This chapter contains detailed descriptions of the IPX/IGX/BPX Software Release 8.4 super user commands. The IPX/IGX/BPX super user command descriptions appear in alphabetical order. Access to these commands requires user-privilege level 0 (zero).
![]() | Caution Use of these commands should be restricted to StrataCom personnel and other qualified users, such as System Administrators. Do not distribute this information to casual users because improper use of some super user commands may lead to system malfunction or complete failure. |
Table 1-1 lists the IPX/IGX/BPX level 0 (super user) commands in alphabetical order. The table also lists the nodes on which each command is available and whether you can include the command in a job. To access these commands, type in SuperUser at the login prompt. Enter the super user password and the password prompt. To exit a command at any point, press the Delete key.
The screen examples in this chapter are based on a network containing an IPX, IGX, or BPX or any combination of these nodes. For detailed descriptions of commands requiring a user-privilege level in the range 1-6, refer to the Command Reference.
| Command | Description | Job | IPX | IGX | BPX |
|---|---|---|---|---|---|
| burnfwrev | Burn Firmware Revision | Yes | X | X | X |
| clrcderrs | Clear Detailed Card Errors Log | Yes | X | X | X |
| clrcnf | Clear Configuration Memory | No | X | X | X |
| clrfpevt | Clear FastPAD Event Reporting | No | X | X | |
| cnfcdpparm | Configure CDP Card Parameters | No | X | X | |
| cnfcftst | Configure Communications Fail Test Pattern | No | X | X | X |
| cnfchstats | Configure Channel Statistics Collection | Yes | X | X | X |
| cnfchts | Configure Channel Timestamp | Yes | X | X | X |
| cnfclnparm | Configure Circuit Line Parameters | No | X | X | |
| cnfclnsigparm | Configure Circuit Line Signalling Parameters | No | X | X | |
| cnfclnstats | Configure Circuit Line Statistics Collection | Yes | X | X | |
| cnfcmparm | Configure Connection Management Parameters | Yes | X | X | X |
| cnfdiagparm | Configure Diagnostic Test Parameters | No | X | X | X |
| cnfdlparm | Configure Download Parameters | No | X | X | X |
| cnfecparm | Configure Echo Canceller Parameters | Yes | X | X | |
| cnffpcom | Configure FastPAD Communication Parameter | Yes | X | X | |
| cnffpcon | Configure FastPAD Connection Parameters | Yes | X | X | |
| cnffpddelay | Configure FastPad Sc/Mc Parameters | No | X | X | |
| cnffpdpvc | Configure FastPad bc/bc pvc Parameters | No | X | X | |
| cnffpmap | Configure FastPAD Map Table | Yes | X | X | |
| cnffpport | Configure FastPAD Port Parameters | No | X | X | |
| cnffpsys | Configure FastPAD System Parameters | No | X | X | |
| cnffstparm | Configure Frame Relay ForeSight Node Parameters | No | X | X | X |
| cnflnparm | Configure ATM Line Parameters | No | X | ||
| cnflnsigparm | Configure Line Signalling Parameters | No | X | X | |
| cnflnstats | Configure Line Statistics Collection | Yes | X | X | X |
| cnfmxbutil | Configure MUXBUS Utilization | No | X | X | |
| cnfnodeparm | Configure Node Parameters | No | X | X | X |
| cnfnwip | Configure Network IP Address | No | X | X | X |
| cnfportstats | Configure FR Port Statistics Collection | Yes | X | X | |
| cnfqstats | Configure Queue Statistics Collection | Yes | X | X | X |
| cnfrobparm | Configure Robust Alarms Parameters | No | X | X | X |
| cnfslotstats | Configure Slot Statistics Collection | Yes | X | ||
| cnftcpparm | Configure TCP Parameters | Yes | X | X | X |
| cnftlparm | Configure Trunk-based Loading Parameters | No | X | X | X |
| cnftrkparm | Configure Trunk Parameters | No | X | X | X |
| cnftrkstats | Configure Trunk Statistics Collection | Yes | X | X | X |
| cnftstparm | Configure Card Self Test Parameters | Yes | X | X | X |
| cnfuiparm | Configure User Interface Parameters | No | X | X | X |
| cnfvchparm | Configure Voice Channel Parameters | Yes | X | X | |
| cpyfpmap | Copy FastPAD Map Table | Yes | X | X | |
| dchst | Display CDP Channel Status | No | X | X | |
| diagbus | Diagnose Failed Bus | No | X | X | |
| drtop | Display Route Op Table | No | X | X | X |
| dspasich | Display ASI Channel Routing Entry | No | X | ||
| dspbuses | Display Bus Status | No | X | X | X |
| dspcardstats | Display Card Stats | No | X | X | X |
| dspcderrs | Display Card Errors | No | X | X | X |
| dspcftst | Display Communications Fail Test Pattern | No | X | X | X |
| dspchan | Display Channel Configuration | No | X | X | |
| dspchstatcnf | Display Statistics Enabled for a Channel | No | X | X | |
| dspchstathist | Display Statistics Data for a Channel | No | X | X | |
| dspclnstatcnf | Display Statistics Enabled for a Circuit Line | No | X | X | |
| dspclnstathist | Display Statistics History for a Circuit Line | No | X | X | X |
| dspcnf | Display Config. Save/Restore Status | No | X | X | X |
| dspdnld | Display Download | No | X | X | X |
| dspdutl | Display Data Channel Utilization | No | X | X | |
| dspecparm | Display Echo Canceller Parameters | No | X | X | |
| dspfpdsc | Display FastPAD Card Descriptor Parameters | No | X | X | |
| dspfwrev | Display Firmware Revision | No | X | X | X |
| dsplnstatcnf | Display Statistics Enabled for a Line | No | X | X | X |
| dsplnstathist | Display Statistics Data for a Line | No | X | X | X |
| dspplnmcons | Display Packet Line Connection Counts | No | X | X | |
| dspportstatcnf | Display Statistics Enabled for a FR Port | No | X | X | |
| dspportstathist | Display Statistics Hist for a FR Port | No | X | X | |
| dspqstats | Display Queue Statistics | Yes | X | X | X |
| dsprevs | Display Revisions | No | X | X | X |
| dsprobst | Display Robust Statistics | No | X | X | X |
| dsprrst | Display Reroute Statistics | No | X | X | X |
| dspsig | Display Signalling | No | X | X | |
| dspslot | Display Slot | No | X | X | X |
| dspslotstatcnf | Display Statistics Enabled for a Slot | No | X | X | X |
| dspslotstathist | Display Statistics Hist for a Slot | No | X | X | X |
| dspstatmem | Display Statistics Memory Use | No | X | X | X |
| dsptcpparm | Display TCP Parameters | No | X | X | X |
| dsptrkcons | Display Trunk Connection Counts | No | X | X | X |
| dsptrkmcons | Display Trunk Connection Counts by Master Node | No | X | X | X |
| dsptrkstatcnf | Display Statistics Enabled for a Trunk | No | X | X | X |
| dsptrkstathist | Display Statistics History for a Trunk | No | X | X | X |
| dsputl | Display Voice Connection Utilization | No | X | X | |
| forcerev | Force Revision | No | X | X | X |
| getfwrev | Get Firmware Revision | Yes | X | X | X |
| loadcnf | Load Configuration | Yes | X | X | X |
| loadrev | Load Revision | No | X | X | X |
| prtcderrs | Print Card Errors | Yes | X | X | X |
| rrtcon | Reroute Connection | Yes | X | X | X |
| rststats | Reset Statistics Collection TIme | Yes | X | X | X |
| runcnf | Run Configuration | No | X | X | X |
| runrev | Run Revision | No | X | X | X |
| savecnf | Save Configuration | Yes | X | X | |
| setfpevt | Set FastPAD Events | No | X | X | |
| tststats | Test Statistics | No | X | X | X |
The StrataView Plus workstation provides on-line help for all IPX/IGX/BPX commands. On-line help can be accessed through the StrataView Plus FrameViewer icon. On-line help provides an abbreviated version of the information in this document, including the command function, syntax, and attributes. Hypertext links allow you to navigate through the various commands.
The pages that follow contain the description of the super user commands in alphabetical order. Whenever applicable, the command description includes a description of the options and at least one example of a typical screen display for the command.
This manual is valid only for Release 8.4 or later system software. Commands that apply to older cards used with older software or that have been replaced by newer cards are not represented here. Refer to the Rel. 6.2 IPX SuperUser Commands User Guide for commands that operate on the older cards or their newer replacements.
The burnfwrev command burns a new firmware image into a specific card.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
dspfwrev, getfwrev
| <image name> | specifies the name of the firmware image to burn. Image names are generally in all capital letters and are case-sensitive when being entered. |
| <slot number> | specifies the shelf slot where the card to burn is located. Specifying slot 0 will burn all cards of the appropriate type at the local node. |
This command is used to burn (load) a firmware image into the memory of a specific IPX/IGX/BPX card. Before using this command, the firmware image must have already been loaded into controller card's memory by the getfwrev command. A few seconds after issuing this command, the system displays a screen similar to Figure 1-1. A few moments later, the burn address column will start to indicate the addresses that are being "burned." When finished, the status will change to "Complete."
After all cards at a node have been updated with this command, issue a getfwrev 0.0 node name command. This command will clear the firmware image from the controller card's buffer area, allowing the buffer to be used for other purposes. Use the dspfwrev command to display the firmware image status on the controller card at any other time after the burn has been completed.
At the super user level (0), this command can only be used to change the revision level of a card's firmware. If the firmware revision results in a new model number for the card, only a user with the StrataCom privilege level will be able to burn the firmware image.
gamma TRM SuperUser Rev: 8.4 Jan. 17 1997 14:28 PDT Firmware Size Status F.D.A 256 K Burning into slot 19 (6 lives) File Address Length CRC Burn Address 0 800000 10 E986E939 1 800800 410 22996DDA 2 801000 2D40 B212147F 3 805E60 480 85CB29EA 4 80A630 70 57A938AE 5 80A6B0 20 4B9E8DDC 6 810000 10000 338E45F6 7 820000 4400 95990113 8 835000 1810 875771B2 9 8368A0 15D0 4C597B97 This Command: burnfwrev Continue?
The clrcderrs command clears the history of card failures (errors) associated with the specified slot.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
dspcderrs, prtcderrs
| <slot number | *> | specifies the slot number to clear. A "*" can be entered to clear all cards. |
This command clears the history of card failures associated with the specified slot. When you enter this command system responds with Slot Number or *. After you enter the command, the system asks you to confirm that it is OK to clear this data.
