CIP-LOADER Error Messages
CIP-LOVE Error Message
CIP-MBUF Error Messages
CIP-MEMD Error Messages
CIP-MPC Error Messages
CIP-MSG802 Error Messages
CIP-NEVADA Error Messages
CIP-OFFL Error Messages
CIP-SCB Error Messages
CIP-SCHED Error Messages
CIP-SLC Error Messages
CIP-SLCI Error Messages
CIP-SSI802 Error Messages
CIP-SUBSYS Error Messages
CIP-SYS Error Messages
CIP-SYSMGT Error Messages
CIP-TN3270 Error Messages
CIP-UTIL Error Message

CIP-LOADER Error Messages

CIP error messages related to the relocating loader facility

Error Message   
%LOADER-3-ABSERR : Error: not handled - Symbol [chars] is absolute

Explanation    The loader does not handle variables of this type.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-ALOCER1 : Error: Allocating storage - load fails

Explanation    There is not enough storage to load this file.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative. More storage will probably be needed. You might use the current storage more efficiently by running a different combination of features.

Error Message   
%LOADER-3-ALOCER2 : Error: Did not allocate storage - loading of data failed

Explanation    There is not enough storage to load this file.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative. More storage will probably be needed. You might use the current storage more efficiently by running a different combination of features.

Error Message   
%LOADER-3-ATFERR : Error: atf array overflow

Explanation    The area to free (ATF) array is too small. The ATF array is an array of areas to be freed when an attempted load fails.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-BADSHT : Error: Section header type [hex]([dec]) not understood

Explanation    The input file is not in the proper format.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-BADVERS : [chars]: Invalid segment version: [chars]

Explanation    The segment version does not match the remainder of the currently loaded software.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-BAKEXP : Error: Deleting external symbol [chars] from the exported table

Explanation    The symbols should have been deleted from the table, but were not. This will probably cause problems during future file loads.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-BIGEND : Error: Input is not big endian

Explanation    The input file is not the correct type for loading.

Recommended Action    Check the input file type. If the file type is correct, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-BINDERR : Error: Bind value in symbol table entry not understood

Explanation    The loader cannot handle variables of this type.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-COMERR : Error: type not handled, must be .scommon

Explanation    The loader cannot handle this type.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-COMMIX : Error: common variable [chars] matches name of non-common loaded variable

Explanation    An error occurred in the input files.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-COMPER : Error: Compiled for incorrect target machine

Explanation    The input file is not the correct type for loading.

Recommended Action    Check the input file type. If the file type is correct, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-DREADE : Error: Reading in program data

Explanation    An error prevented the loader from reading a section of the file.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-DUPEXP : Error: Duplicate exported external symbol [chars] not allowed

Explanation    The file being loaded attempted to export a symbol that had already been exported by a previously loaded file.

Recommended Action    There is a conflict between loadable files and/or the kernel. Report this error to your technical support representative.

Error Message   
%LOADER-3-EIDENT : Error: File header has unknown data in e_ident area

Explanation    The input file is not in the correct format needed for loading.

Recommended Action    Check the input file format. If the format is correct, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-ELF32 : Error: Input is not an ELF32 file

Explanation    The input file is not in the correct format needed for loading.

Recommended Action    Check the input file format. If the format is correct, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-ELFH : Error: Cannot read ELF header from input file

Explanation    The loader could not read the module header information.

Recommended Action    Check the file. If it is correct, report this error message to your technical support representative.

Error Message   
%LOADER-3-ERR16H : Error: processing HI16 LO16 pair. Low without High

Explanation    The loader cannot handle relocation entries of this type.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-ERRCNR : Error: Cannot relocate - required symbol [chars] is not resolved

Explanation    A required symbol is missing.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-FCLOSE : Warning: File close failed, code = [dec]

Explanation    Loading is complete, but the close failed.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-FILESIZE : Unable to access image file

Explanation    The CIP has failed to access necessary image files.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-FOPEN : Error: Cannot open the input file [chars]

Explanation    An error occurred when attempting to open a file to be loaded.

Recommended Action    Confirm that the file exists. Create it if possible. If the problem persists, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-FOPENBZ : Cannot open [chars] - busy (code [dec]), have tried every 5 secs for a minute

Explanation    A required file is currently in use. An open was retried every 5 seconds for 1 minute, before failing the open.

Recommended Action    Report this error to your technical support representative, if open fails.

Error Message   
%LOADER-3-FOPENER : Error: file ([chars]) open failure code [dec]

Explanation    A required file cannot be opened.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-FREADE : Error: reading, offset: [hex] size: [hex]([dec])

Explanation    The loader could not read the input file. The load failed.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-GPPROB : Error: Allocation of GP relative space problem: [hex]([dec]) left, [hex]([dec]) needed

Explanation    The space needed for the allocation of a larger area has been exhausted.

Recommended Action    Sufficient space should be allocated in advance. Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-GREADE : Error: reading in GP relative section data

Explanation    An error prevented the loader from reading a section of the file.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-HDRSIZ : Error: this size header entry cannot be handled

Explanation    The file is not in the proper format. The loader cannot handle it.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-HDRVER : Error: Input is not current version

Explanation    The input file is not the correct version of object file format.

Recommended Action    Check the file format version. If the file version is correct, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-0-HEADER : Loading file [chars]:

Explanation    This message precedes other messages relating to loading a file. It is a header to identify the name of the file being loaded.

Recommended Action    Copy this message and the following messages. Report this information to your technical support representative.

Error Message   
%LOADER-3-HREADE : Error: Cannot read headers from the file

Explanation    An error occurred while reading the file headers.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-INSUFF : Error: insufficient space for suballocation: [hex]([dec]) left, [hex]([dec]) needed

Explanation    There is not enough space for the new allocation.

Recommended Action    Sufficient space should be allocated in advance. Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-0-INVALIDIOS : IOS version incompatible with CIP - must be at least [dec].[dec]

Explanation    The version of Cisco IOS software is incompatible with this CIP microcode image.

Recommended Action    The Cisco IOS software must be updated to match the CIP version. Report this error to your technical support representative.

Error Message   
%LOADER-6-LOADING : [chars] -- [dec] bytes

Explanation    The CIP successfully loaded a segment image.

Recommended Action    This is an informational message only. No action is required.

Error Message   
%LOADER-0-LOADMAP_DATA1 : Ver: [chars] Rev: [dec] Segment: [chars]

Explanation    This message identifies the segment whose section information follows.

Recommended Action    Report this information to your technical support representative.

Error Message   
%LOADER-0-LOADMAP_DATA2 : [hex] [hex] [dec] [chars]

Explanation    This message provides data for addresses, sizes, and so on, of modules loaded into the CIP storage.

Recommended Action    Report this information to your technical support representative.

Error Message   
%LOADER-0-LOADMAP_DATA3 : [chars]

Explanation    This message displays the compile information for the segment listed in the previous line.

Recommended Action    Report this information to your technical support representative.

Error Message   
%LOADER-0-LOADMAP_EMPTY1 : Loader initialization is not complete, no segments loaded

Explanation    The loader has not been initialized. Therefore, no modules are loaded in CIP storage.

Recommended Action    Report this information to your technical support representative.

Error Message   
%LOADER-0-LOADMAP_EMPTY2 : No segments have been loaded

Explanation    The loader has not loaded any modules into CIP storage.

Recommended Action    Report this information to your technical support representative.

Error Message   
%LOADER-0-LOADMAP_HEAD0 : Segment Load Map

Explanation    This message precedes and introduces data listing the map of modules loaded into CIP storage. It also acts as a header for the displayed data.

Recommended Action    Copy the error message and the lines of data. Report this information to your technical support representative.

Error Message   
%LOADER-0-LOADMAP_HEAD1 : Start End Size Name

Explanation    This message precedes and introduces data listing the map of modules loaded into CIP storage. It also acts as a header for the displayed data.

Recommended Action    Copy the error message and the lines of data. Report this information to your technical support representative.

Error Message   
%LOADER-3-LOADRC : Error: Return code is [hex]([dec])

Explanation    This message displays the error level on the load failure.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-MAXRSE : Error: too many Resident Symbol Tables

Explanation    MAX_RSE_TABS is not sufficient to handle this file.

Recommended Action    MAX_RSE_TABS must be increased, and the loadrel.c file must be recompiled. Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-MAXSEC : Error: Total number of sections has exceeded pre-allocated space for [dec] entries

Explanation    MAX_SECTION_COUNT is not sufficient to handle this file.

Recommended Action    MAX_SECTION_COUNT must be increased, and the loadrel.c file must be recompiled. Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-MAXSTRT : Error: Too many string tables

Explanation    MAX_STR_TABS is not sufficient to handle this file.

Recommended Action    MAX_STR_TABS must be increased, and the loadrel.c file must be recompiled. Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-MAXSYMT : Error: Too many symbol tables

Explanation    MAX_SYM_TABS is not sufficient to handle this file.

Recommended Action    MAX_SYM_TABS must be increased, and the loadrel.c file must be recompiled. Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-NOBITS0 : Error: NOBITS but size [dec] is not 0, not understood

Explanation    Either the loader cannot process the input file, or the file is not in the proper format.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-NODSO : Error: section contains dynamic shared objects

Explanation    The input file cannot have dynamic shared objects.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-NOELF : Error: Input is not an ELF file

Explanation    The input file is not in the correct format.

