknown, report this error to your technical support representative. A temporary workaround is simply to recycle the affected LU at the VTAM console. This will put the LU back into normal circulation.
Error MessageExplanation The host has not sent an ACTLU REQ within 30 seconds of sending a Reply-PSID RSP. If this condition persists for another 2 minutes, the current TN3270 session connected to the LU is disconnected. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.
Recommended Action Examine the system services control point (SSCP) host VTAM console for status of the specified PU and LU. Review the VTAM console log output for relevant events (such as deactivation of the PU or LU). If, after VTAM console review, the cause is still unknown, report this error to your technical support representative. A temporary workaround is simply to recycle the affected LU at the VTAM console. This will put the LU back into normal circulation.
Error MessageExplanation The TN3270 server has events that will result in SNMP traps and/or SNA Alerts, but has not been able to allocate IPC buffer resources to report the events to router system code. The TN3270 server will continue to try to report these events, but lack of buffers may continue until a CIP microcode reload is performed.
Recommended Action Report this problem to your technical representative. Include output from the following commands:
As a workaround, reload the CIP microcode.
Error MessageExplanation Insufficient memory is available to the TN3270 server to complete one or more requests by TN3270/E clients for LU sessions. The sessions have been disconnected.
Recommended Action Review the memory required to run the TN3270 server application in light of current client load. Install additional memory, if necessary.
Error MessageExplanation The TN3270 server cannot complete one or more connection requests from a TN3270/E client because no more available LUs are left in the generic pool associated with the specified IP listening-point address.
Recommended Action Review the LU requirements for the application endpoints. Configure additional PUs listening at the specified IP address and port number.
Error MessageExplanation No response to a power-on (AVAILABLE) NOTIFY request was received by the TN3270 server within 30 seconds of sending it to the host. If this condition persists for another 2 minutes, the current TN3270 session connected to the LU is disconnected. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.
Recommended Action Examine the system services control point (SSCP) host VTAM console for status of the specified PU and LU. Review the VTAM console log output for relevant events (such as deactivation of the PU or LU). If, after VTAM console review, the cause is still unknown, report this error to your technical support representative. A temporary workaround is simply to recycle the affected LU at the VTAM console. This will put the LU back into normal circulation.
Error MessageExplanation No response to a power-off (UNAVAILABLE) NOTIFY request was received by the TN3270 server within 30 seconds of sending it to the host. If this condition persists for another 2 minutes, the current TN3270 session connected to the LU is disconnected. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.
Recommended Action Examine the system services control point (SSCP) host VTAM console for status of the specified PU and LU. Review the VTAM console log output for relevant events (such as deactivation of the PU or LU). If, after VTAM console review, the cause is still unknown, report this error to your technical support representative. A temporary workaround is simply to recycle the affected LU at the VTAM console. This will put the LU back into normal circulation.
Error MessageExplanation No response to a Reply PSID was received by the TN3270 server within 30 seconds of sending it to the host. This fault can only occur on dynamic LUs that have been misconfigured or de-activated at the host. If this condition persists for another 2 minutes, the current TN3270 session connected to the LU is disconnected. Bad dynamic LUs are placed in a special area where no attempt to reuse them is made until all other generic-pool LUs of the IP listening point have been exhausted.
Recommended Action Check the status of the LU via VTAM, and vary the LU active if appropriate. This action must happen within 2 minutes of the time that this message appears; otherwise, the LU is placed in "bad" LU area and will not be reused unless all good LUs are in use. Examine the host VTAM log for trouble. In particular, look for messages indicating a badly configured LUGROUP resource definition or file. Fix the configuration and recycle the affected major nodes.
Error MessageExplanation No SDT (Start Data Transfer) REQ was received by the TN3270 server from the PLU host for the specified LU. If the condition persists for another 2 minutes, the LU is declared bad. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.
Recommended Action Examine the system services control point (SSCP) host VTAM console for status of the specified PU and LU. Review the VTAM console log output for relevant events (such as deactivation of the PU or LU). If, after VTAM console review, the cause is still unknown, report this error to your technical support representative. A temporary workaround is simply to recycle the affected LU at the VTAM console. This will put the LU back into normal circulation.
Error MessageExplanation No SDT (Start Data Transfer) TIMING-MARK response was received by TN3270 server from the TN3270 client software for the specified TN3270 session. If the condition persists for another 2 minutes, the LU is declared bad. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.