For example, to clear the data from the FRM card in slot 3, enter the command illustrated in Figure 1-2. This screen also illustrates the card's stored data.
pubsigx1 TN StrataCom IGX 32 8.4 Jan. 5 1997 18:48 GMT FRM in Slot 3 : 172240 Rev ESJ Failures Cleared: Date/Time Not Set ----------------------------------- Records Cleared: Date/Time Not Set Self Test Threshold Counter: 0 Threshold Limit: 300 Total Pass: 495 Total Fail: 0 Total Abort: 2 First Pass: Date/Time Not Set Last Pass: May 29 1996 19:36:48 GMT First Fail: Last Fail: Background Test Threshold Counter: 0 Threshold Limit: 300 Total Pass: 29849 Total Fail: 0 Total Abort: 0 First Pass: Date/Time Not Set Last Pass: Jan. 5 1997 18:46:34 GMT First Fail: Last Fail: Hardware Error Total Events: 0 Threshold Counter: 0 First Event: Last Event: This Command: clrcderrs 3 OK to clear (y/n)?
After replying 'y' (yes) to the confirmation prompt, the screen appears as in Figure 1-3.
pubsigx1 TN StrataCom IGX 32 8.4 Jan. 5 1997 18:55 GMT FRM in Slot 3 : 172240 Rev ESJ Failures Cleared: Date/Time Not Set ----------------------------------- Records Cleared: Jan. 5 1997 18:55:02 GMT Self Test Threshold Counter: 0 Threshold Limit: 300 Total Pass: 0 Total Fail: 0 Total Abort: 0 First Pass: Last Pass: First Fail: Last Fail: Background Test Threshold Counter: 0 Threshold Limit: 300 Total Pass: 0 Total Fail: 0 Total Abort: 0 First Pass: Last Pass: First Fail: Last Fail: Hardware Error Total Events: 0 Threshold Counter: 0 First Event: Last Event: Last Command: clrcderrs 3 Next Command:
The clrcnf command clears the configuration memory at the current node and resets the node.
Jobs: No Log: No Lock: Yes Node Type: IPX, IGX, BPX
loadcnf, runcnf, savecnf
The clcnf command erases most network configuration data. This data pertains to connections, trunks, circuit lines, and so on, for the local node. You may need to use the clcnf command when you upgrade the network with a new software release or when you move a node. Before the command executes, a warning and a confirmation prompt. Figure 1-4 illustrates a typical screen.
This command should be used only on a node that has not yet been placed in service or when the network configuration has been previously saved so it can be quickly reloaded. The configuration can be saved in one of several ways:
![]() | Caution Use clrcnf with extreme caution. Typically, you should use clrcnf only if the WANBU TAC has instructed you to do so. This command can make the node unreachable to the network. |
*** Warning: *** This command clears the configuration memory and resets the Node. This Command: clrcnf Are you sure (y/n)?
The clrfpevt command disables the reporting of FastPAD events.
Jobs: No Log: Yes Lock: No Node Type: IPX, IGX
setfpevt, dsplog
The reason for executing clrfpevt is to prevent the large number of logged events that accumulate when certain user-controlled disruptions occur. Without suspension of event-logging, the number of events caused by the disruption can cause the FastPAD to become unreachable. Remember to resume event logging by using the setfpevt command. Examples of these events are:
clfpevt 9.3
The example command halts event logging for the FastPAD connected to port 9.3.
sw152 TN StrataCom IGX 16 8.4 Nov. 26 1997 15:14 GMT
Most recent log entries (most recent at top)
Class Description Date Time
Info FP fp93 event: 9.3.B grp:0-0 code:12 11/26/97 15:13:28
Info FP fp93 event: 9.3.B grp:0-0 code:1 11/26/97 15:13:28
Info User StrataCom logged in (Local) 11/26/97 14:28:40
Info User StrataCom logged in (Local) 11/26/97 12:56:49
Info Invalid Login Attempt via LAN Port (Local) 11/26/97 12:56:46
Info User StrataCom logged in (Local) 11/26/97 11:31:51
Info AD 9.2.3 dallas COM OK (Kickoff) 11/26/97 11:23:17
Info AD 9.2.3 dallas Unreachable 11/26/97 10:59:32
Info AD 9.2.3 dallas COM OK (Kickoff) 11/26/97 10:56:54
Info FP fp93 event: 9.3.B grp:0-0 code:12 11/25/97 18:16:45
Info FP fp93 event: 9.3.B grp:0-0 code:1 11/25/97 18:16:45
Last Command: dsplog
Next Command:
The cnfcdpparm command configures parameters for the CVM or CDP.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
cnfchts, dchst, cnfecparm
| <parameter number> | Specifies the number of the parameter to change. (See Table 1-2). |
| <new value> | Specifies the new value for the parameter. |
The cnfcdpparm command lets you configure CDP or CVM parameters for Voice Activity Detection (VAD), Modem Detection (MDM), debug parameters, and In/Out of Frame (I Frm and
O Frm) Thresholds for DS0A-type T1 applications. See the cnfcln description for information on assigning % Fast Modem on a per-channel basis. Table 1-2 lists the cnfcdpparm parameters. All CDPs or CVMs in the node are dynamically reconfigured according to the new parameters. Debug Parameters do not get sent to the cards. When you enter the command, the system prompts for a parameter number.
![]() | Caution You should consult Cisco TAC before changing any of these parameters. |
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 15:21 PST 1 VAD High Pwr Thrsh [3160] (H) 15 MDM Pkt Header [ 6] (D) 2 VAD Mid Pwr Thrsh [ 40] (H) 16 Null Timing Pkt Header [ 4] (D) 3 VAD Low Pwr Thrsh [ 40] (H) 17 Debug Parm A [ 0] (H) 4 VAD Stationary Coef. [ 30] (H) 18 Debug Parm B [ 0] (H) 5 VAD ZCR High Frq Thrsh [ 50] (H) 19 I Frm 2.4 Thrsh (msecs) [ 500] (D) 6 VAD ZCR Low Frq Thrsh [ 15] (H) 20 O Frm 2.4 Thrsh (msecs) [ 500] (D) 7 VAD Hangover Time [ 42] (H) 21 I Frm 4.8 Thrsh (msecs) [ 500] (D) 8 MDM Low Pwr Thrsh [3160] (H) 22 0 Frm 4.8 Thrsh (msecs) [ 500] (D) 9 MDM Stationary Coef. [ 14] (H) 23 I Frm 9.6 Thrsh (msecs) [ 500] (D) 10 MDM ZCR High Frq Thrsh [ 5A] (H) 24 O Frm 9.6 Thrsh (msecs) [ 500] (D) 11 MDM ZCR Low Frq Thrsh [ 56] (H) 12 MDM Detect Failure Cnt [ 4] (H) 13 MDM Detect Window Min. [ 39] (H) 14 MDM Detect Silence Max. [ 20] (H) This Command: cnfcdpparm Which parameter do you wish to change:
| No. | Parameter | Description | Default * |
|---|---|---|---|
| 1 | VAD High Power Threshold | Power level for Voice Activity Detect high-range threshold. | 3160 (H) |
| 2 | VAD Mid Power Threshold | Power level for Voice Activity Detect mid-range threshold. | 40 (H) |
| 3 | VAD Low Power Threshold | Power level for Voice Activity Detect low-range threshold. | 40 (H) |
| 4 | VAD Stationary Coefficient | Indicates how rapidly the power level is changing to not be detected as voice. | 30 (H) |
| 5 | VAD ZCR (zero crossing) High Freq Threshold | High frequency zero-crossing threshold for Voice Activity Detect. | 50 (H) |
| 6 | VAD ZCR (zero crossing) Low Freq Threshold | Low frequency zero-crossing threshold for Voice Activity Detect. | 15 (H) |
| 7 | VAD Hangover Time | Silent interval after speech during which cells/packets are still sent. | 42 (H) |
| 8 | MDM Low Power Threshold | Power level for Modem Detect high-range threshold. | 3160 (H) |
| 9 | MDM Stationary Coefficient | Indicates how rapidly the power level is changing to not be detected as modem. | 14 (H) |
| 10 | MDM ZCR High Freq Threshold | Defines upper frequency value for 2100 Hz. tone used in V.25 modem detection. | 5A (H) |
| 11 | MDM ZCR Low Freq Threshold | Defines lower frequency value for 2100 Hz. tone used in V.25 modem detection. | 56 (H) |
| 12 | MDM Detect Failure Count | Defines no. of failures above which fast modem is not declared. | 4 (H) |
| 13 | MDM Detect Window Min. | No. of 5.25 ms. windows used in the modem tests. | 39 (H) |
| 14 | MDM Detect Silence Max. | Amount of time a channel stays in a modem detected state. Value X 84 ms. Default = 1008 ms. | C (H) |
| 15 | MDM Pkt Header | Changes packet type from voice to non-timestamped for modems. | 6 (D) |
| 16 | Null Timing Pkt Header | Gives first few voice packets higher priority to decrease delay for talk spurts. | 4 (D) |
| 17 | Debug Parameter A | Engineering debug tools. | 0 (H) |
| 18 | Debug Parameter B | Engineering debug tools. | 0 (H) |
| 19 | I Frm 2.4 Threshold(msecs) | Determines threshold for inframe for DS0 2.4 Kbps overhead data channel. | 500 (D) |
| 20 | O Frm 2.4 Threshold (msecs) | Determines threshold for out of frame for DS0 2.4 Kbps overhead data channel. | 500 (D) |
| 21 | I Frm 4.8 Threshold (msecs) | Same as 19 for DS0 4.8 Kbps channel. | 500 (D) |
| 22 | 0 Frm 4.8 Threshold(msecs) | Same as 20 for DS0 4.8 Kbps channel. | 500 (D) |
| 23 | I Frm 9.6 Threshold(msecs) | Same as 19 for DS0 9.6 Kbps channel. | 500 (D) |
| 24 | O Frm 9.6 Threshold (msecs) | Same as 20 for DS0 9.6 Kbps channel. | 500 (D) |
| |||
The cnfcftst command changes the configuration of the test pattern used for communication failure testing.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
dspcftst
The communication fail test pattern is used to periodically test for failure of nodes to communicate with each other. This test pattern is also used to recover from communication fail conditions. A communication fail is defined as a loss of controller communication over one or more trunks to a particular node. A communication fail differs from a communication break condition in that the node may be reachable over other paths. The communication fail test is used to test the failed trunk for proper controller traffic.
This command allows the user to configure the communication fail test pattern byte-by-byte. It defaults to a pattern of 4 bytes of 1s followed by 4 bytes of 0s. Varying the length of the test pattern makes the communications test more or less rigorous. Changing the characters determines the pattern sensitivity for strings of less than 14 bytes.