Recommended Action    Check the input file format. If the format is correct, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-NOERES : Error: Could not resolve external symbol [chars]

Explanation    A reference from the file being loaded to an external symbol cannot be resolved.

Recommended Action    Define all prerequisite external symbols before loading the file. If problems persist, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-NOPREFIX : Unable to determine microcode image name

Explanation    The CIP is unable to compose the microcode image name.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-NOPRG : Error: No code to handle program headers

Explanation    The input file is not in the correct format.

Recommended Action    Check the input file format. If the format is correct, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-NOSECH : Error: No section headers to process

Explanation    The input file is not in the proper format.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-NOSO : Error: section contains symbols conflicting with shared objects

Explanation    The input file cannot have shared objects.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-NOTRE : Error: File is neither relocatable nor executable

Explanation    The input file is not in the correct format.

Recommended Action    Check the input file format. If the format is correct, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-NOVERS : [chars]: No entry for loader_segment_version

Explanation    The loader requires a file to be loaded to have an entry, loader_segment_version, containing a specific structure.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-READERR : Error: file read failure code [dec]

Explanation    An error occurred while the file was being read.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-RELFLG : Error: Cannot handle the flags in the relocation entry

Explanation    The loader cannot handle relocation entries of this type.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-RELREAD : Error: Cannot read relocation entries

Explanation    The loader could not read part of the file.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-RELTYP : Error: relocation type [hex]([dec]) not recognized

Explanation    The loader cannot handle this type of relocation.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-RELTYP2 : Error: relocation type R_MIPS_[chars] not handled

Explanation    The loader cannot handle this type of relocation.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-RESERR : [chars] [dec] external symbols cannot be resolved

Explanation    Either the prerequisite files are not loaded, or there are incorrect references.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-SECERR : Error: Cannot handle section [chars]

Explanation    The loader cannot process this type of section of the code.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-SEEKER : Error: file seek failure code [dec]

Explanation    An error occurred positioning within the file.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-SHFLAGE : Error: no storage allocated - sh_flags did not indicate how

Explanation    The loader cannot handle this file.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-SHNHIPE : Error: not handled -End appl specific range of indices

Explanation    The loader cannot handle variables of this type.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-SHNHIR : Error: not handled - End reserved range of indices

Explanation    The loader cannot handle variables of this type.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-SIZERR1 : Error: common variable [chars] has a size incompatible with loaded variable

Explanation    The loader cannot allocate a larger variable to an already loaded smaller variable.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-SORBER : Error: type not handled, must be .sdata or .sbss

Explanation    The loader cannot handle this type.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-SREADE : Error: Cannot read in symbol string

Explanation    The loader could not read a needed section of the file.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-SREADS : Error: Cannot read in symbol table

Explanation    An error prevented reading a necessary part of the file for loading.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-STOTHER : Error: Problem: a symbol table entry is using field ST_OTHER

Explanation    The loader cannot handle this file.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-STREXE : Error: Strings exceed string table area allocated [dec] [dec]

Explanation    The preallocated area is not large enough.

Recommended Action    The loader must be recompiled with more area. Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-SUNDERR : Error: not handled - Small undefined symbol

Explanation    The loader cannot handle variables of this type.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-SYMEXE : Error: Symbols exceed symbol table area allocated [dec] [dec]

Explanation    The preallocated area is not large enough for loading.

Recommended Action    The loader must be recompiled with more area. Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-SYRERR : Error: Relocation entry symbol, [hex]([dec]), is not in symbol table

Explanation    This is an error in the input file.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-TSHSIZ : Error: total sections headers [hex]([dec]) too large for pre-allocated area [hex]([dec])

Explanation    The preallocated area is not large enough for loading.

Recommended Action    The loader must be recompiled with more area. Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%LOADER-3-TYPERR : Error: Type value in symbol table entry not understood

Explanation    The loader cannot handle variables of this type.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-USRERR : Error: not handled - Undefined section reference

Explanation    The loader cannot handle variables of this type.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-VARHIP : Error: Symbol is HIPROC variable - not handled

Explanation    The loader cannot handle variables of this type.

Recommended Action    Report this error to your technical support representative.

Error Message   
%LOADER-3-VARLOP : Error: Symbol is LOPROC variable - not handled

Explanation    The loader cannot handle variables of this type.

Recommended Action    Report this error to your technical support representative.

CIP-LOVE Error Message

CIP error message related to the mechanism that sends statistics from the CIP to the router

Error Message   
%LOVE-3-LOVELETTER : Error in love letter processing

Explanation    An attempt was made to transfer statistics to the RP. The DMA routines returned the wrong transfer request.

Recommended Action    The CIP has recovered. Report this error to your technical support representative.

CIP-MBUF Error Messages

Memory buffer error messages

Error Message   
%MBUF-0-MFREEx2 : mfree: mbuf [hex] already free'ed from pc=[hex] ra=[hex] @(pc=[hex]ra=[hex])

Explanation    A request was made to free an mbuf that was already free.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MBUF-0-PANIC : panic[[chars]@[dec]] in [chars]: [chars]

Explanation    An unexpected internal error has occurred in the TCP/IP stack.

Recommended Action    Report this error to your technical support representative.

CIP-MEMD Error Messages

CIP error message related to the memory device facility

Error Message   
%MEMD-3-BADIPC : IPC message received with no IPC handler

Explanation    An IPC message was queued to the CIP and there was no handler defined to process it.

Recommended Action    The CIP dropped the IPC message. Report this error to your technical support representative.

Error Message   
%MEMD-3-BADPTR : Bad pointer in MEMD. Code: [hex]. ICB: [hex] Header: [hex], Data: [hex]

Explanation    While processing a buffer queue in MEMD, a pointer was found to have an invalid value.

Recommended Action    The CIP dropped the packet. Report this error to your technical support representative.

Error Message   
%MEMD-3-BADVCN : Bad vcn [dec]([hex]), port adapter [dec], MSGDEF_LIMIT_MEDIUM

Explanation    A packet was queued to the CIP and the virtual circuit associated with the packet is not valid.

Recommended Action    The CIP dropped the packet. Report this error to your technical support representative.

Error Message   
%MEMD-3-FRAME_DATA1 : [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex], MSGDEF_LIMIT_MEDIUM

Explanation    This message contains a hex dump of data associated with the immediately preceding error message.

Recommended Action    Forward a copy of the entire hex dump to your Cisco technical support representative.

Error Message   
%MEMD-3-FRAME_DATA2 : [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex], MSGDEF_LIMIT_MEDIUM

Explanation    This message contains a hex dump of data associated with the immediately preceding error message.

Recommended Action    Forward a copy of the entire hex dump to your Cisco technical support representative.

Error Message   
%MEMD-3-FRAME_START : Start address of bad frame: 0x[hex] dumping from 0x[hex], MSGDEF_LIMIT_MEDIUM

Explanation    This message contains the start address of a data frame with a bad virtual circuit number.

Recommended Action    Forward a copy of this message to your Cisco technical support representative.

Error Message   
%MEMD-3-VCNDEREGISTER : Invalid VCN ([dec]) specified

Explanation    When attempting to deregister a routine to handle data for a given virtual circuit, the virtual circuit number was out of range. The deregistration request is ignored.

Recommended Action    Restart the CIP. Report this error to your technical support representative.

Error Message   
%MEMD-3-VCNREGISTER : Invalid VCN ([dec]) specified

Explanation    When attempting to register a routine to handle data for a given virtual circuit, the virtual circuit number was out of range. No messages for the given virtual circuit will be accepted, and additional error messages will be generated for each message.

Recommended Action    Restart the CIP. Report this error to your technical support representative.

Error Message   
%MEMD-3-WRONGINT : VCN [dec]([hex]) not for port adapter [dec], MSGDEF_LIMIT_MEDIUM

Explanation    A packet has been queued for the CIP with a valid virtual circuit number, but the virtual circuit number is associated with the other port adapter.

Recommended Action    The CIP dropped the packet. Report this error to your technical support representative.

CIP-MPC Error Messages

MultiPath Channel error messages

Error Message   
%MPC-6-BAD_DIRECTION : PA[dec] MPC [hex]-[hex] configured for [chars]

Explanation    This informational message is given when an XID2 message specifies a subchannel read/write transfer direction differently from the direction configured.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-3-BAD_DLC_CMD : Received MPC DLC command [hex] unrecognized

Explanation    This error message is given when an MPC DLC frame is received and the DLC command is not recognized.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-3-BAD_FLAGS : Received MPC frame with invalid flags [hex]

Explanation    This error message is given when an MPC block is received and the header configuration is not recognized.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-3-BAD_HDR : Unrecognized MPC header received [hex] [hex]

Explanation    This error message is given when an MPC block is received and the header configuration is not recognized.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-3-BLOCK_SEQ_ERROR : Block rcvd with seq num [hex], expected [hex]

Explanation    This error message is given when an MPC block is received with a sequence number error.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-6-INIT : PA[dec] MPC [hex]-[hex] Device initialized

Explanation    This informative message is given when an MPC device is initialized. The device string is in the form PA x MPC yyyy-zz, where x is the port adapter number, yyyy is the path and zz is the device number.

Recommended Action    No action is required.

Error Message   
%MPC-3-LENGTH_ERR : Inconsistent length in received MPC frame

Explanation    This error message is given when an MPC frame is received with a length value that is inconsistent with the channel block length.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-6-LINK_CONFIGURED : Link [chars] already configured

Explanation    This informative message is given when an attempt is made to configure an MPC link that has already been configured.