Recommended Action Some TN3270 clients may not fully handle the TN3270 RFCs. Enable the client-side trace to figure out on what the client is failing. Replace the failing client software with software from the list of TN3270 software types that are known to work with the TN3270 server (see your technical representative for this). If the problem persists, report this error to your technical support representative.
Error MessageExplanation No response to an UNBIND request was received by the TN3270 server within 30 seconds of sending the request to the host. If this condition persists for another 2 minutes, the current TN3270 session connected to the LU is disconnected. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening-point are in use.
Recommended Action Examine the system services control point (SSCP) host VTAM console for status of the specified PU and LU. Review the VTAM console log output for relevant events (such as deactivation of the PU or LU). If, after VTAM console review, the cause is still unknown, report this error to your technical support representative. A temporary workaround is simply to recycle the affected LU at the VTAM console. This will put the LU back into normal circulation.
Error MessageExplanation No UNBIND TIMING-MARK response was received by TN3270 server from the TN3270 client software for the specified TN3270 session. If the condition persists for another 2 minutes, the LU is declared bad. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.
Recommended Action Some TN3270 clients may not fully handle the TN3270 RFCs. Enable the client-side trace to figure out on what the client is failing. Replace the failing client software with software from the list of TN3270 software types that are known to work with the TN3270 server (see your technical representative for this). If the problem persists, report this error to your technical support representative.
Error MessageExplanation The Route Processor (RP) requested an update or delete action on a physical unit (PU) resource reported as stale or incorrect by the CIP TN3270 server.
Recommended Action Reload the CIP microcode. If the problem recurs, copy the error message exactly as it appears. Run and record the output from the following commands on each CIP in the router before reloading the CIP microcode:
Report this message to your technical support representative.
Error MessageExplanation A Telnet session that failed to negotiate TN3270/TN3270E within a time period was disconnected.
Recommended Action Try to locate the TN3270 client that caused the problem. There could be a bug in the client or it could be a transient network problem.
Error MessageExplanation An unexpected LU-LU session sequence was received. The LU was presented to the LU named by the LOCADDR and PU. The error will cause a negative response of sense code X2001 to send to the host.
Recommended Action Examine the system services control point (SSCP) host VTAM console for status of the specified LU. Get a trace output for the specified LU and report this problem to your technical support representative.
Error MessageExplanation A WSF 3270DS Write with wrong data length was received.
Recommended Action Examine what application in the host sends this WSF, and report this problem to your technical support representative.
Error MessageExplanation A PU sent a request to the host but did not get a response in 30 seconds.
Recommended Action Check to see if the PU is still in ACT/BUSY state. Examine to see if the VTAM can talk to the PU. Check the LLC2 connection.
Error MessageExplanation An internal error occurred while setting the transmit window size on TCP session, so the session is using a default window size.
Recommended Action Report this message to your technical support representative. Also send your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem.
Error MessageExplanation The TN3270 server failed to start correctly, and is now not running. The immediately preceding error messages point to the cause of the failure.
Recommended Action Review the previous error messages to discover what caused the start failure, and take action based on those messages.
Error MessageExplanation This is an informational message announcing the bringing up of the TN3270 server subsystem.
Recommended Action No action is required.
Error MessageExplanation The shutdown of TN3270 server was not finished when a new reincarnation was attempted.
Recommended Action If this problem is caused by a quick restart of the TN3270 server, try to restart the TN3270 server. Report this message to your technical support representative. Also send your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem.
Error MessageExplanation This is an informational message announcing the shutdown of the TN3270 server subsystem.
Recommended Action No action is required.
Error MessageExplanation Initialization of Telnet component of TN3270 server failed.
Recommended Action This is most probably because of inadequate memory on the CIP card. Check the memory, and report this message to your technical support representative.
Error MessageExplanation The TN3270 server received a configuration command from the Cisco IOS newer than CIP expects. Some functionality may not be implemented.
Recommended Action Check that the Cisco IOS version is compatible with the CIP version.
Error MessageExplanation This could either be a transient network problem or an internal error in server.
Recommended Action Ensure that LU outbound pacing is configured. If that is correct, try to locate the TN3270 client that caused the problem. There could be a bug in the client. Also, try to get a Telnet trace of the session by reproducing the problem. Report this error to your technical support representative.
Error MessageExplanation A SNA message from the host is invalid.
Recommended Action If it only happens once, this could be a glitch in the line. Record the message for later reference. If this error recurs, check if the host is configured correctly.
CIP error message related to Channel Adapter utilities
Error MessageExplanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
|
|