The dspcftst command displays the current communication test pattern. The parameters used for declaring and clearing communication fails are set by the cnfnodeparm command. Figure 1-5 illustrates a typical screen.
pubsigx1 TN StrataCom IGX 32 8.4 Feb 24 1997 21:17 GMT
Comm Fail Test Pattern
==> Byte 0: FF Byte 12: 00 Byte 24: FF Byte 36: 00 Byte 48: FF
Byte 1: FF Byte 13: 00 Byte 25: FF Byte 37: 00 Byte 49: FF
Byte 2: FF Byte 14: 00 Byte 26: FF Byte 38: 00 Byte 50: FF
Byte 3: FF Byte 15: 00 Byte 27: FF Byte 39: 00 Byte 51: FF
Byte 4: 00 Byte 16: FF Byte 28: 00 Byte 40: FF Byte 52: 00
Byte 5: 00 Byte 17: FF Byte 29: 00 Byte 41: FF Byte 53: 00
Byte 6: 00 Byte 18: FF Byte 30: 00 Byte 42: FF Byte 54: 00
Byte 7: 00 Byte 19: FF Byte 31: 00 Byte 43: FF Byte 55: 00
Byte 8: FF Byte 20: 00 Byte 32: FF Byte 44: 00 Byte 56: FF
Byte 9: FF Byte 21: 00 Byte 33: FF Byte 45: 00 Byte 57: FF
Byte 10: FF Byte 22: 00 Byte 34: FF Byte 46: 00 Byte 58: FF
Byte 11: FF Byte 23: 00 Byte 35: FF Byte 47: 00 Byte 59: FF
This Command: cnfcftst
Enter Byte 0:
cnfchstats (Configure Channel Statistics Collection)
The cnfchstats command enables statistics collection for various channel parameters.
Jobs: Yes Log: Yes Lock: Yes Node Type: BPX, IGX, IPX
dspchstatcnf
| <channel> | specifies the channel (connection) to configure. |
| <stat> | specifies the type of statistic to enable/disable. (See Table 1-3). |
| <interval> | specifies the time interval of each sample (1-255 minutes). |
| <e|d> | enables/disables a statistic. 'E' to enable; 'D' to disable a statistic. |
| [samples] | specifies the number of sample to collect (1-255). |
| [size] | specifies the number of bytes per data sample (1, 2 or 4). |
| [peaks] | enables/disables the collection of one minute peaks. 'Y' to enable: 'N' to disable. |
| [nodename] | specifies the name of the node to which the StrataView terminal is connected. |
This command enables statistics collecting for channel parameters. It is a debug tool and not necessary for everyday use.
Table 1-3 lists the statistics by type. Not all statistic types are available for all connections. Only valid statistics are displayed for the user to select from; the others appear in gray. If you are unsure of the size parameter to specify, select four bytes per sample.
The dspchstatcnf command displays the channel statistics configuration. Statistics are collected by and displayed on the StrataView Plus workstation. StrataView Plus allows statistics collection to be customized. A StrataView Plus-enabled channel statistic may be disabled by specifying the optional node name of the workstation as the last parameter on the command line.
| Statistic Type | Statistic |
|---|---|
| 1 | Frames Received |
| 2 | Receive Frames Discarded |
| 3 | Frames Transmitted |
| 4 | Transmit Frames Discarded |
| 5 | Packets Received |
| 6 | Receive Packets Discarded |
| 7 | Packets Transmitted |
| 8 | Projected Packets Transmitted |
| 9 | Supervisory Packets Transmitted |
| 10 | Bytes Received |
| 11 | Receive Bytes Discarded |
| 12 | Bytes Transmitted |
| 13 | Transmit Bytes Discarded |
| 14 | Seconds V.25 Modem On |
| 15 | Seconds DSI Enabled |
| 16 | Seconds Off-Hook |
| 17 | Seconds In Service |
| 18 | Frames Transmitted with FECN |
| 19 | Frames Transmitted with BECN |
| 20 | Supervisory Packets Received |
| 21 | Minutes Congested |
| 22 | DE Frames Received |
| 23 | DE Frames Transmitted |
| 24 | DE Frames Dropped |
| 25 | DE Bytes Received |
| 26 | Frames Received in Excess of CIR |
| 27 | Bytes Received in Excess of CIR |
| 28 | Frames Transmitted in Excess of CIR |
| 29 | Bytes Transmitted in Excess of CIR |
| 32 | Rx Frames Discarded--Deroute/Down |
| 33 | Rx Bytes Discarded--Deroute/Down |
| 34 | Rx Frames Discarded--VC Queue Overflow |
| 35 | Rx Bytes Discarded--VC Queue Overflow |
| 36 | Tx Frames Discarded--Queue Overflow |
| 37 | Tx Bytes Discarded--Queue Overflow |
| 38 | Tx Frames Discarded--Ingress CRC |
| 39 | Tx Bytes Discarded--Ingress CRC |
| 40 | Tx Frames Discarded--Trunk Discard |
| 41 | Tx Bytes Discarded--Trunk Discard |
| 42 | TX Frames During Ingress LMI Fail |
| 43 | TX Bytes During Ingress LMI Fail |
The cnfchts command configures a pre-aging parameter for data channels. Applicable cards are the SDP, LPD, LDM, and HDM. Applicable traffic is time-stamped data.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX
cnfcdpparm
| <channel(s)> | Specifies the data channel. |
| <pre-age> | Specifies a value in 250-microsecond increments to go in the age field in the header of a time-stamped. |
This command configures the pre-age parameter for data channels. The pre-age parameter specifies the initial age of a time-stamped packet. With a non-zero pre-age, the packet has less time to wait at the destination before it reaches the Max Time Stamped Packet Age and is taken out of the ingress queue. (Data channels with the greater pre-age value are processed sooner.) However, if the pre-age value is too high because of queuing delays in the network, packets could be discarded because they appear too old at the destination.
Enter a value for Pre-Age that is a multiple of 250 microseconds. (If not a multiple of
250 microseconds, the system rounds the value down to the nearest multiple of 250 microseconds.) The default value is 0. Acceptable values are in the range 0 to the Max Time Stamped Packet Age (set by the cnfsysparm command). After you finish entering this command, the screen as in the example. After you change a timestamp, the connection should be rerouted or restarted for the new value to take effect.
pubsipx1 TN StrataCom IPX 16 8.4.00 Jan. 14 1997 03:50 GMT
Maximum EIA % DFM Pattern DFM PreAge
Channels Update Rate Util Length Status (usec)
3.1 2 100 8 Enabled 1000
3.2-4 2 100 8 Enabled 0
Last Command: cnfchts 3.1 1000
Next Command:
The cnfclnparm command configures the alarm integration time for circuit lines originating on a CDP or CVM and for T1/E1 frame relay circuits originating on an FRP, FRM, or UFM.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
cnfclnsigparm, dchst
| <line> | specifies the circuit line to configure. |
This command configures the circuit line alarm integration times for RED and YELLOW circuit line alarms. These integration times are specified in milliseconds and should be set to correspond to the local carrier's alarm integration times. Carrier integration times are typically 800 to 1500 ms. for RED Alarm and 1500 to 3000 ms. for YELLOW Alarm. The allowable range for these parameters are 60 to 3932100 ms. When you enter this command system responds with the screen in Figure 1-6.
D1.gamma TRM SuperUser Rev: 8.4 Jan. 14 1997 14:27 PDT CLN 11 Parameters 1 Red Alarm - In/Out [ 1000 / 2000] (Dec) 2 Yel Alarm - In/Out [ 1000 / 2000] (Dec) This Command: cnfclnparm 11 Which parameter do you wish to change:
cnfclnsigparm (Configure Circuit Line Signaling Parameters)
The cnfclnsigparm command configures signalling parameters for a CVM or CDP.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
cnfclnparm, dspsig
| <parameter number> | specifies the parameter number of the signalling parameter to change. (See Table 1-4.) |
| <parameter value> | specifies the new value to enter. |
The cnfclnsigparm command configures any of the CVM or CDP circuit line signalling parameters associated with the node. See Table 1-4 for the parameters and their values.
When you enter this command system as follows, the system responds with the display as shown in Figure 1-7.
sw83 TN StrataCom IPX 16 8.4. Feb. 1 1997 15:26 PST 1 CDP & CIP Heartbeat [ 2] (sec) 2 CDP & CIP Sig. Polling Rate [ 10] (sec) 3 CDP & CIP Default Inband Sig Delay [ 96] (msec) 4 CDP & CIP Default Inband Playout Delay [ 200] (msec) 5 CDP & CIP Default Pulse Sig Delay [ 96] (msec) 6 CDP & CIP Default Pulse Playout Delay [ 200] (msec) 7 CIP Number of Packet Slices [ 1] 8 CDP & CIP Packet Rate [ 200] (pkt/sec) 9 CDP & CIP Condition CCS Lines? [ NO] 10 CIP Default Inband Min. Wink [ 140] (msec) 11 CIP Default Pulse Min. Wink [ 140] (msec) This Command: cnfclnsigparm Which parameter do you wish to change:
The cnfclnstats command configures parameters for circuit line statistics collection.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX
dspchstats
| <line> | specifies the circuit line to configure. |
| <stat> | specifies the type of statistic to enable/disable. |
| <interval> | specifies the time interval of each sample (1 - 255 minutes). |
| <e|d> | enables/disables a statistic. 'E' to enable; 'D' to disable. |
| [samples] | specifies the number of samples to collect (1 - 255). |
| [size] | specifies the number of bytes per data sample (1, 2 or 4). |
| [peaks] | enables/disables the collection of ten second peaks. 'Y' to enable; 'N' disable. |
The cnfclnstats command configures circuit line statistics. This command lets you customize statistics collection on each circuit line. It primarily applies to debugging and not standard network operation. Table 1-5 lists the statistics by type. Figure 1-8 illustrates the display.
Not all statistic types are available for all lines. Valid statistics appear in full brightness while unavailable types appear in half brightness.
| Statistic Type | Statistic | Line Type |
|---|---|---|
| 1 | Bipolar Violations | E1 and T1 |
| 2 | Frame Slips | E1 and T1 |
| 3 | Out of Frames | E1 and T1 |
| 4 | Loss of Signal | E1 and T1 |
| 5 | Frame Bit Errors | E1 only |
| 6 | CRC Errors | E1 only |
| 7 | Out of Multi-Frames | E1 only |
| 8 | All Ones in Timeslot 16 | E1 only |
Figure 1-8 illustrates the screens displayed after entering cnfclnstats.