Recommended Action    No action is required.

Error Message   
%MPC-6-NODE_NOT_ACTIVE : PA[dec] MPC [hex]-[hex] Rcvd TG data but TG not active

Explanation    This informative message is given when a message if received for an MPC link where the transmission group has not been configured.

Recommended Action    No action is required.

Error Message   
%MPC-0-NOMEM : [chars] Attempt to acquire memory failed, pc: [hex]

Explanation    This error message is given when a call to create a pool or get a buffer fails.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-3-PARTNER_FSM_ERR : TG Name: [chars], Event [chars], State [chars]

Explanation    This error message is given when an internal state machine attempts to execute an event inconsistent with the state.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-6-SEQ_NUM_WRAP : Sequence number from host wrapped. TG name [chars]

Explanation    This informative message is given when the sequence number in a block from the host has wrapped.

Recommended Action    No action is required.

Error Message   
%MPC-6-SHUTDOWN : PA[dec] MPC [hex]-[hex] Device shutdown

Explanation    This informative message is given when an MPC device is shut down. The device string is in the form PA x MPC yyyy-zz, where x is the port adapter number, yyyy is the path and zz is the device number.

Recommended Action    No action is required.

Error Message   
%MPC-3-SUBCH_FSM_ERR : PA[dec] MPC [hex]-[hex] Event [chars], State [chars]

Explanation    This error message is given when an internal state machine attempts to execute an event inconsistent with the state.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-3-SWEEP_FSM_ERR : TG Name: [chars], Event [chars], State [chars]

Explanation    This error message is given when an internal state machine attempts to execute an event inconsistent with the state.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-3-SWEEP_SEQ_ERROR : Sweep rcvd with seq num [hex], expected [hex]

Explanation    This error message is given when an MPC sweep command is received with a sequence number error.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-0-SYSMGT_ERROR1 : MPC Subch detected error in sysmgt call: invalid CMPC DEVICE length

Explanation    An invalid parameter was received in a SYSMGT call.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-0-SYSMGT_ERROR2 : MPC Subch detected error in sysmgt call: invalid operation [dec]

Explanation    An invalid parameter was received in a SYSMGT call.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-0-SYSMGT_ERROR3 : MPC Llcc-Tg detected error in sysmgt call: invalid operation [dec]

Explanation    An invalid parameter was received in a SYSMGT call.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-0-SYSMGT_ERROR4 : MPC Llcc-Tg detected error in sysmgt call: invalid CMPC DEVICE length

Explanation    An invalid parameter was received in a SYSMGT call.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-3-XID2_BAD_DATA : Invalid Xid2 Message: bad length or format

Explanation    This error message is given when an MPC subchannel is in the XID2 exchange state and the message received has a length that is not valid for an XID2 message segment.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-3-XID2_BAD_HDR : Unrecognized Xid2 header received

Explanation    This error message is given when an XID2 frame is received and the header configuration is not recognized.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MPC-3-XID2_FSM_ERR : PA[dec] MPC [hex]-[hex] Event [chars], State [chars]

Explanation    This error message is given when an internal state machine attempts to execute an event inconsistent with the state.

Recommended Action    Report this error to your technical support representative.

CIP-MSG802 Error Messages

CIP 802 error messages related to the IEEE 802.2cx Logical Link Control (LLC) protocol stack

Error Message   
%MSG802-3-ADAPTER_LIMIT_EXCEEDED : Configuration for adapter [dec] [sci_notation] rejected

Explanation    An attempt was made to configure more than 18 CSNA adapters. A maximum of 18 CSNA adapters are allowed per CIP.

Recommended Action    Reduce the number of CSNA adapters configured to comply with the 18 CSNA adapter limit.

Error Message   
%MSG802-6-ADAPTER_OPEN : Adapter [chars]/[int] now open

Explanation    This is an informative message given for bringing up each adapter specified.

Recommended Action    No action is required.

Error Message   
%MSG802-6-ADAPTER_REM : Adapter [chars]/[int] now removed

Explanation    This is an informative message given for removing each adapter specified.

Recommended Action    No action is required.

Error Message   
%MSG802-6-ADAPTER_UPD : Adapter [chars]/[int] LLC parm now altered

Explanation    This is an informative message given for changing the LLC parameters for each adapter specified.

Recommended Action    No action is required.

Error Message   
%MSG802-6-BADNS_WARN : INVALID NS detected [dec] times; tuning of LLC parameter may be needed !!!

Explanation    The LLC protocol stack has received a bad frame that contains an invalid Ns from its peer. The problem is often caused by mis-configuration of LLC parameters. Fine tuning of the LLC parameters of the CIP adapter and its peer might be required to correct this problem. This warning message is only displayed for every 500 occurrences of BAD Ns detected for the given connection.

Recommended Action    Fine tuning of the LLC parameters of CIP adapter and its peer might be required to correct this problem.

Error Message   
%MSG802-6-CTASET_FAIL : set cta max_conn [dec] failed ([dec] bytes free) - max conn remain at [dec]

Explanation    This message means that the CTA mapper is not able to honor the maximum connection as configured, most likely because of running out of resources (such as a shortage of memory). Any attempt to decrease the maximum connection will be rejected. It might be rejected by the mapper because of lack of memory.

Recommended Action    Verify if overconfigured by checking the maximum numbers of connections configured. If not, report this error to your technical support representative.

Error Message   
%MSG802-6-FRAMESZ_EXCEEDED : frame exceeded max size ([dec] bytes)

Explanation    The MEMD buffer currently supported a maximum frame size of 4472 bytes. CSNA detected that the frame sent is larger than what it should be and the frame was discarded. This error most likely occurred because the maximum frame length is misconfigured.

Recommended Action    Check the maximum frame length configured.

Error Message   
%MSG802-3-HARD_ERROR : [chars]

Explanation    The protocol stack encountered error conditions that prevent it from continuing its normal operations.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MSG802-3-INVALID_CFGCMD : invalid config cmd detected cmd=[dec]

Explanation    The LLC task detected an invalid configuration command. The command is rejected.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MSG802-6-INVALID_ID : [chars]: invalid id type = [hex]

Explanation    The LLC has received an invalid ID type. Currently, such an ID type is not supported. The request is discarded.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MSG802-3-INVALID_MSICMD : invalid msi cmd detected cmd=[dec]

Explanation    The LLC task detected an invalid MSI command. The request is discarded.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MSG802-6-INVALID_PRIMITIVE : [chars]: invalid primitive code = [hex]

Explanation    The LLC has received an invalid service primitive. The module and routine that received such a primitive and the Service Primitive code are displayed.

Recommended Action    This is not a fatal error and the CSNA should be able to continue to operate. If somehow, the error becomes disruptive, report this error to your technical support representative.

Error Message   
%MSG802-3-INVALID_VCN1 : LAN not configured for vcn=[dec], adapter=[dec], lan=[dec], ran=[dec] - cfg cmd rejected

Explanation    Unable to process the configuration command because an invalid VCN was detected. The configuration command is rejected.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MSG802-3-INVALID_VCN2 : LAN has configured for vcn=[dec], adapter=[dec], lan=[dec], ran=[dec] - cfg cmd rejected

Explanation    Unable to process the configuration command because an invalid VCN was detected. The configuration command is rejected.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MSG802-6-LLC_DUP_CCB : LLC Station : RMAC=[hex].[hex].[hex] LMAC=[hex].[hex].[hex] LSAP=[hex] RSAP=[hex]

Explanation    An open station was received but the station address is already open.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MSG802-6-LLC_DUP_SAP : LLC Duplicate SAP on interface [int] : SAP=[hex], new user([hex]) old user([hex])

Explanation    Two SAP users have tried to open the same SAP number on the same adapter. A SAP user may be an XCA Major Node, a TN3270 Server PU, or TN3270 Server DLUR.

Recommended Action    Check XCA Node definitions.

Error Message   
%MSG802-6-LLC_SHUT : LLC shutdown completed

Explanation    This is an informative message given for shutdown of the LLC. Both the LLC MEMD READ/WRITE task and the TIMER task were taken down.

Recommended Action    No action is required.

Error Message   
%MSG802-6-LLC_START : Starting LLC-2 with a session capacity of [int]

Explanation    This is an informative message given for bringing up an LLC subsystem.

Recommended Action    No action is required.

Error Message   
%MSG802-6-MAX_FAILED : change max conn [dec] failed ([dec] bytes free) - max conn remain at [dec]

Explanation    This message means that CIP is not able to honor the maximum connection as configured, most likely because of running out of resources (such as shortage of memory). Any attempt to decrease the maximum connection will be rejected. It might be rejected by the mapper because of lack of memory.

Recommended Action    Verify if overconfigured by checking the maximum numbers of connections configured. If not, report this error to your technical support representative.

Error Message   
%MSG802-6-MAX_FAILED2 : cipmsg pool empty - max conn remain at [dec]

Explanation    This message means that CIP is not able to honor the maximum connection as configured, because it was unable to allocate a MSG buffer from the CIPMSG pool.

Recommended Action    Enter the max_llc command again. If the error persists, report this error to your technical support representative.

Error Message   
%MSG802-6-MAX_LLC_EXCEEDED : MAX_LLC_SESSIONS([int]) exceeded - [int] sessions rejected

Explanation    The maximum number of concurrent LLC connections has been exceeded.

