Technical Specifications

Technical Specifications

Table A-1 and Table A-2 provide the technical specifications and regulatory agency approvals for the FastHub 112T and FastHub 124T.


Table  A-1:
Technical Specifications
Environmental Operating Ranges

Operating temperature

23 to 113×F (-5 to 45×C)

Storage temperature

-13 to 158×F (-25 to 70×C)

Operating humidity

10 to 85% (noncondensing)

Operating altitude

Up to 9842 ft (3000 m)
Power Requirements

AC input voltage

90 to 127/200 to 250 VAC (autoranging) 50 to 60 Hz

DC input voltage

+5V
+12V

@1A

Power consumption

FastHub 112T--25W
FastHub 124T--35W
Physical Dimensions

Weight

11 lb (5 kg)

Dimensions (H x W x D)

1.73 x 17.5 x 8.25 in. (4.4 x 44.5 x 21 cm)

Table  A-2:
Agency Approvals

Approvals:

Safety EMI
AS/NZS 3260, TS001 FCC Part 15 Class A
UL 1950/CSA 22.2 No. 950 EN 55022B Class B (CISPR 22 Class B)
IEC 950/EN 60950 VCCI Class II
NOM 019 AS/NRZ 3548 Class B
CE CE