D2.ipx5 SV+ SuperUser IPX 16 8.4 Jan. 14 1997 13:28 PDT Line Statistic Types 1) Bipolar Violations 2) Frames Slips 3) Out of Frames 4) Losses of Signal This Command: cnfclnstats 10 Statistic Type:
The cnfcmparm command configures various connection management parameters for the node.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
dsprrst, cnftlparm
| <parameter number> | specifies the number of the parameter to change. See Table 1-6 . |
| <value> | specifies the new parameter value to enter. |
This command configures parameters that affect Adaptive Voice, Rerouting, and Courtesy Up/Down. These parameters are used only at the local node. Table 1-6 lists the parameters, their descriptions, and their default values.
| No. | Parameter | Description | Range | Default |
|---|---|---|---|---|
| 1 | Normalization Interval | The number of minutes between attempts to disable VAD on groups of voice connections. | 1-10 minutes | 2 |
| 2 | Max Number To Normalize | The maximum number of connections per group if the switch attempts to disable VAD on groups of connections. | 1-50 connections | 5 connections |
| 3 | Normalization Logging | Enables or disables the logging of changes in connection's normalization status. | y=yes n=no | No |
| 4 | Settling Interval | After a trunk failure, the number of minutes in which no normalization attempts are made. | 1-10 minutes | 4 minutes |
| 5 | Minimum Open Space | The minimum number of packets per second of open space required to consider a trunk capable of supporting a normalized connection. Increasing this parameter causes all connections to enter the protect mode. | 0-8000 packets per second (pps) | 1000 pps |
| 6 | Normalization Priority | Determines whether the system uses a connection's Class Of Service or its projected load to determine normalization priority. Changing this parameter causes all connections to enter the protect mode. | COS or Load (c/l) | l (Load) |
| 7 | Load Sample Period | The number of minutes of projected load for determining normalization priority if the normalization priority is set to "Load." | 1-10 minutes | 4 minutes |
| 8 | Maximum Routing Bundle | The maximum number of connections that can be routed as a bundle. Larger values result in faster rerouting. Smaller values provide better load balancing. | 1-29 | 24 |
| 9 | Reroute Timer | The number of seconds since the last reroute to wait before attempting another reroute of the same connection. | 0-900 seconds | 300 seconds |
| 10 | Timer Reset on Line Fail | Indicates if the reroute timer should be reset on reroutes where the new route has a line failure. | y=yes n=no | y |
| 11 | Max Down/Up Per Pass | Number of connections downed/upped per pass. | 1-255 | 50 |
| 12 | Down/Up Timer | Number of msec to wait between down/up passes. | 1000-65535 msecs | 30000 msecs |
| 13 | Maximum Route Errors per Cycle | Number of failed attempts that the owner of a connection makes when adding a connection to the calculated route before the owner declares a failed connection. After a connection is failed on an IPX or IGX node, you must use the rrtcon command to route the connection. On a BPX node, further system action may occur before the connection is failed. See index items14 and 15. | 0-65535 failures | 250 |
| 14 | Maximum Time Be- tween Routing Cycles | Applies to BPX nodes. If the connection owner fails to route a connection after the number of attempts specified by Max Route Errors per Cycle, the node can wait a period of time specified by Maximum Time Between Routing Cycles before it again attempts to route the connection. See description of Maximum Routing Error Cycles for the maximum number of routing cycles. | 1-8 minutes | 5 minutes |
| 15 | Maximum Routing Error Cycles | Applies to BPX nodes. Specifies the maximum number of cycles of routing attempts the owner of a connection can make before it declares the connection as failed. (The number of routing attempts in one series of attempts is specified by Max Route Errors per Cycle.) After the connection is failed, you must manually route the command with the rrtcon command. | 0-255 cycles | 20 |
| 16 | Routing pause timer | Specifies a time period for the switch to wait before it routes the next group of connections when the switch is routing groups of connections. (Note that these are not grouped connections.) | 0-65535 msecs | 0 |
| 17 | Max. messages sent per update | The maximum number of failure messages sent out per update. The purpose of this limit is to prevent the switch that is sending the messages from becoming overloaded with message transmission. | 1-223 decimal | 10 |
| 18 | Send SVC urgent msgs | Applies to only IPX nodes for Release 8.4 and works in conjunction with Voice Network Switching (VNS). Enables the node to transmit an urgent message when you remove an SVC. | y=yes n=no | y |
| 19 | Max SVC Retry | Applies to only IPX nodes for Release 8.4 and works in conjunction with Voice Network Switching (VNS). Maximum number of failed routing attempts before the switch declares the SVC a failed connection. | 0-30 decimal | 0 |
| 20 | Wait for TBL updates | The time the switch waits for an update related to trunk-based loading. Each integer you enter is multiplied by 100 msecs. This wait period should be 1 or 2 seconds (10 x 100 msecs or 20 x 100 msecs) longer than the time specified by the Fast Interval parameter of the cnftlparm command. The default for Fast Interval is 50 (50 x 100 msecs=5 seconds), so the default for Wait for TBL updates is 70 (70 x 100 msecs=7 seconds). | 0-65000 decimal | 70 (x100 msecs) |
| 21 | Max derouting bundle | The maximum number of connections in a bundle if the switch deroutes connections in bundles. If you enter a 0 for this parameter, the node can deroute all connections at one time. | 0-7000 decimal | 500 |
| 22 | # of reroute groups used | Specifies the number of connection groups when the switch reroutes connections in groups. Bandwidth is the basis for the connection group assignments: connections with similar bandwidths belong to a group for rerouting purposes. The switch reroutes connections with the highest bandwidth first and continues with groups of decreasing bandwidth ranges.
Any change to this parameter causes a rebuild of the reroute groups, so the interface prompts you for confirmation before the node changes the number. In Release 8.4, this parameter applies to BPX nodes only. | 1-200 groups | 50 |
| 23 | Starting size of RR groups | In Release 8.4, this parameter applies to BPX nodes only. | 0-9600 cell load units (CLUs) | 0 CLUs |
| 24 | Increment between RR grps | Specifies the gap in size between reroute bundles. In Release 8.4, this parameter applies to only BPX nodes. | 1-9600 cell load units (CLUs) | 100 CLUs |
The example shows the two screens required to display all cnfcmparm parameters.
sw66 TN StrataCom BPX 15 8.4 Aug. 28 1997 19:49 GMT
1 Normalization Interval [ 2] (D)
2 Max Number To Normalize [ 5] (D)
3 Normalization Logging [ No]
4 Settling Interval [ 4] (D)
5 Minimum Open Space [ 1000] (D)
6 Normalization Priority [ Load]
7 Load Sample Period [ 4] (D)
8 Maximum Routing Bundle [ 24] (D)
9 Reroute Timer [ 0] (secs)
10 Reset Timer on Line Fail [ Yes]
11 Max Down/Up Per Pass [ 50] (D)
12 Down/Up Timer [30000] (msecs)
13 Max Route Errs per cycle [ 50] (D)
14 Time between Rrt cycles [ 5] (mins)
15 Max. Rrt Err cycles [ 10] (D)
This Command: cnfcmparm
Continue? y
sw66 TN StrataCom BPX 15 8.4 Aug. 28 1997 19:50 GMT
16 Routing pause timer [ 0] (msecs)
17 Max msgs sent per update [ 10] (D)
18 Send SVC urgent msg [ No]
19 Max SVC Retry [ 0] (D)
20 Wait for TBL Updates [ 70] (100 msecs)
21 Max Derouting Bndl (0=all)[ 500] (D)
22 # of reroute groups used [ 50] (D)
23 Starting size of RR grps [ 0] (CLU)
24 Increment between RR grps [ 100] (CLU)
This Command: cnfcmparm
Enter parameter index:
cnfdiagparm (Configure Diagnostic Test Parameter)
The cnfdiagparm command sets various diagnostic test parameters for the nodes.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
cnftstparm
This command sets several parameters that affect the three IPX/IGX/BPX automatic diagnostic tests. Use this command to set test parameters on the internal system clock. Table 1-7 lists the parameters, their descriptions, and their default values.
| No. | Parameter * | Description | Default * |
|---|---|---|---|
| 1 | VDP Test Frequency | Interval between VDP background tests (in seconds). | 50 |
| 2 | LDP tstport delay | Seconds delayed before test data is sent. | 10 |
| 3 | System clock drift (8.192 Mhz) | Range of allowable drift of system clock. | ±480 |
| 4 | UEC-B's PLL railing (8.192 Mhz) | Range of UEC-B's phase lock loop rail. | ± 2720 |
| 5 | NPC's PLL Min. (8.192 Mhz) | Lower limit of controller card's PLL. | - 92000 |
| 6 | NPC's PLL Max. (8.192 Mhz) | Upper limit of controller card's PLL. | + 508000 |
| 7 | Clock Test Window | Number of samples that make up a window. | 10 |
| 8 | Clock Test Max Error in Window | Errors within window before fault isolation. | 4 |
| 9 | Clock Test Isolation Window | Window size during fault isolation. | 10 |
| 10 | Clock Fault Max. Error in Window | Errors allowed during fault isolation. | 3 |
| 11 | Clock Test Frequency | Interval between clock tests. | 200 ms. |
| 12 | Clock Test Switch Delay | Delay clock testing after any clock transfers to allow settling. | 3000 ms. |
| 13 | Card Reset Threshold | 255 | |
| 14 | Card Reset Increment | 0 | |
| |||
When you enter this command, the system responds with the screen illustrated in Figure 1-9.
D2.att7 SV SuperUser IPX 16 8.4 Jan. 13 1997 00:21 GMT
1. Vdp Test Frequency (seconds) [50]
2. LDP tstport delay [10]
3. System clock drift (8.192 MHz) +- [480]
4. UEC-B's PLL railing (8.192 MHz) +- [2720]
5. NPC's PLL minimum (8.192 MHz) - [92000]
6. NPC's PLL maximum (8.192 Mhz) + [508000]
7. Clock Test Window [10]
8. Clock Test Max Error in Window [4]
9. Clock Fault Isolation Window [10]
10. Clock Fault Max Error in Window [3]
11. Clock Test Frequency (msec) [200]
12. Clock Test Switch Delay (msec) [3000]
13. Card Reset Threshold [255]
14. Card Reset Increment [0]
This Command: cnfdiagparm
Enter index of value to be changed:
The cnfdlparm command sets various software and firmware downloader parameters.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
dspdnld
This command sets parameters that affect the SW/FW download protocol. It is primarily a debug command. It is included only for the possibility that some future software or firmware revision may need to be adjusted for optimizing the downloading process.