Recommended Action    Increase the MAX_LLC_SESSIONS parameter on the CIP virtual interface.

Error Message   
%MSG802-3-ODD_MEMD : Odd boundary memd buffer; memd_addr=[hex]

Explanation    MEMD should never be in an odd boundary. This check is added to detect any possible run-time errors.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MSG802-3-QUEUE_OPEN : [chars]

Explanation    The LLC task detected a queue open failure. Most likely the resource is not available for such a request.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MSG802-3-RESOURCE_DEPLETED : [chars]

Explanation    The protocol stack encountered error conditions that prevent it from continuing its normal operations. Possible error such as resource depletion.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MSG802-6-SHRINK_CONN : reducing max_conn doesn't take effect until the virtual interface is restarted - max conn remain at [dec]

Explanation    This is an informative message given for reduce max_conn. Reducing the max_conn is not allowed for this release.

Recommended Action    No action is required.

Error Message   
%MSG802-6-SHUT_IN_PROG : shutdown in progress ... [chars] command rejected

Explanation    This message means that LLC is in shutdown cleanup state. All configuration commands are subsequently rejected.

Recommended Action    Retry the command when the LLC is in operational state.

Error Message   
%MSG802-6-START802_FAILED : unable to start 802 for [dec] connections - Memory Avail = [dec] bytes

Explanation    This message means that CIP is not able to bring up the CTA 802 task, most likely because it is running out of resources (such as shortage of memory).

Recommended Action    Verify if overconfigured. Check the maximum number of connections configured. Report this error to your technical support representative.

Error Message   
%MSG802-3-UNKNOWN_EVENT : detect unknown event; event=[dec]

Explanation    The LLC task detected an unknown event.

Recommended Action    Report this error to your technical support representative.

Error Message   
%MSG802-3-UNSUPPORTED : [chars]

Explanation    The LLC task detected an unsupported function being requested. The request is voided.

Recommended Action    Report this error to your technical support representative.

CIP-NEVADA Error Messages

Error messages related to the CIP interrupt controller

Error Message   
%NEVADA-0-BADADD : Add: Invalid nevada interrupt code [dec]

Explanation    An attempt was made to specify an interrupt handler for an invalid interrupt type on the Nevada interrupt control chip. This is a fatal internal logic error.

Recommended Action    Report this error to your technical support representative.

Error Message   
%NEVADA-0-BADDISABLE : Disable: Invalid nevada interrupt code [dec]

Explanation    An attempt was made to disable an invalid interrupt type on the Nevada interrupt control chip. This is a fatal internal logic error.

Recommended Action    Report this error to your technical support representative.

Error Message   
%NEVADA-0-BADENABLE : Enable: Invalid nevada interrupt code [dec]

Explanation    An attempt was made to enable an invalid interrupt type on the Nevada interrupt control chip. This is a fatal internal logic error.

Recommended Action    Report this error to your technical support representative.

Error Message   
%NEVADA-0-BADENABLE2 : Enable: No interrupt routine for code [dec]

Explanation    An attempt was made to enable an interrupt routine on the Nevada interrupt control chip, but there was no interrupt routine specified. This is a fatal internal logic error.

Recommended Action    Report this error to your technical support representative.

Error Message   
%NEVADA-0-BADINT : Interrupt received with no interrupt routine defined

Explanation    An interrupt was received for a code with no interrupt handler defined. This is a fatal internal logic error.

Recommended Action    Report this error to your technical support representative.

Error Message   
%NEVADA-0-BADREMOVE : Remove: Invalid nevada interrupt code [dec]

Explanation    An attempt was made to remove an interrupt handler for an invalid interrupt type on the Nevada interrupt control chip. This is a fatal internal logic error.

Recommended Action    Report this error to your technical support representative.

CIP-OFFL Error Messages

CIP error messages related to the offload protocol

Error Message   
%OFFL-4-BADDESC : Socket descriptor [dec] in request is bad: state [chars] compare [dec]

Explanation    The host sent a socket request with an invalid socket descriptor. The CIP sent an error response to this socket request. This could be a host error or a CIP internal logic error.

Recommended Action    This message is followed by a dump of the request. Copy the error messages exactly as they appear, and report them to your technical support representative.

Error Message   
%OFFL-3-BADSEQ : Socket request [chars] should be last in sequence

Explanation    The host sent a socket request that should be the last in a sequence but is not. This error is caused either by an internal logic error, or by an incompatibility between the offload code on the mainframe and the offload code on the CIP.

Recommended Action    This message is followed by a hex dump of the offending sequence of offload messages. Copy the error messages exactly as they appear, and report them to your technical support representative.

Error Message   
%OFFL-6-COMMAND : Unrecognized offload command code [dec]. xfer_element = 0x[hex]

Explanation    The host sent an offload command with an invalid offload command code.

Recommended Action    The CIP has ignored the request. Report this error to your technical support representative.

Error Message   
%OFFL-7-HEX16B : [hex]: [hex][hex][hex][hex] [hex][hex][hex][hex] [hex][hex][hex][hex] [hex][hex][hex][hex] [chars]

Explanation    This message contains a hex dump of data associated with the immediately preceding error message.

Recommended Action    Forward a copy of the entire hex dump to your Cisco technical support representative.

Error Message   
%OFFL-7-HEX4W : [hex]: [hex] [hex] [hex] [hex] [chars]

Explanation    This message contains a hex dump of data associated with the immediately preceding error message.

Recommended Action    Forward a copy of the entire hex dump to your Cisco technical support representative.

Error Message   
%OFFL-3-ILLALH : Illegal hdr alignment at 0x[hex], [dec] bytes available

Explanation    An internal logic error occurred. An offload message header crossed a buffer boundary.

Recommended Action    The CIP ignored the request. Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%OFFL-3-ILLEN : Illegal byte count in offload data. [dec] specified, [dec] available. xfer_element = 0x[hex]

Explanation    An internal logic error occurred. The buffer length field in the offload message header does not equal the size of the data buffer.

Recommended Action    The CIP assumes the offload message header contains no data. Copy the error message exactly as it appears, and report it to your technical support representative.

Error Message   
%OFFL-0-ILLFREE1 : SCB chain does not end with a read hdr

Explanation    An internal logic error occurred. A sequence of buffers was attempted to be freed, but was incomplete.

Recommended Action    Report this error to your technical support representative.

Error Message   
%OFFL-0-ILLFREE2 : SCB ends with a read hdr with the MTC bit set

Explanation    An internal logic error occurred. A sequence of buffers was attempted to be freed, but was incomplete.

Recommended Action    Report this error to your technical support representative.

Error Message   
%OFFL-0-ILLINTF : Illegal number of offload interfaces. [dec] specified, [dec] expected

Explanation    The offload initialization code found an internal error.

Recommended Action    Report this error to your technical support representative.

Error Message   
%OFFL-3-ILLRST : Received restart with [dec] intf, [dec] is max. xfer_element = 0x[hex]

Explanation    The host sent an offload restart request with too many defined interfaces.

Recommended Action    The CIP has ignored the request. Check your host configuration for this offload device. Report this error to your technical support representative.

Error Message   
%OFFL-6-LONGREC : Attempt to transmit too large a record

Explanation    The amount of data being read by the channel exceeded the size of the read CCW.

Recommended Action    Report this error to your technical support representative.

Error Message   
%OFFL-3-MISRST : Received restart [chars] with unknown IP [dec].[dec].[dec].[dec]

Explanation    The host sent an offload restart request with an unknown IP address for the API link.

Recommended Action    The CIP has ignored the mismatch. Correct your host configuration for this offload device.

Error Message   
%OFFL-6-MSGLEFT : Type [dec] xfer_element in work queue after shutdown

Explanation    The offload application received a message after a shutdown. This is an internal logic error. The message was ignored.

Recommended Action    Report this error to your technical support representative.

Error Message   
%OFFL-0-NOMBUF : Out of mbuf's for handling socket operations

Explanation    An internal logic error occurred. Not enough memory buffers were allocated to handle the current offload socket operation.

Recommended Action    Report this error to your technical support representative.

Error Message   
%OFFL-3-NOMEM : Not enough memory to start offload tasks

Explanation    Not enough free memory is available to start the TCP/IP offload tasks. The configuration request was ignored.

Recommended Action    Install more memory for the CIP, or configure fewer devices.

Error Message   
%OFFL-0-NOPEND : Trying to free buffer when no send is pending. Operation: [dec]

Explanation    A request to free a send buffer was made even though there is no send pending. This is an internal logic error.

Recommended Action    Report this error to your technical support representative.

Error Message   
%OFFL-6-NOTXBUF : Unable to allocate txbuf

Explanation    No transmit buffers are available for sending a RESTART response.

Recommended Action    Report this error to your technical support representative.

Error Message   
%OFFL-3-PENDREQ : Pending request [hex] deleted due to new request [hex]

Explanation    The offload application had to save a socket request for later execution while another request of the same type was pending. This is an internal logic error. The first request was dropped.

Recommended Action    Report this error to your technical support representative.

Error Message   
%OFFL-3-REJSOCK : Not enough memory to handle new socket. [dec] sockets open. [dec] in holddown

Explanation    Not enough free memory is available to open another socket. The socket request failed.

Recommended Action    Install more memory for the CIP, configure fewer devices, or limit the number of sessions through this offload device.