![]() | Caution Downloader parameters should not be changed except under specific direction from the WANBU TAC. Contact the WANBU TAC through Customer Engineering. |
| No. | Parameter | Description | Range | Default |
| 1 | Rmt Blk Freq | For downloads to a remote node, Rmt Blk Freq is the time between blocks. | 1-9999999 msecs | 100 msecs |
| 2 | Rmt Blk Size | For downloads to a remote node, Rmt Blk Size is the number of bytes in each block. | 1-7C0 hex | 400 hex |
| 3 | Lcl Blk Freq | For downloads to the other processor in the same (local) node, Lcl Blk Freq is the time (in msecs) between blocks. | 1-9999999 msecs | 100 msecs |
| 4 | Lcl Blk Size | For downloads to the other processor in the same (local) node, Lcl Blk Size is the number of bytes in each block. | 1-7C0 hex | 400 hex |
| 5 | Image Req Freq | The time between requests for a description of an image. When a node seeks a new software image from other nodes, it first sends requests for a full description of the image residing on a node to determine if that node has the correct image. The requesting node sends its request one node at a time. Image Req Freq is the time between the last request and the request to another node. (This parameter is not a frequency but rather a time period.) | 1-9999999 msecs | 10000 msecs |
| 6 | Dnld Req Freq | After a node seeking a new software image has found a node with the correct image, it requests a download of the image. If the node with the correct image is not available to send the image, the requesting node waits a period of time before it again requests the image. Dnld Req Freq is the period of time the requesting node waits before it again requests the image. (This parameter is not a frequency but rather a time period.) | 1-9999999 msecs | 10000 msecs |
| 7 | Session Timeout | The time a receiving node waits for a block transfer to resume. If a block transfer stops after downloading begins, the Session Timeout is the time the receiving node waits to resume before it gives up and requests the download again. | 1-9999999 msecs | 30000 msecs |
| 8 | Request Hop Limit | Limit on the number of hops the local node can go to request a download. (The number of hops is the number of trunks that are crossed for one node to communicate with another node.) Request Hop Limit=1 means the request can go to only an immediate neighbor. | 1-9999999 | 1 |
| 9 | Crc Throttle Freq | The number of CRC calculations per second.Crc Throttle Freq lets you reduce the number of calculations so the node does not use processor time for CRC calculations. | 1-9999999 | 5000 |
| 10 | Crc Block Size | Number of bytes that a CRC calculation covers. The default is intentionally the same as Rmt Blk Size and Lcl Blk Size. | 1-7C0 hex bytes | 400 hex |
| 11 | Rev Change Wait | The time to wait before the node actually loads the software for loadrev or runrev execution. | 0-99999 msecs | 0 |
| 12 | CCs Switch Wait | A wait period before the node actually switches control cards during switchcc execution. During normal operation, you should have no reason to increase CCs Switch Wait. | 1-9999999 msecs | 1000 msecs |
| 13 | Lcl Response TO | On a local node, a processor that is downloading to another processor must receive an acknowledgment from the receiving processor for each block that arrived correctly. If the sending processor does not receive an acknowledgment by the time Lcl Response TO has elapsed, the downloading processor sends the block again. | 1-9999999 msecs | 5000 |
| 14 | Rmt Response TO | When one node downloads to another node, the sending node must receive an acknowledgment for each block correctly received. If the sending node receives no acknowledgment by the time Rmt Response TO has elapsed, the sending node sends the block again. | 1-9999999 msecs | 30000 |
| 15 | FW Dnld Block TO | The wait period that a controller card waits for an acknowledgment from a receiving card that it correctly received a block. | 1-9999999 msecs | 50 msecs |
| 16 | FW Dnld Msgs/Block | Number of Cbus messages per CRC block CRC check on the payload of the FW download msg | 1-9999999 msecs | 4 |
| 17 | Flash Write TO | During flash memory programming, Flash Write TO is the time to wait for an acknowledgment that a write cycle finished. | 1-9999999 msecs | 16000 msecs |
| 18 | Flash Erase TO | During a flash memory erasure, Flash Erase TO is the time to wait for an acknowledgment that the erase cycle finished. | 1-9999999 msecs | 100 |
| 19 | Erase Verify TO | Second (or "true") verification of the erasure. The Erase Verify TO parameter is useful only if write/erase performance characteristics of a flash memory device change. | 1-9999999 msecs | 16000 msecs |
| 20 | Standby Flash TO | 1-9999999 msecs | ||
| 21 | Lcl Flash Init TO | 1-9999999 msecs | ||
| 22 | Flsh Write Blk Sz | Number of bytes per write cycle | 1-10000 hex | 10000 hex |
| 23 | Flsh Verify Blk Sz | Second (or "true") verification of the block write. The Flsh Verify Blk Sz parameter is useful only if performance characteristics of a flash memory device change. | 1-10000 hex | 10000 hex |
| 24 | Chips Per Write/Erase | 1, 2, or 4 | 1 |
When you enter this command the system responds with the screen illustrated in Figure 1-10.
pubsbpx1 VT StrataCom BPX 15 8.4 May 24 1997 23:18 GMT 1 Rmt Blk Freq (msec) [ 100] 16 FW Dnld Msgs/Block(dec) [ 4] 2 Rmt Blk Size (hex) [ 400] 17 Flash Write TO(msec) [ 16000] 3 Lcl Blk Freq (msec) [ 100] 18 Flash Erase TO(msec) [ 100] 4 Lcl Blk Size (hex) [ 400] 19 Erase Verify TO(msec) [ 16000] 5 Image Req Freq (msec) [ 10000] 20 Standby Flash TO(sec) [ 300] 6 Dnld Req Freq (msec) [ 10000] 21 Lcl Flash Init TO(msec) [ 1000] 7 Session Timeout (msec) [ 30000] 22 Flsh Write Blk Sz (hex) [ 10000] 8 Request Hop Limit (dec) [ 1] 23 Flsh Verfy Blk Sz (hex) [ 400] 9 Crc Throttle Freq (dec) [ 5000] 24 Chips Per Write/Erase [ 1] 10 Crc Block Size (hex) [ 400] 11 Rev Change Wait(dec) [ 0] 12 CCs Switch Wait(dec) [ 1000] 13 Lcl Response TO(msec) [ 5000] 14 Rmt Response TO(msec) [ 20000] 15 FW Dnld Block TO(msec) [ 50] This Command: cnfdlparm Which parameter do you wish to change:
The cnfecparm command configures the CDP or CVM integrated echo canceller (IEC) parameters for specified voice circuit line.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX
cnfchec, dspecparm
| <line> | specifies the circuit line to configure. |
| <parameter number> | specifies the number of the parameter to change. (See Table 1-9.) |
| <parameter value> | specifies the new value to enter for the parameter. |
The cnfecparm command configures the CVM or CDP integrated echo canceller (IEC). It configures IEC parameters associated with all voice channels for the specified circuit line. Setting these parameters allows you to optimize the IEC performance. Table 1-9 lists the parameters you can modify. The dspecparm command description lists the defaults and provides a sample display. Also, refer to the cnfchec command in the Cisco StrataCom Command Reference for configuring per-channel parameters.
| Index | Parameter | Description | Options |
|---|---|---|---|
| 1 | Echo Return Loss High: | Maximum ERL required for echo canceller to converge on speech (value X 0.1 dB). | 0-99 dB |
| 2 | Echo Return Loss Low: | Minimum ERL required for echo canceller to converge on speech (value X 0.1 dB). | 0-99 dB |
| 3 | Tone Disabler Type | Selection of protocol to enable tone disabler. | G.164, G.165 |
| 4 | Non-Linear Processing | Selects type of post-canceller signal. | Center Clipper, Multiplying |
| 5 | NLP Threshold | Threshold below which non-linear processing is enabled (value X 0.1 dB). | 0-99 dB |
| 6 | Noise Injection | Determines if noise will be injected when NLP is active. | Enable, Disable |
| 7 | Voice Template | Selection of template to use; normal voice levels or high voice levels. | USA--normal UK--high-level |
When you enter this command the system responds with the screen illustrated in Figure 1-11.
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 15:35 PST IEC Line 7 Parameters 1 CDP IEC Echo Return Loss High (.1 dBs) [ 60] (D) 2 CDP IEC Echo Return Loss Low (.1 dBs) [ 30] (D) 3 CDP IEC Tone Disabler Type [ G.164] 4 CDP IEC Non-Linear Processing [Center Clipper] 5 CDP IEC Non-Linear Processing Threshold [ 18] (D) 6 CDP IEC Noise Injection [ Enabled] 7 CDP IEC Voice Template [ USA] This Command: cnfecparm 7 Which parameter do you wish to change:
cnffpcom (Configure FastPAD Communication Parameter)
The cnffpcom command configures the FastPAD communication parameters.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX
None
| <slot.port> | specifies the slot.port of the card to which the FastPAD is connected. |
| <name> | specifies the name of the FastPAD connected to the port. |
| <trans timer> | specifies the transmission timer. |
| <alive timer> | specifies the keep alive timer value. |
| <retry count> | specifies the retry count value. |
This command configures the FastPAD communication parameters. When you enter this command, the system responds as shown in Figure 1-12.
cc7 VT StrataCom IPX 32 8.4 Jan. 30 1997 10:05 PST Last Command: cnffpcom 31.2 2 2 3 Next Command:
The cnffpcon command configures the FastPAD connection parameters.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX
addcon, dspcon, dncon, upcon
| <connection> | specifies the connection whose parameters to configure. |
| [fr_bw] | specifies the frame relay bandwidth parameters for the connection. |
This command configures connection parameters. When you enter this command, the system responds as shown in Figure 1-13.
cc7 VT StrataCom IPX 32 8.4 Jan. 30 1997 10:10 PST
Conn: 31.2.B.1 ca12 9.1.B.1 9.6
MIR CIR VC Q Depth PIR Cmax ECN QThresh QIR FST
11.6/11.6 11.6/11.6 2048/2048 11.6/11.6 10/10 1024/1024 11.6/11.6 n
% Util: 100/100
Owner: LOCAL Restriction: NONE COS: 0 Status: New Conn
Group: NONE Priority: N/A TestRTD: 0 msec
Path: cc7 19-- 6.2cc1 6.3-- 2.2ca13 1.3-- 13ca12
Pref: Not Configured
cc7 FTC: OK ca12 FTC: OK
FTI: OK FTI: OK
FastPAD: OK FastPAD: OK
This Command: cnffpcon 31.2.B.1 ca12 9.1.B.1
Enter FRP parameters (mir/oe_mir * ...):
The cnffpddelay command configures thresholds for severe congestion (Sc) and mild congestion (Mc) on the FastPAD.
Jobs: No Log: Lock: Node Type: IPX, IGX
none
| <slot.port.subslot.subport> | specifies the FTC port and subport connected to the FastPAD for configuring the Sc and Mc. |
| <Sc> | severe congestion |
| <Mc> | mild congestion |
pubsigx1 TN StrataCom IGX 32 8.4 Jan. 20 1997 14:07 GMT Port: 8.1.7.2[FAILED ] Configured Clock: 256.0 Kbps Rcv Clocking: EXTERNAL Measured Clock: N/A Xmt Clocking: EXTERNAL Data Coding: NRZ Interface: V.35 Signalling Protocol STRATA LMI Interface Control Template T391 Link Intg Timer 10 T392 Polling Verif Timer 15 Lead State N391 Full Status Poll Cycle 6 CTS ON N392 Error Threshold 3 DSR ON Monitored Events Count 4 DCD ON Severe Congestion (Sc) 64000 (512000) Mild Congestion (Mc) 57600 (460800) This Command: cnffpddelay 8.1.7.2 Sc[64000]:
The cnffppvc command configures the FastPAD bc/bc PVC parameters.