Error Message   
%OFFL-3-REQFORM : Socket request [dec] uses invalid parameters. Offset [dec]: [hex]

Explanation    The host sent a socket request with an invalid parameter. The CIP sent an error message in response to this request.

Recommended Action    Report this error to your technical support representative.

Error Message   
%OFFL-3-REQLEN : Socket request [dec] has illegal length [dec]

Explanation    The host sent a socket request with an incorrect length. The CIP sent an error message in response to this request.

Recommended Action    This message is followed by a hex dump of the offending offload message. Copy the error messages exactly as they appear, and report them to your technical support representative.

Error Message   
%OFFL-3-REQTYPE : Unknown [chars] socket request code [dec]

Explanation    The host sent a socket request with an unknown type.

Recommended Action    The CIP has ignored the request. Report this error to your technical support representative.

Error Message   
%OFFL-4-SENDERR : Bad serial number [hex] in send request - expected [hex]

Explanation    The host sent a send socket request that had an unexpected serial number in the header. This is most likely a bug on the host.

Recommended Action    The CIP sent an error response to the send socket request. The host TCP/IP stack will probably print the error message, "Unexpected result from Offload device...." Copy the error messages exactly as they appear, and report them to your technical support representative.

Error Message   
%OFFL-4-SOCLEFT : [dec] Sockets found after shutdown

Explanation    When the offload application quit, it detected sockets that were still waiting for cleanup. This is an internal logic error.

Recommended Action    This message should be preceded by other error messages that provide further information. Copy the error messages exactly as they appear, and report them to your technical support representative.

Error Message   
%OFFL-6-SOCREQ : Unrecognized socket request code [dec]

Explanation    The host sent a socket request with an invalid code.

Recommended Action    The CIP has ignored the request. Report this error to your technical support representative.

Error Message   
%OFFL-6-UNEXP : Unexpected offload command code [dec]

Explanation    An internal logic error occurred. The request type in the offload message was valid, but unexpected.

Recommended Action    The CIP has ignored the request. Report this error to your technical support representative.

Error Message   
%OFFL-6-VIRTOFFL : offload device may not be created on a virtual port adapter

Explanation    An attempt was made to configure an offload device on the virtual port adapter. Offload devices are permitted on physical port adapters only.

Recommended Action    The configuration request was ignored. No action is required.

Error Message   
%OFFL-6-WRCHAIN : Received too long message, xfer_element 0x[hex] chains to 0x[hex]

Explanation    The offload application received a message consisting of more than one xfer_element. This is currently not supported.

Recommended Action    Report this error to your technical support representative.

Error Message   
%OFFL-4-WRONGDESC : Wrong descriptor type in purge request, descriptor [hex] [chars]found (position [dec])

Explanation    The host sent a purge socket request that contained the host descriptor instead of the offload box descriptor. This is most likely a bug or an obscure feature on the host.

Recommended Action    If the CIP found the specified host descriptor, it processed the purge request. Otherwise, it ignored it. Copy the error messages exactly as they appear, and report them to your technical support representative.

Error Message   
%OFFL-0-WRONGFREE : Trying to free mbuf out of sequence

Explanation    An internal logic error occurred. An unexpected address was specified in a request to free a buffer

Recommended Action    Report this error to your technical support representative.

Error Message   
%OFFL-3-WRONGLINK : Trying to send mbuf on CLAW control link

Explanation    An attempt was detected to send a packet in an mbuf on CLAW link 0. This is an internal logic error. The packet was ignored.

Recommended Action    Report this error to your technical support representative.

CIP-SCB Error Messages

CIP error messages related to the storage control block

Error Message   
%SCB-6-BADSCB : Request to free SCB 0 ignored

Explanation    An attempt was made to free SCB 0. This is an internal logic error. The request was ignored.

Recommended Action    Report this message to your technical support representative.

Error Message   
%SCB-6-RESUME : SCB on port [dec] available, correlator: [dec] task: [chars] [hex], MSGDEF_LIMIT_GLACIAL

Explanation    A task waiting for a channel storage control block woke up. This message is typically preceded by the message, "SCB limit on port reached." The correlator value in this message and the following message indicate that the two messages form a pair. In most cases, the pair of messages indicates a burst of activity that resulted in an unusually long queue for the channel.

Recommended Action    This is an informational message. No action is required.

Error Message   
%SCB-6-WAIT : SCB limit on port [dec] reached, correlator: [dec] task: [chars] [hex], MSGDEF_LIMIT_GLACIAL

Explanation    A task tried to allocate a channel storage control block when all blocks were in use. The task is now waiting for a block to become available. This message is typically followed by the message, "SCB on port available." The correlator value in this message and the following message indicate that the two messages form a pair. In most cases, the pair of messages indicates a burst of activity that resulted in an unusually long queue for the channel.

Recommended Action    If this message is followed by any kind of indication that the CIP stopped working properly, report it to your technical support representative, along with the output of the following commands:

In addition, check the multiple virtual storage (MVS) syslog and the TCPIP joblog (or equivalent for other mainframe operating systems) for unusual channel-related messages. Pay particular attention to anything related to TCP/IP offload.

CIP-SCHED Error Messages

Error messages related to the scheduler, the facility responsible for determining which process to run at a given time on the CIP

Error Message   
%SCHED-0-BADPRIORITY : Task priority of [dec] is not allowed.

Explanation    A request was made to create a process, but the priority for the process was not valid. The process was not created.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SCHED-0-INVLOCK1 : Invalid lock word of [dec] used in lock request

Explanation    An attempt was made to request a lock, but the lock word contained invalid data. This is a fatal internal logic error.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SCHED-0-INVLOCK2 : Invalid lock word of [dec] used in unlock request

Explanation    An attempt was made to unlock a lock, but the data in the lock word was not valid. This is a fatal internal logic error.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SCHED-0-NMLDATA : tcb_addr = 0x[hex] current_tcb = 0x[hex] lock_value = [dec]

Explanation    This message contains data that relates to the "SCHED-0-NOTMYLOCK" message.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SCHED-0-NOLOCK : Attempt was made to unlock resource that wasn't locked

Explanation    An attempt was made to unlock a lock that was not held. This is a fatal internal logic error.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SCHED-0-NOPROCID : No process id available for task creation

Explanation    An attempt was made to create more tasks than the CIP is designed to allow. The process was not created.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SCHED-0-NOSTACK : Could not allocate [dec] bytes for stack from SRAM

Explanation    An attempt was made to create a process and not sufficient storage was available to contain the stack for the process. The process was not created.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SCHED-0-NOTCB : Could not allocate [dec] bytes for tcb from SRAM

Explanation    An attempt was made to create a process and sufficient storage was not available to contain the control block for the process. The process was not created.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SCHED-0-NOTMYLOCK : Attempt was made to unlock another task's resource

Explanation    An attempt was made to unlock a lock that was set by another task. This is a fatal internal logic error.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SCHED-0-NOTPROCES : Attempt was made to lock while not at process level

Explanation    An attempt was made to lock while not at the process level. This is a fatal internal logic error.

Recommended Action    Report this error to your technical support representative.

CIP-SLC Error Messages

CIP error messages related to the serial link controller

Error Message   
%SLC-3-PCANMIRESET : Reset of Port [dec] NMI failed

Explanation    After servicing a Non-Maskable Interrupt from a PCA interface, the attempt to reset the interrupt failed.

Recommended Action    Report this message to your technical support representative.

Error Message   
%SLC-3-SCANEP1 : Scan of EP ring 1 failed

Explanation    An attempt to scan the first set of internal latches on the Enterprise Systems Connection (ESCON) processor failed.

Recommended Action    Report this message to your technical support representative.

Error Message   
%SLC-3-SCANEP2 : Scan of EP ring 2 failed

Explanation    An attempt to scan the second set of internal latches on the Enterprise Systems Connection (ESCON) processor failed.

Recommended Action    Report this message to your technical support representative.

Error Message   
%SLC-3-SCANSLC : Scan of SLC ring failed

Explanation    An attempt to scan the internal latches of the serial link controller failed.

Recommended Action    Report this message to your technical support representative.

Error Message   
%SLC-3-STOPBIDITO : Stop BIDI clock timed out

Explanation    An attempt was made to stop the clock on the interface between the Enterprise Systems Connection (ESCON) processor and the serial link controller. The serial link controller did not indicate that the clock was stopped.

Recommended Action    Report this message to your technical support representative.

Error Message   
%SLC-3-STOPEPTO : Stop EP clock timed out

Explanation    An attempt was made to stop the clock on the Enterprise Systems Connection (ESCON) processor. The serial link controller did not indicate that the clock was stopped. The CIP attempted to stop the BIDI clock.

Recommended Action    Report this message to your technical support representative.