Jobs: No Log: Lock: Node Type: IPX, IGX
none
| <slot.port.subslot.subport.dlci> | specifies the FTC or FTM port, subport, and DLCI of the FastPAD. |
| <bc> | |
| <bc> |
The cnffpmap command configures the FastPAD map table.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX
cpyfpmap
| <slot.port> | specifies the FTC or FTM port connected to the FastPAD. |
This command configures FastPAD map table. The map table contains the dialing plan for the FastPAD. When you enter this command, the system responds with the following:
cc7 VT StrataCom IPX 32 8.4 Jan. 30 1997 10:14 PST Index # DLCI Slot Index # DLCI Slot Index # DLCI Slot Jump: [000] 9915 0991 05 [014] FFFF 1023 15 [028] FFFF 1023 15 [001] 0182 0018 02 [015] FFFF 1023 15 [029] FFFF 1023 15 [002] 0528 0052 08 [016] FFFF 1023 15 [030] FFFF 1023 15 [003] 0186 0018 06 [017] FFFF 1023 15 [031] FFFF 1023 15 [004] 0188 0018 08 [018] FFFF 1023 15 [032] FFFF 1023 15 [005] 0524 0052 04 [019] FFFF 1023 15 [033] FFFF 1023 15 [006] 0526 0052 06 [020] FFFF 1023 15 [034] FFFF 1023 15 [007] 0528 0052 08 [021] FFFF 1023 15 [035] FFFF 1023 15 [008] 0528 1023 09 [022] FFFF 1023 15 [036] FFFF 1023 15 [009] FFFF 1023 15 [023] FFFF 1023 15 [037] FFFF 1023 15 [010] FFFF 1023 15 [024] FFFF 1023 15 [038] FFFF 1023 15 [011] FFFF 1023 15 [025] FFFF 1023 15 [039] FFFF 1023 15 [012] FFFF 1023 15 [026] FFFF 1023 15 [040] FFFF 1023 15 [013] FFFF 1023 15 [027] FFFF 1023 15 [041] FFFF 1023 15 This Command: cnffpmap 31.2 Next Command:
The cnffpport command configures the FastPAD port parameters.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
dspftcport, dnftcport, upftcport
| <slot.port.subslot.subport> | specifies the port. |
| <parameter number> | specifies the number of the parameter to change. |
| <parameter value> | specifies the new value to enter. |
This command configures port parameters for the FastPAD port. When you enter this command, the system responds as in the screen example.
cc7 VT StrataCom IPX 32 8.4 Jan. 30 1997 10:16 PST
FastPad Port Configuration
Index: 0x0000 Location: 0x30E84C40
Port in Use : 01 Port Type : 02 Conn Exist : 01
Phy Port Code : 00 Port Code : 00 Abs Rate : 07
Data Parameters
[01] Mode : 00 [02] Baud Rate : 06 [03] Underrun Fill : 7E
[04] Clock Stop FC : 00 [05] Transmit Clock: 00 [06] Local CTS : 01
[07] Local CTS Dly : 00 [08] Local DSR : 01 [09] Local DCD : 01
[10] Hunt Group Mem: 01 [11] Dest Switch Nm: 01 [12] Dest Port Nm : 03
[13] Dest Slot/Chnl: 00 [14] Call Timer : 05 [15] Enable Channel: 01
[16] Initiate Calls: 01 [17] Allocate BW : 00 [18] Intrframe Fill: 00
[19] DPLL Mode : 00 [20] Set DE on Data: 00 [21] Async In Timer: 05
[22] Checksum : 00 [23] Sync Pattern : 0000
This Command: cnffpport 31.2.B.1
Enter parameter number to change (DEL to quit):
Enter the parameter number to make a change.
The cnffpsys command configures the FastPAD system parameters.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
dspftcport, dnftcport, upftcport
| <slot.port> | specifies the port. |
| <parameter number> | specifies the number of the parameter to change. |
| <parameter value> | specifies the new value to enter. |
This command configures system parameters for the FastPAD port. When you enter this command, the system responds with the following:
cc7 VT StrataCom IPX 32 8.4 Jan. 30 1997 10:17 PST
FastPad Configuration
Index: 0x0000 Location: 0x30E9D0B2
FPD in Use : 01 Conn State : 01 FPD Name : cc7FP
Alarm Status : 00 Switched Conn : 01 FPD Index : 05
IPX Slot Nm : 1F FTC Port Nm : 01 Link Int : 01
Link Rate : 0C Card Dsc Index: 00 Avail SwVoice : 00
Sfail/Nack : 00/00 TmOut/OutOfSeq: 00/00 Unknown/Q len : 00/00
System Parameters
[04] Ring Freq : 00 [05] Spd Dial Digit: 04 [06] Country Code : 0100
[07] Line Mgmt Ptcl: 02 [08] Local Swtch Nm: 0C [09] Local Port Nm : 51
[10] Inquire Poll : 05 [11] Full Stat Poll: 05 [12] Min Frame Size: 22
[13] Max Frame Size: 43 [14] Jitter Buf Sz : 00 [15] User Lockout : 01
Link Parameters
[16] Clock : 00 [17] Rate : 0C [18] Bandwidth : 8000
[19] Data Card Slot: FF [20] Data Card Chnl: 00 [21] Bundled DLCI : 1000
This Command: cnffpsys 31.2
Enter parameter number to change (DEL to quit)
Enter the parameter number to make a change.
The cnffstparm command configures the ForeSight parameters for frame relay ports.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
cnffrcon
No line or port number need be entered.
This command configures the ForeSight parameters for frame relay ports. This command only has an effect if the frame relay ForeSight option is enabled. The parameter values set by this command apply to all frame relay connections enabled with ForeSight. Therefore, these parameters must be configured on each node in the network that has ForeSight connections. Table 1-10 lists the parameters. The cnffrcon command enables ForeSight on a connection.
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 15:41 PST 1 FRP/FTC Increase Rate [ 10] (%) 2 FRP/FTC Decrease Rate [ 87] (%) 3 FRP Fast Decrease Rate [ 50] (%) 4 RTD Measurement Time [ 5] (secs) 5 Default RTD [ 100] (msecs) 6 Minimum RTD [ 40] (msecs) 7 Maximum RTD [ 250] (msecs) 8 FECN for congested mins [ 50] (%) 9 QIR Time-out [ 10] (secs) 10 Max TstDelay Retries [ 2] (dec) This Command: cnffstparm Enter parameter index:
sw66 TN StrataCom BPX 15 8.4.a4 Aug. 28 1997 23:50 GMT
1 FST Increase Rate [ 10] (%)
2 FST Decrease Rate [ 93] (%)
3 FST Fast Decrease Rate [ 50] (%)
4 RTD Measurement Time [ 5] (secs)
5 Default RTD [ 100] (msecs)
6 Minimum RTD [ 40] (msecs)
7 Maximum RTD [ 250] (msecs)
8 FECN for congested mins [ 50] (%)
9 QIR Time-out [ 244] (secs)
10 Max TstDelay Retries [ 2] (dec)
Last Command: cnffstparm
Next Command:
| No. | Parameter | Description | Default |
|---|---|---|---|
| 1 | FRP Increase Rate | If free bandwidth is available, the rate at which FRP increases transmission (as a percentage of MIR). | 10% |
| 2 | FRP Decrease Rate | If free bandwidth becomes unavailable, the rate at which FRP decreases transmission (as a percentage of current rate). | 87% |
| 3 | FRP Fast Decrease Rate | If a cell is dropped or the TxQ is full, the rate at which FRP decreases transmission (as a percentage of current rate). | 50% |
| 4 | RTD Measurement Time | The polling interval for measuring round-trip delay on each frame relay PVC. | 5 sec. |
| 5 | Default RTD | The default RTD the connection uses before RTD is measured. | 100 ms. |
| 6 | Minimum RTD | Min. value used for RTD in FR calculation regardless of measured RTD. | 40 ms. |
| 7 | Maximum RTD | Max. value used for RTD in FR calculation regardless of measured RTD. | 250 ms. |
| 8 | FECN for congested mins | When this % of packets received have the EFCN bit set, a congested minutes field in the dspfrport command is indicated. | 50% |
| 9 | QIR Time-out | Interval after which if PVC is idle, will reset the allowable transmit rate to QIR. | 10 secs. |
| 10 | ?? |
The cnflan command configures node communication parameters.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
upln, dnln, cnfln
| <IPAdd> | Specifies the Internet address of the node used in the TCP/IP protocol |
| <IP subnet mask> | Specifies a 32-bit mask that contains information about the bit lengths of the subnet ID and host ID address fields. The format of this field uses 1s for the subnet ID field and 0s for the host ID address field as defined in the TCP/IP protocol. The default value (in decimal notation) is 255 255 255.0. This mask denotes both subnet ID and host ID fields as 8-bit fields. |
| <Max. LAN Transmit Unit> | BPX only: typical amount is 1500 bytes. |
| <TCPServicePort> | Specifies the node's service point used by the transmission control protocol (TCP). |
| <GatewayIPAddr> | Specifies the Internet gateway address |
This command configures node communication parameters, so the node can communicate with a StrataView Plus terminal over an Ethernet LAN using TCP/IP protocol. The parameters all contain address information about the Ethernet TCP/IP network that connects the StrataView Plus station to an IPX, IGX, or BPX. The values must conform to those of the network. The network administrator can supply the parameters.
beta TRM YourID:1 IPX 32 8.4 Jan. 15 1997 14:44 MST
Active IP Address: 192.0.0.0
IP Subnet Mask: 255.255.255.0
TCP Service Port: 5120
Default Gateway IP Address: None
Maximum LAN Transmit Unit: 1500
Ethernet Address: 00.E0.07.00.00.00
LAN is not available on the PCC
Last Command: cnflan
Next Command:
The cnflnparm command configures several parameters for ATM lines originating on the BPX.
Jobs: No Log: Yes Lock: Yes Node Type: BPX
upln, dnln, cnfln
| <slot.port> | specifies the line to configure in the format slot.port for the ASI-0 card. |
| <option 1 - 4> | specifies the parameter to configure. |
This command configures the circuit line alarm integration times for RED and YELLOW circuit line alarms. These integration times are specified in milliseconds and should be set to correspond to the local carrier's alarm integration times. Carrier integration times are typically 800 ms. to 1500 ms for RED Alarm and 1500 to 3000 milliseconds for YELLOW Alarm. The allowable range for these parameters are 60 to 3932100 milliseconds.
You can also set the queue depth for the two queues associated with the ASI-0 card, the constant bit rate (CBR) queue and the Variable Bit Rate (VBR) queue. The queue depths may be increased to 16,000 bytes per queue.
When you enter this command system responds with the screen in Figure 1-20. This command is quite similar to the Configure Circuit Line command.
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 15:45 PST CLN 7 Parameters 1 Red Alarm - In/Out [ 1000 / 2000] (Dec) 2 Yel Alarm - In/Out [ 1000 / 2000] (Dec) This Command: cnflnparm 7 Which parameter do you wish to change:
The cnflnsigparm command configures the line signalling parameters.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
cnflnparm, cnflnstats, dsplnstatcnf, dsplnstathist, upln, dnln, cnfln
| <parameter number> | specifies the number of the parameter to change. |
| <parameter value> | specifies the new value to enter. |
This command configures the line signalling parameters associated with a line. When you enter this command, the screen responds with the following:
cc2 LAN StrataCom IPX 32 8.4 Jan. 30 1997 11:16 PST 1 CDP & CIP Heartbeat [ 2] (sec) 2 CDP & CIP Sig. Polling Rate [ 10] (sec) 3 CDP & CIP Default Inband Sig Delay [ 96] (msec) 4 CDP & CIP Default Inband Playout Delay [ 200] (msec) 5 CDP & CIP Default Pulse Sig Delay [ 96] (msec) 6 CDP & CIP Default Pulse Playout Delay [ 200] (msec) 7 CIP Number of Packet Slices [ 1] 8 CDP & CIP Packet Rate [ 200] (pkt/sec) 9 CDP & CIP Condition CCS Lines? [ YES] 10 CIP Default Inband Min. Wink [ 140] (msec) 11 CIP Default Pulse Min. Wink [ 140] (msec) This Command: cnflnsigparm Which parameter do you wish to change
The cnflnstats command configures statistics collection for the specified line.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
dsplnstatcnf, dsplnstathist
| <line> | specifies the port to configure. |
| <stat> | specifies the type of statistic to enable/disable. |
| <interval> | specifies the time interval of each sample (1 - 255 minutes). |
| <e|d> | enables/disables a statistic. 'E' to enable; 'D' to disable. |
| [samples] | specifies the number of samples to collect (1 - 255). |
| [size] | specifies the number of bytes per data sample (1, 2 or 4). |
| [peaks] | enables the collection of one minute peaks. 'Y' to enable; 'N' to disable. |
This command configures parameters for line statistic collection. It is basically a debug tool and should not be required for everyday use. It permits customizing statistics collected on each line. The following table lists the statistics by type.
Not all statistic types are available for all lines. Only valid statistics are displayed for the user to select from, the others appear in gray.
| Statistic Type | Statistic | Line Type |
|---|---|---|
| 1 | Bipolar Violations | E1 and T1 |
| 2 | Frame Slips | E1 and T1 |
| 3 | Out of Frames | E1 and T1 |
| 4 | Loss of Signal | E1 and T1 |
| 5 | Frame Bit Errors | E1 only |
| 6 | CRC Errors | E1 only |
| 7 | Out of Multi-Frames | E1 only |
| 8 | All Ones in Timeslot 16 | E1 only |
Figure 1-22 illustrates the screen displayed after entering cnflnstats.
cc2 LAN StrataCom IPX 32 8.4 Jan. 30 1997 11:20 PST Line Statistic Types 1) Bipolar Violations 2) Frames Slips 3) Out of Frames 4) Losses of Signal 5) Frames Bit Errors 6) CRC Errors 7) Out of Multi-Frames 8) All Ones in Timeslot 16 Last Command: cnflnstats 15 6 255 e Next Command:
The cnfmxbutil command configures the IPX MUXBUS utilization factor for each FRP.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
none
| <slot number> | specifies the slot number of the associated FRP card. |
| <percentage> | specifies the percent of MUXBUS bandwidth to allocate. |
This command configures the MUXBUS utilization factor. A certain amount of MUXBUS bandwidth is allocated by system software for each FRP in an IPX node. Since the maximum data rate for an FRP is 2 Mbps, this is also the maximum amount of MUXBUS bandwidth reserved for the FRP.
In many applications, each of the four FRP ports is configured for a large number of 56 or 64 Kbps connections. System software adds up the bandwidth required for all the connections, multiplies by 121% to reserve extra bandwidth for overhead, then subtracts this amount from the total available MUXBUS bandwidth.
However, statistical full utilization is not often required on ports with a large number of connections and the MUXBUS bandwidth reserved may be reduced further. In nodes equipped with a T3 or E3 ATMT card, much of the MUXBUS bandwidth may be assigned to the ATM trunk and the remaining MUXBUS bandwidth may need to be allocated carefully.
Prior to release 7.1, the MUXBUS utilization factor was configurable only on a per-node basis using the cnfnodeparm command. All FRPs had to be configured the same. This command permits assigning the utilization factor for each FRP in the node on a slot by slot basis.
See Figure 1-23 for a sample screen. N/A is displayed for all slots not equipped with an FRP. Once the slot is selected, the system displays the message "Enter Utilization Factor." The allowable range is from 1 to 250% with a default of 121%. The extra 21% for the default is used to cover the overhead involved in encapsulating the frame relay frame in the FastPacket or ATM cell.
gamma SV+ SuperUser IPX32 Rev: 8.4 Jan. 14 1997 14:27 PDT
Slot 1: N/A Slot 9: N/A Slot 17: 121% Slot 25: N/A
Slot 2: N/A Slot 10: N/A Slot 18: 121% Slot 26: N/A
Slot 3: N/A Slot 11: N/A Slot 19: N/A Slot 27: N/A
Slot 4: N/A Slot 12: N/A Slot 20: N/A Slot 28: N/A
Slot 5: N/A Slot 13: N/A Slot 21: N/A Slot 29: N/A
Slot 6: N/A Slot 14: N/A Slot 22: N/A Slot 30: N/A
Slot 7: N/A Slot 15: N/A Slot 23: N/A Slot 31: N/A
Slot 8: N/A Slot 16: N/A Slot 24: N/A Slot 32: N/A
This Command: cnfmxbutil
Enter Slot:
Sets a variety of general parameters for the nodes in a network.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
none
The cnfnodeparm command lets you change some of the node's system parameters. The parameters you can set with cnfnodeparm are not closely related. Table 1-12 and Table 1-13 describe the parameters for the IPX/IGX and BPX nodes, respectively. After each table, an applicable set of cnfnodeparm screens appears in the Example sections. The defaults for the parameters are selected by Cisco engineering to operate under normal network conditions. With few exceptions, you should change them only with the guidance of the WANBU TAC.
| Index | Parameter | Description | Default * |
|---|---|---|---|
| 1 | Update Initial Delay (sec.) | Specifies a factor for generating a delay before conditional updates are transmitted to the network after a controller card switch-over. The Update Initial Delay is multiplied by the number of nodes in the network. | 5000 (D) |
| 2 | Update Per-Node Delay (ms.) | Specifies the delay between transmission of conditional updates to the nodes. | 30000 (D) |
| 3 | Comm. Break Test Delay (ms.) | Normal interval between tests for communication break on any node. | 30000 (D) |
| 4 | Comm. Break Test Offset | Factor between number of communication test failures and test successes to declare a node in communication break condition. | 10 (D) |
| 5 | Network Timeout Period | Number of milliseconds to wait for a response to a communication test transmission before declaring a failure. The maximum is four failures. | 1700 (D) |
| 6 | Network Inter-p Period | In inter-domain connections, Network Inter-p Period is the number of milliseconds to wait for a response to a communication test transmission before declaring a failure. The maximum is four failures | 4000 (D) |
| 7 | Network Sliding Window Size | Controls the number of control card messages that the node can simultaneously transmit to the network. This parameter defines the number of no acknowledgments outstanding on a controller before NACKS is declared. | 1 (D) |
| 8 | Number of Normal Timeouts | For intra-domain connections: Number of Normal Timeouts is the maximum number of normal network re-transmissions before the node signals a communication break. | 7 (D) |
| 9 | Number of Inter-p Timeouts | For inter-domain connections: Number of Inter-p Timeouts is the maximum number of normal network re-transmissions before the node signals a communication break. | 3 (D) |
| 10 | Number of Satellite Timeouts | Maximum number of satellite network re-transmissions before the node signals a communication break. | 6 (D) |
| 11 | Number of Blind Timeouts | Maximum number of communication fail timeouts and re-transmissions before the node declares a communication failure (CF). One successful acknowledgment clears CF. | 4 (D) |
| 12 | Number of CB Msg Timeouts | Number of communication break timeouts and re-transmissions before the node declares a communication break condition (CB). One successful acknowledgment clears the CB condition. | 2 (D) |
| 13 | Comm. Fail Interval (ms.) | Minimum time allocated for communication fail testing of all trunks terminating on the local node. | 10,000 (D) |
| 14 | Comm. Fail Multiplier | Number of Comm. Fail Intervals to skip for good lines. | 3 (D) |
| 15 | Temperature Threshold (× C.) | Temperature in the enclosure that causes an over-temperature alarm to go to the controller card. | 50 (D) |
| 16 | NPC Redundancy Configured | A "y" indicates a redundant controller card is required. The absence of a redundant controller card generates an alarm. | Y |
| 17 | MT3 | OBSOLETE | |
| 18 | Network Packet TX Rate | Rate for transmitting control card packets to the network. The range is a series of discreet values: 100 200 333 500 1000 1100 1200 1333 1500 2000. The units of measure are packets per second (pps). The purpose of this parameter is to prevent the control card from flooding the trunk with packets. | 500 pps |
| 19 | Statistics Memory (x 10 KB) | Specifies the amount of controller memory to allocate for statistics collection. | 76 (D) |
| 20 | Standby Update Timer | Specifies how often to send update messages to standby controller | 10 (D) |
| 21 | Stby Updts Per Pass | Number of messages that can be sent to standby NPC for each update interval. | 30 (D) |
| 22 | Gateway ID Timer | An inter-domain rerouting timer. How often to look for junction nodes for new route. | 30 (D) |
| 23 | GLCON Alloc Timer | Another inter-domain rerouting timer controlling gateway LCON function. | 30 (D) |
| 24 | Comm Fail Delay | Number of milliseconds to wait to start detecting communication failures after a controller switch-over. | 60 (D) |
| 25 | Nw. Hdlr Timer (msec) | Network handler timer determines how long to wait to send messages to or receive messages from a remote node. | 50 (D) |
| 26 | CBUS Delay | Specifies the minimum number of milliseconds the NPC or NPM must wait before it places the next command on the CBUS. | 20 (D) |
| 27 | SNMP | Enables maintenance logging of global SNMP messages. These SNMP events are not errors but any GET, SET, and so on. Output goes to a printer connected to the node's auxiliary port or a terminal server (accessible via telnet). Without a connected output device, the parameter is meaningless. | y=yes |
| 28 | TFTP Grant Delay | The number of seconds the node waits before re-sending a TFTP request after a TFTP error has occurred. This field is display-only: you set the value in StrataView Plus. | 1 |
| 29 | TFTTP ACK Timeout | The number of seconds the node waits for an acknowledgment of a TFTP request before it declares the request as timed out. This field is display-only: you set the value in StrataView Plus. | 10 |
| 30 | TFTP Write retires | The number of times the node retries a TFTP operation (not just writes) after a failed attempt. This field is display-only: you set the value in StrataView Plus. | 3 |
| 31 | FRP/FRM Link Status Alarm | Determines whether a signaling failure on an FRP or FRM port causes a major alarm. This parameter applies to any port configured as an NNI. | y=yes |
| 32 | Job Lock Timeout | The range is 1-1000 seconds. The default of 0 disables this parameter. | 0 |
| 33 | Max Via LCONs | The maximum number of "via" connections a via node can support. The default is the maximum and should remain the default under normal operating conditions. | 5000 on an IPX node
20000 on an IGX node |
| 34 | Max Blind Segment Size | The maximum size of each segment of a blind message. (The full message may be longer than the segment, especially in a large network.) A blind message is a message the local node sends to the far end node when you execute addtrk. If the trunk has many errors, smaller message segments increase the possibility of a successful addtrk. Under normal conditions, this parameter should remain the default. | 3570 |
| 35 | Max Nib Xmit Msgs | Maximum number of memory blocks available for messages that are awaiting transmission. Under normal conditions, this parameter should remain the default. | 3000 |
| 36 | Max stby update Q size | Maximum number of update messages that can reside in queues awaiting transmission to the standby processor. Only rare circumstances could provide a reason to change this parameter, so do not change it without first consulting the WANBU TAC. | 5000 |
| |||
The example shows the two screens required to show all cnfnodeparm parameters on an IPX node.