CIP-SLCI Error Messages

CIP error messages related to the SLC Interface

Error Message   
%SLCI-3-BAD_TYPE_CODE : PA[dec] MPC [hex]-[hex] got unrecognized xfer_list type code

Explanation    This error message is given when an MPC process receives a xfer_list with an unrecognized type code.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SLCI-3-INBOUND_FSM_ERR : PA[dec] MPC [hex]-[hex] Event [chars], State [chars]

Explanation    This error message is given when an internal state machine attempts to execute an event inconsistent with the state.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SLCI-3-INFLOW_FSM_ERR : PA[dec] MPC [hex]-[hex] Event [chars], State [chars]

Explanation    This error message is given when an internal state machine attempts to execute an event inconsistent with the state.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SLCI-0-NOMEM : Attempt to acquire memory failed, pc: [hex]

Explanation    This error message is given when a call to create a pool or get a buffer fails.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SLCI-0-STASH_ADR_ERR : PA[dec] MPC [hex]-[hex] Stash check failed, mbuf addr [hex] and SCB addr [hex]

Explanation    The error message is given when the internal stash validation fails on mismatch between an mbuf data address and a storage control block (SCB) data address.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SLCI-0-STASH_EMPTY : Stash empty on read complete

Explanation    The error message is given when a read operation completes, but there was no stashed data.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SLCI-0-STASH_MORE_MBUFS : PA[dec] MPC [hex]-[hex] Stash check failed, more mbufs than SCBs

Explanation    The error message is given when the internal stash validation fails because the mbuf chain is longer than the storage control block (SCB) chain.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SLCI-0-STASH_MORE_SCBS : PA[dec] MPC [hex]-[hex] Stash check failed, more SCBs than mbufs

Explanation    The error message is given when the internal stash validation fails because the storage control block (SCB) chain is longer than the mbuf chain.

Recommended Action    Report this error to your technical support representative.

CIP-SSI802 Error Messages

CIP SSI802 error messages related to the common service System Service Interface (SSI) facility

Error Message   
%SSI802-6-DUMP : [chars]

Explanation    This message is used by the dump utility to display the hex dump of storage.

Recommended Action    No action is required.

Error Message   
%SSI802-3-FATAL_ERROR : SSI_ASSERT failure in [chars] @ [int] - [chars]

Explanation    The CSNA encountered unrecoverable error conditions that prevent it from continuing its normal operations.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SSI802-3-RTN_ADR : Return Address: 0x[hex]

Explanation    This is a debug feature to show the return address when an ASSERT is used in an inline function.

Recommended Action    Action according to subsequent error.

CIP-SUBSYS Error Messages

Software subsystem error messages

Error Message   
%SUBSYS-2-BADCLASS : Bad subsystem class ([dec]) - ignoring subsystem

Explanation    A software consistency check failed.

Recommended Action    Call your technical support representative for assistance.

Error Message   
%SUBSYS-2-BADSEQUENCE : Subsystem ([chars]) has cross-class sequence for ([chars])

Explanation    A software consistency check failed.

Recommended Action    Call your technical support representative for assistance.

Error Message   
%SUBSYS-2-BADVERSION : Bad subsystem version number ([dec]) - ignoring subsystem

Explanation    A software consistency check failed.

Recommended Action    Call your technical support representative for assistance.

Error Message   
%SUBSYS-2-MAXRECUR : Too many levels of recursion

Explanation    A software consistency check failed.

Recommended Action    Call your technical support representative for assistance.

Error Message   
%SUBSYS-2-MISMATCH : Kernel and subsystem version differ ([dec].[dec]) - ignoring subsystem

Explanation    A software consistency check failed.

Recommended Action    Call your technical support representative for assistance.

Error Message   
%SUBSYS-2-NOTFOUND : Subsystem ([chars]) needs subsystem ([chars]) to start

Explanation    A software consistency check failed.

Recommended Action    Call your technical support representative for assistance.

CIP-SYS Error Messages

CIP operating system error messages

Error Message   
%SYS-3-BADBLOCK : Bad block pointer [hex]

Explanation    A block of memory is corrupt at the indicated location.

Recommended Action    If this message recurs, call your technical support representative for assistance.

Error Message   
%SYS-3-BADFREEMAGIC : Corrupt free block at [hex] (magic [hex])

Explanation    A block of memory is corrupt at the indicated location.

Recommended Action    If this message recurs, call your technical support representative for assistance.

Error Message   
%SYS-3-BADFREEPTRS : Bad [chars] pointer [hex] at [hex] ([chars] = [hex])

Explanation    A pointer in the block header at the indicated location is corrupt.

Recommended Action    If this message recurs, call your technical support representative for assistance.

Error Message   
%SYS-3-BADMAGIC : Corrupt block at [hex] (magic [hex])

Explanation    The free memory pool is corrupted.

Recommended Action    Call your technical support representative for assistance.

Error Message   
%SYS-2-BADSHARE : Bad refcount in [chars], ptr=[hex], count=[hex]

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, call your technical support representative for assistance.

Error Message   
%SYS-6-BLKINFO : [chars]blk [hex], words [int], alloc [hex], [chars], dealloc [hex], rfcnt [hex]

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, call your technical support representative for assistance.

Error Message   
%SYS-2-FREEBAD : Attempted to free memory at [hex], not part of buffer pool

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, call your technical support representative for assistance.

Error Message   
%SYS-2-FREEFREE : Attempted to free unassigned memory at [hex], alloc [hex], dealloc [hex]

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, call your technical support representative for assistance.

Error Message   
%SYS-3-INUSEFREE : Block [hex] on free list [dec] in use

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, call your technical support representative for assistance.

Error Message   
%SYS-3-INVMEMINT : Invalid memory action ([chars]) at interrupt level

Explanation    This message indicates that a memory allocation or deallocation was attempted from an interrupt handler.

Recommended Action    If this message recurs, call your technical support representative for assistance.

Error Message   
%SYS-2-LOWMEM : Low memory debug exception (limit=[int] free=[int])

Explanation    The CIP is running short on memory.

Recommended Action    It may be necessary to free some memory by exiting a program. If this message recurs, call your technical support representative for assistance.

Error Message   
%SYS-2-MEMTOOSMALL : CIP software requires a minimum of 8MB of DRAM

Explanation    The CIP software has become large enough that it will not run with only 2 MB of DRAM.

Recommended Action    Contact your support representative for a free 8 MB upgrade.

Error Message   
%SYS-6-MTRACE : [chars]: addr, pc ADDRPC ADDRPC ADDRPC ADDRPC ADDRPC ADDRPC ADDRPC ADDRPC

Explanation    The free memory pool is corrupted.

Recommended Action    If this message recurs, contact your technical support representative for assistance.

Error Message   
%SYS-2-NOMEMFRG : Memory fragmentation check debug exception (fragment size [int])

Explanation    The system detected an error while checking memory fragmentation.

Recommended Action    If this message recurs, call your technical support representative for assistance.

Error Message   
%SYS-2-NOMEMORY : No memory available for [chars] [dec]

Explanation    An operation could not be accomplished because of a low-memory condition.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message   
%SYS-3-NZREFCNT : Block [hex] on free list [dec] with ref count [dec]

Explanation    A block of memory in the free pool is actually in use. The number of processes using the memory block is indicated.

Recommended Action    If this message recurs, call your technical support representative for assistance.

Error Message   
%SYS-3-OVERRUN : Block overrun at [hex] (redzone [hex])

Explanation    An internal software error has occurred.

Recommended Action    If this message recurs, contact your technical support representative for assistance.

Error Message   
%SYS-5-RELOAD : Reload requested

Explanation    A reload or restart has been requested.

Recommended Action    This is a notification message only. No action is required.

Error Message   
%SYS-5-RESTART : System restarted --[chars]

Explanation    A reload or restart has been requested.

Recommended Action    This is a notification message only. No action is required.

Error Message   
%SYS-3-WRONGFREELIST : Block [hex], size [dec], on wrong free list ([dec], [dec])

Explanation    A freed buffer has been placed on the wrong list of free buffers.

Recommended Action    If this message recurs, call your technical support representative for assistance.

CIP-SYSMGT Error Messages

CIP error messages related to network management processing for system management remote procedure calls

Error Message   
%SYSMGT_EVENT-4-ERROR : [chars] - [chars]([chars])

Explanation    This message indicates a System Management event sending operation failure. Traps, alerts, and console messages for a channel event will not be generated.

Recommended Action    If this error recurs, report it to your technical support representative.

Error Message   
%SYSMGT_RPC-3-ERROR : Error detected ([chars])

Explanation    A system error has been detected in the Systems Management Remote Procedure Call processing.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SYSMGT_RPC-3-IPC_ERROR : [chars] [chars] failed ([chars]), MSGDEF_LIMIT_GLACIAL

Explanation    This message indicates a System Management Remote Procedure Call operation failure. Request for information from the Channel Adapter card will not be processed.

Recommended Action    Report this error to your technical support representative.

Error Message   
%SYSMGT_RPC-3-NOMEM : [chars]

Explanation    Channel Adapter System Management could not initialize because of a lack of memory available on the Channel Adapter. Since the Channel Adapter SYSMGT component was unable to initialize, most show extended channel command information and all Channel Adapter event notifications will not be available to the user.

Recommended Action    Upgrade the Channel Adapter with more memory.

Error Message   
%SYSMGT_RPC-6-STATE_CHANGE : System Management [chars]

Explanation    The Channel Adapter System Management subsystem has changed state.

Recommended Action    This is an informational message only. No action is required.

CIP-TN3270 Error Messages

Error messages related to the TN3270 server feature of the CIP card

Error Message   
%TN3270S-4-BAD_MAX_LUS_CFG : Could not change maximum LUs to [dec]

Explanation    The TN3270 server could not change the maximum number of LUs to the requested value. The previous number is still in use.

Recommended Action    Review the previous error messages to discover what caused the failure, and take action based on those messages.

Error Message   
%TN3270S-1-CREATE_MUXWAIT_FAILED : A TN3270 server related semaphore could not be created.

Explanation    An important semaphore could not be created.This is either because of memory shortage or some internal code error.

Recommended Action    This is most probably because of insufficient memory on the board. Upgrade your board with additional memory. If you believe sufficient memory is on the board, it is possible that there is a memory leak. Report details of your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem to your technical support representative.

Error Message   
%TN3270S-1-CREATE_POOL_FAILED : A TN3270 server related buffer pool could not be created.

Explanation    An important buffer pool could not be created. This is either because of memory shortage or some internal code error.

Recommended Action    This is most probably because of insufficient memory on the board. Upgrade your board with additional memory. If you believe sufficient memory is on the board, it is possible that there is a memory leak. Report details of your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem to your technical support representative.

Error Message   
%TN3270S-1-CREATE_THREAD_FAILED : A TN3270 server related thread could not be started

Explanation    An important thread could not be created. This is either because of memory shortage or some internal code error.

Recommended Action    This is most probably because of insufficient memory on the board. Upgrade your board with additional memory. If you believe sufficient memory is on the board, it is possible that there is a memory leak. Report details of your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem to your technical support representative.

Error Message   
%TN3270S-4-DDDLU_NOT_SUPPORTED : Host does not support dddlu at IP addr [chars], port [dec], 600*ONESEC

Explanation    TheTN3270 server cannot complete one or more connection requests from a TN3270/E client because the host does not support dynamic definition of dependent LUs (DDDLU).

Recommended Action    Check that all PUs configured for use with DDDLU have the LUGROUP operand defined. Also, check that the specified VTAM LUGROUP major node is active.

Error Message   
%TN3270S-4-FUNC_NEGOT_LOOP : Client [chars]:[dec] in loop on TN3270E function negotiation [dec]., 600*ONESEC

Explanation    The client software is not behaving as per RFC.

Recommended Action    Try to locate the TN3270 client that caused the problem. There could be a bug in the client.

Error Message   
%TN3270S-0-ILLEGAL_CCMUTEX_RELEASE : Releasing unacquired semaphore, lock_held [hex] lock_value [hex] ccMutex tcb [hex] thread tcb [hex]

Explanation    An exclusive lock is being released illegally by the executing thread. The lock is either held by no one or by some other thread.

Recommended Action    To recover, you must microcode reload the CIP. Since this problem is very serious, you might get this error again. In any case, send output of this message and tasks on CIP console to your technical support representative. Also, send your configuration and any action you must do to get this problem.

Error Message   
%TN3270S-4-ILLEGAL_SUBOPTION : Client [chars]:[dec] sent Telnet suboption [dec] illegally

Explanation    The client software is not behaving as per RFC.

Recommended Action    Try to locate the TN3270 client that caused the problem. There could be a bug in the client.

Error Message   
%TN3270S-1-LISTENFAIL : Listening on [hex] [dec] Failed; err [dec]

Explanation    There was an attempt to bring up a PU, but listening on the corresponding TCP/IP port could not be started.

Recommended Action    Check that sufficient memory is present on the CIP card. Report this error to your technical support representative.

Error Message   
%TN3270S-2-LOW_MEM : Insufficient memory for TN3270 server, [dec] KBytes available, [dec] required

Explanation    Insufficient memory prevents proper operation of TN3270 server.

Recommended Action    Ensure that enough memory is available on the board. Upgrade the memory on the board or cancel other services running on the CIP. If you believe sufficient memory is on the board, it is possible that there is a memory leak. Report details of your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem to your technical support representative.

Error Message   
%TN3270S-1-LU_ERROR : lu error [chars]: [chars]:[dec] pu:[hex], tnet:[hex]

Explanation    An unexpected event was presented to the LU named by the LOCADDR and PU. The error may cause the TN3270 session to not work properly. More detail on this error is contained in the "LU_ERROR_INFO" messages immediately following this message.

Recommended Action    Report this problem to your technical support representative.

Error Message   
%TN3270S-1-LU_ERROR_INFO : LU info: Event [chars], state = [hex], snaState = [hex], flag = [hex]

Explanation    This message shows information about the LU state, history, and flags before the error happened.

Recommended Action    Report this problem to your technical support representative.

Error Message   
%TN3270S-1-LU_NO_BUFFER : No buffer for lu: [chars]

Explanation    Some preallocated LU buffers for transmission have run out. The transmission of the message is aborted. The LU session is left incomplete. In addition, the LU session could hang.

Recommended Action    Use the show command to find out as much as possible about the LU state and report the information to your technical support representative.

Error Message   
%TN3270S-6-LU_THRESHOLD : Warning: TN3270 sessions are at [dec]%% of maximum-lus

Explanation    This message indicates that the number of LU sessions is approaching the configured maximum-lus setting.

Recommended Action    No action is required.

Error Message   
%TN3270S-1-MEMORY_SHORTAGE : Insufficient memory on board; failed to allocate [dec] bytes

Explanation    Memory could not be allocated for an important operation.

Recommended Action    Upgrade your board for additional memory. If you believe sufficient memory is on the board, it is possible that there is a memory leak. Report details of your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem to your technical support representative.

Error Message   
%TN3270S-1-NegRsp_NO_CORRELATOR : TN3270E negative response correlation: [chars].[dec], client IP addr [chars], nextSqn=[dec], rspSqn=[dec], 600*ONESEC

Explanation    A TN3270E client sent a negative response to a TN3270 request sent previously by the server. The negative response does not have a sequence number that can be correlated by the server.

Recommended Action    Determine the DLOGMOD used for the session. Review the outbound pacing bits used for this session and ensure that the pacing value is no bigger than 4. If problems persist, contact the client software vendor and lodge a problem report.

Error Message   
%TN3270S-1-NO_BIND_REQ_RCVD : No BIND REQ received on LU [chars].[dec], 120*ONESEC

Explanation    Either a BIND REQUEST or SSCP-LU data was expected (but not received) from the host within 30 seconds from the start of SSCP-LU session for this TN3270 session. If the condition persists for another 2 minutes, the LU is declared bad. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.

Recommended Action    Examine the system services control point (SSCP) host VTAM console for status of the specified PU and LU. Review the VTAM console log output for relevant events (such as deactivation of the PU or LU). If, after VTAM console review, the cause is still unknown, report this error to your technical support representative. A temporary workaround is simply to recycle the affected LU at the VTAM console. This will put the LU back into normal circulation.

Error Message   
%TN3270S-1-NO_DYN_ACTLU_REQ_RCVD : No ACTLU REQ received on LU [chars].[dec], 120*ONESEC

Explanation    The host has not sent an ACTLU REQ within 30 seconds of sending a Reply-PSID RSP. If this condition persists for another 2 minutes, the current TN3270 session connected to the LU is disconnected. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.

Recommended Action    Examine the system services control point (SSCP) host VTAM console for status of the specified PU and LU. Review the VTAM console log output for relevant events (such as deactivation of the PU or LU). If, after VTAM console review, the cause is still unknown, report this error to your technical support representative. A temporary workaround is simply to recycle the affected LU at the VTAM console. This will put the LU back into normal circulation.

Error Message   
%TN3270S-1-NO_EVENT_BUFS : No IPC sysmgt event buffers for at least one minute , 600*ONESEC

Explanation    The TN3270 server has events that will result in SNMP traps and/or SNA Alerts, but has not been able to allocate IPC buffer resources to report the events to router system code. The TN3270 server will continue to try to report these events, but lack of buffers may continue until a CIP microcode reload is performed.

Recommended Action    Report this problem to your technical representative. Include output from the following commands:

As a workaround, reload the CIP microcode.

Error Message   
%TN3270S-1-NO_LU_MEMORY : No memory on the CIP was available for completing a requested TN3270 LU session

Explanation    Insufficient memory is available to the TN3270 server to complete one or more requests by TN3270/E clients for LU sessions. The sessions have been disconnected.

Recommended Action    Review the memory required to run the TN3270 server application in light of current client load. Install additional memory, if necessary.

Error Message   
%TN3270S-4-NO_LU_SESSIONS : No LU sessions left for PUs at IP addr [chars], port [dec], 600*ONESEC

Explanation    The TN3270 server cannot complete one or more connection requests from a TN3270/E client because no more available LUs are left in the generic pool associated with the specified IP listening-point address.

Recommended Action    Review the LU requirements for the application endpoints. Configure additional PUs listening at the specified IP address and port number.

Error Message   
%TN3270S-1-NO_NTFY_AV_RSP_RCVD : No NOTIFY(available) RSP received on LU [chars].[dec], 120*ONESEC

Explanation    No response to a power-on (AVAILABLE) NOTIFY request was received by the TN3270 server within 30 seconds of sending it to the host. If this condition persists for another 2 minutes, the current TN3270 session connected to the LU is disconnected. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.

Recommended Action    Examine the system services control point (SSCP) host VTAM console for status of the specified PU and LU. Review the VTAM console log output for relevant events (such as deactivation of the PU or LU). If, after VTAM console review, the cause is still unknown, report this error to your technical support representative. A temporary workaround is simply to recycle the affected LU at the VTAM console. This will put the LU back into normal circulation.

Error Message   
%TN3270S-1-NO_NTFY_UA_RSP_RCVD : No NOTIFY(UA) RSP received on LU [chars].[dec], 120*ONESEC

Explanation    No response to a power-off (UNAVAILABLE) NOTIFY request was received by the TN3270 server within 30 seconds of sending it to the host. If this condition persists for another 2 minutes, the current TN3270 session connected to the LU is disconnected. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.

Recommended Action    Examine the system services control point (SSCP) host VTAM console for status of the specified PU and LU. Review the VTAM console log output for relevant events (such as deactivation of the PU or LU). If, after VTAM console review, the cause is still unknown, report this error to your technical support representative. A temporary workaround is simply to recycle the affected LU at the VTAM console. This will put the LU back into normal circulation.

Error Message   
%TN3270S-1-NO_PSID_RSP_RCVD : No NMVT Reply PSID received on LU [chars].[dec], 120*ONESEC

Explanation    No response to a Reply PSID was received by the TN3270 server within 30 seconds of sending it to the host. This fault can only occur on dynamic LUs that have been misconfigured or de-activated at the host. If this condition persists for another 2 minutes, the current TN3270 session connected to the LU is disconnected. Bad dynamic LUs are placed in a special area where no attempt to reuse them is made until all other generic-pool LUs of the IP listening point have been exhausted.

Recommended Action    Check the status of the LU via VTAM, and vary the LU active if appropriate. This action must happen within 2 minutes of the time that this message appears; otherwise, the LU is placed in "bad" LU area and will not be reused unless all good LUs are in use. Examine the host VTAM log for trouble. In particular, look for messages indicating a badly configured LUGROUP resource definition or file. Fix the configuration and recycle the affected major nodes.

Error Message   
%TN3270S-1-NO_SDT_REQ_RCVD : No SDT REQ received on LU [chars].[dec], 120*ONESEC

Explanation    No SDT (Start Data Transfer) REQ was received by the TN3270 server from the PLU host for the specified LU. If the condition persists for another 2 minutes, the LU is declared bad. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.

Recommended Action    Examine the system services control point (SSCP) host VTAM console for status of the specified PU and LU. Review the VTAM console log output for relevant events (such as deactivation of the PU or LU). If, after VTAM console review, the cause is still unknown, report this error to your technical support representative. A temporary workaround is simply to recycle the affected LU at the VTAM console. This will put the LU back into normal circulation.

Error Message   
%TN3270S-1-NO_SDT_TMARK_RCVD : No SDT TIMING-MARK received on LU [chars].[dec], 120*ONESEC

Explanation    No SDT (Start Data Transfer) TIMING-MARK response was received by TN3270 server from the TN3270 client software for the specified TN3270 session. If the condition persists for another 2 minutes, the LU is declared bad. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.

Recommended Action    Some TN3270 clients may not fully handle the TN3270 RFCs. Enable the client-side trace to figure out on what the client is failing. Replace the failing client software with software from the list of TN3270 software types that are known to work with the TN3270 server (see your technical representative for this). If the problem persists, report this error to your technical support representative.

Error Message   
%TN3270S-1-NO_UNBIND_RSP_RCVD : No UNBIND RSP received on LU [chars].[dec], 120*ONESEC

Explanation    No response to an UNBIND request was received by the TN3270 server within 30 seconds of sending the request to the host. If this condition persists for another 2 minutes, the current TN3270 session connected to the LU is disconnected. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening-point are in use.

Recommended Action    Examine the system services control point (SSCP) host VTAM console for status of the specified PU and LU. Review the VTAM console log output for relevant events (such as deactivation of the PU or LU). If, after VTAM console review, the cause is still unknown, report this error to your technical support representative. A temporary workaround is simply to recycle the affected LU at the VTAM console. This will put the LU back into normal circulation.

Error Message   
%TN3270S-1-NO_UNBIND_TMARK_RCVD : No UNBIND-time TIMING-MARK received from client for LU [chars].[dec], 120*ONESEC

Explanation    No UNBIND TIMING-MARK response was received by TN3270 server from the TN3270 client software for the specified TN3270 session. If the condition persists for another 2 minutes, the LU is declared bad. Bad dynamic LUs will not be reused until all good dynamic LUs associated with the IP listening point are in use.

Recommended Action    Some TN3270 clients may not fully handle the TN3270 RFCs. Enable the client-side trace to figure out on what the client is failing. Replace the failing client software with software from the list of TN3270 software types that are known to work with the TN3270 server (see your technical representative for this). If the problem persists, report this error to your technical support representative.

Error Message   
%TN3270S-1-RP_PU_CONFLICT : RP & CIP hold conflicting PU name([chars]) or index(%ld)

Explanation    The Route Processor (RP) requested an update or delete action on a physical unit (PU) resource reported as stale or incorrect by the CIP TN3270 server.

Recommended Action    Reload the CIP microcode. If the problem recurs, copy the error message exactly as it appears. Run and record the output from the following commands on each CIP in the router before reloading the CIP microcode:

Report this message to your technical support representative.

Error Message   
%TN3270S-4-SESSION_NEGOT_TIME_EXPIRED : A client session from [chars]:[dec] failed to negotiate TN3270/TN3270E., 600*ONESEC

Explanation    A Telnet session that failed to negotiate TN3270/TN3270E within a time period was disconnected.

Recommended Action    Try to locate the TN3270 client that caused the problem. There could be a bug in the client or it could be a transient network problem.

Error Message   
%TN3270S-1-SNA_BAD_SEQUENCE : LU-LU session bad sequence number, lu [chars].[dec] expected snf = [dec], current snf = [dec]

Explanation    An unexpected LU-LU session sequence was received. The LU was presented to the LU named by the LOCADDR and PU. The error will cause a negative response of sense code X2001 to send to the host.

Recommended Action    Examine the system services control point (SSCP) host VTAM console for status of the specified LU. Get a trace output for the specified LU and report this problem to your technical support representative.

Error Message   
%TN3270S-1-SNA_BAD_WSF : LU-LU session [chars].[dec] WSF data is illegal

Explanation    A WSF 3270DS Write with wrong data length was received.

Recommended Action    Examine what application in the host sends this WSF, and report this problem to your technical support representative.

Error Message   
%TN3270S-1-SNA_NO_PU_RESPONSE : PU [chars] locaddr [dec] does not get a response in 30 seconds

Explanation    A PU sent a request to the host but did not get a response in 30 seconds.

Recommended Action    Check to see if the PU is still in ACT/BUSY state. Examine to see if the VTAM can talk to the PU. Check the LLC2 connection.

Error Message   
%TN3270S-4-SO_SNDBUF_FAILED : TNSetBindParam:SO_SNDBUF setsockopt for session failed sendSize [dec] err [dec]

Explanation    An internal error occurred while setting the transmit window size on TCP session, so the session is using a default window size.

Recommended Action    Report this message to your technical support representative. Also send your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem.

Error Message   
%TN3270S-1-START_FAIL : Failed to start TN3270-server

Explanation    The TN3270 server failed to start correctly, and is now not running. The immediately preceding error messages point to the cause of the failure.

Recommended Action    Review the previous error messages to discover what caused the start failure, and take action based on those messages.

Error Message   
%TN3270S-6-START_OK : Starting TN3270-server

Explanation    This is an informational message announcing the bringing up of the TN3270 server subsystem.

Recommended Action    No action is required.

Error Message   
%TN3270S-1-STARTUP_RACE : InitTimerService Failed;Previous timer service still up

Explanation    The shutdown of TN3270 server was not finished when a new reincarnation was attempted.

Recommended Action    If this problem is caused by a quick restart of the TN3270 server, try to restart the TN3270 server. Report this message to your technical support representative. Also send your configuration, output from the show controllers cxbus command, and any action you must do to reproduce this problem.

Error Message   
%TN3270S-6-STOPPING : Stopping Tn3270-server

Explanation    This is an informational message announcing the shutdown of the TN3270 server subsystem.

Recommended Action    No action is required.

Error Message   
%TN3270S-2-TELNETINITFAIL : Initialization of Tn3270 server Failed

Explanation    Initialization of Telnet component of TN3270 server failed.

Recommended Action    This is most probably because of inadequate memory on the CIP card. Check the memory, and report this message to your technical support representative.

Error Message   
%TN3270S-4-TN3270_CONFIG_INCOMPATIBLE : IOS sub-codepoint [dec] with length [dec] not understood, 600*ONESEC

Explanation    The TN3270 server received a configuration command from the Cisco IOS newer than CIP expects. Some functionality may not be implemented.

Recommended Action    Check that the Cisco IOS version is compatible with the CIP version.

Error Message   
%TN3270S-4-TOO_MANY_HOST_WRITES : Client on PU [dec]:locaddr [dec] ip [chars]:[dec] is being disconnected;Check outbound LU pacing

Explanation    This could either be a transient network problem or an internal error in server.

Recommended Action    Ensure that LU outbound pacing is configured. If that is correct, try to locate the TN3270 client that caused the problem. There could be a bug in the client. Also, try to get a Telnet trace of the session by reproducing the problem. Report this error to your technical support representative.

Error Message   
%TN3270S-7-UNKNOWN_SNA_MSG : Unknown message for PU [chars], data: [chars]

Explanation    A SNA message from the host is invalid.

Recommended Action    If it only happens once, this could be a glitch in the line. Record the message for later reference. If this error recurs, check if the host is configured correctly.

CIP-UTIL Error Message

CIP error message related to Channel Adapter utilities

Error Message   
%UTIL-3-LINKLIST : [chars]([hex])

Explanation    An internal software error occurred.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.