pubsipx1 TN StrataCom IPX 16 8.4 May 9 1997 09:30 GMT
1 Update Initial Delay [ 5000] (D) 16 CC Redundancy Cnfged [ Y] (Y/N)
2 Update Per-Node Delay [30000] (D) 17 MT3 Pass Through Relay [ Y] (Y/N)
3 Comm-Break Test Delay [30000] (D) 18 Nw Pkt Tx Rate (pps) [ 500] (D)
4 Comm-Break Test Offset [ 10] (D) 19 Stats Memory (x 10KB) [ 61] (D)
5 Network Timeout Period [ 1700] (D) 20 Standby Update Timer [ 1] (D)
6 Network Inter-p Period [ 4000] (D) 21 Stby Updts Per Pass [ 30] (D)
7 NW Sliding Window Size [ 1] (D) 22 Gateway ID Timer [ 30] (D)
8 Num Normal Timeouts [ 7] (D) 23 GLCON Alloc Timer [ 30] (D)
9 Num Inter-p Timeouts [ 3] (D) 24 Comm Fail Delay [ 60] (D)
10 Num Satellite Timeouts [ 6] (D) 25 Nw Hdlr Timer (msec) [ 100] (D)
11 Num Blind Timeouts [ 4] (D) 26 CBUS Delay (msec) [ 20] (D)
12 Num CB Msg Timeouts [ 2] (D) 27 SNMP Event logging [ Y] (Y/N)
13 Comm Fail Interval [10000] (D) 28 TFTP Grant Delay (sec) [ 1] (D)
14 Comm Fail Multiplier [ 3] (D) 29 TFTP ACK Timeout (sec) [ 10] (D)
15 Temperature Threshold [ 50] (D) 30 TFTP Write Retries [ 3] (D)
This Command: cnfnodeparm
Continue? y
pubsipx1 TN StrataCom IPX 16 8.4 May 9 1997 09:31 GMT
31 FRP Link Status Alarm [ Y] (Y/N)
32 Job Lock Timeout [ 0] (D)
33 Max Via LCONs [ 5000] (D)
34 Max Blind Segment Size [ 3570] (D)
35 Max Nib Xmit Msgs [ 1000] (D)
36 Max Stby Update Q Sz [ 5000] (D)
This Command: cnfnodeparm
Enter parameter index:
| Index | Parameter | Description | Default * |
|---|---|---|---|
| 1 | Update Initial Delay (sec.) | This delay, multiplied times the number of nodes in the network, is the delay before conditional updates are transmitted to the network after a BCC switchover. | 5000 seconds |
| 2 | Update Per-Node Delay (ms.) | Delay between transmission of conditional updates to nodes. | 30000 msecs |
| 3 | Comm. Break Test Delay (ms.) | Interval between tests for communication breaks on any node. | 30000 msecs |
| 4 | Comm. Break Test Offset | Factor between number of comm. test failures and successful tests to declare a node in comm. break condition. | 10 (D) |
| 5 | Network Timeout Period | The time a node waits for a response to a communication test transmission before it declares a failure. Four failures allowed. | 1700 (D) |
| 6 | Network Inter-p Period | The time a node waits for a response to a communication test transmission on inter-domain connections before it declares a failure. The maximum number failures is four. | 4000 (D) |
| 7 | NW Sliding Window Size | Controls the number of BCC messages that can be transmitted simultaneously. Defines # of no acknowledgments outstanding on controller before NACKS declared. | 1 (D) |
| 8 | Num. Normal Timeouts | Number of normal network re-transmissions allowed before issuing a comm. break condition (for intra-domain connections). | 7 (D) |
| 9 | Num. Inter-p Timeouts | Number of normal network re-transmissions allowed before issuing a comm. break condition (for inter-domain connections). | 3 (D) |
| 10 | Num. Satellite Timeouts | Number of satellite network re-transmissions allowed before issuing a comm. break. | 6 (D) |
| 11 | Number of Blind Timeouts | Number of comm. fail timeouts and re-transmissions before declaring comm. fail. One successful acknowledgment clears CF. | 4 (D) |
| 12 | Number of CB Msg Timeouts | Number of comm. break timeouts and re-transmissions before declaring a comm. break (CB) condition. One successful acknowledgment clears CB. | 2 (D) |
| 13 | Comm. Fail Interval (ms.) | Minimum time allocated for communication fail testing of all trunks terminating on this node. | 10,000 (D) |
| 14 | Comm. Fail Multiplier | Number of Comm. Fail Intervals to skip for good lines. | 3 (D) |
| 15 | BCC Redundancy Configured | Yes indicates a redundant controller card is required or an alarm will be generated. | Y |
| 16 | Stats Memory (x 10 KB) | The amount of controller memory to allocate to statistics collection. | 76 (D) |
| 17 | Standby Update Timer | Determines how often to send update messages to standby controller | 10 (D) |
| 18 | Stby Updts Per Pass | Number of messages that can be sent to standby NPC for each update interval. | 30 (D) |
| 19 | Gateway ID Timer | An inter-domain rerouting timer that determines how often to look for junction nodes for a new route. | 30 (D) |
| 20 | GLCON Alloc Timer | Another inter-domain rerouting timer controlling gateway LCON function. | 30 (D) |
| 21 | Comm Fail Delay | Timer to determine how soon after controller switchover to start detecting comm. fail. | 60 (D) |
| 22 | Nw. Hdlr Timer (msec) | Network handler timer determines how long to wait to send messages to or receive messages from a remote node. | 50 (D) |
| 23 | SAR BCC Transmit Rate | Transmit data rate for BCC traffic to standby BCC (Kbps). | 560 (D) |
| 24 | SAR High Transmit Rate | Transmit data rate for BCC traffic to other BCC nodes (Kbps). | 280 (D) |
| 25 | SAR Low Transmit Rate | Transmit data rate for BCC traffic to ICC nodes (Kbps). | 56 (D) |
| 26 | SAR VRAM Cngestn Limit | BCC traffic receive queue congestion threshold that will cause cell discards. | 7680 (D) |
| 27 | SAR VRAM Cell Discard | BCC traffic receive queue discard amount in cells. | 256 (D) |
| 28 | ASM Card Cnfged | Yes indicates an Alarm/Status Monitor card is required or an alarm will be generated. | Y |
| 29 | TFTP Grant Delay (sec) | The number of seconds the node waits before re-sending a TFTP request after a TFTP error has occurred. This field is display-only: you set the value in StrataView Plus. | 1 |
| 30 | TFTP ACK Timeout (sec) | The number of seconds the node waits for an acknowledgment of a TFTP request before it declares the request as timed out. This field is display-only: you set the value in StrataView Plus. | 10 |
| 31 | TFTP Write Retries | The number of times the node retries a TFTP operation (not just writes) after a failed attempt. This field is display-only: you set the value in StrataView Plus. | 3 |
| 32 | SNMP Event logging | Enables maintenance logging of global SNMP messages. These SNMP events are not errors but any GET, SET, and so on. Output goes to a printer connected to the node's auxiliary port or a terminal server (accessible via telnet). Without a connected output device, the parameter is meaningless. | y=yes |
| 33 | Job Lock Timeout | The range is 1-1000 seconds. The default of 0 disables this parameter. | 0 |
| 34 | Max Via LCONs | The maximum number of "via" connections a via node can support. The default is the maximum for the node and should remain the default under normal operating conditions. | 50000 |
| 35 | Max Blind Segment Size | The maximum size of each segment of a blind message. (The full message may be longer than the segment, especially in a large network.) A blind message is a message the local node sends to the far end node when you execute addtrk. If the trunk has many errors, smaller message segments increase the possibility of a successful addtrk. Under normal conditions, this parameter should remain the default. | 3570 |
| 36 | Max XmtMemBlks per NIB | Maximum number of memory blocks available for messages that are awaiting transmission. Under normal conditions, this parameter should remain the default. | 3000 |
| 37 | Max Stby Update Q Sz | Maximum number of update messages that can reside in queues awaiting transmission to the standby processor. Only rare circumstances could provide a reason to change this parameter, so do not change it without first consulting the WANBU TAC. | 5000 |
| |||
This example illustrates the two screens required to show all cnfnodeparm parameters on a BPX node.
sw45 TN StrataCom BPX 15 8.4 Aug. 27 1997 18:25 PDT
1 Update Initial Delay [ 5000] (D) 16 Stats Memory (x 10KB) [ 61] (D)
2 Update Per-Node Delay [30000] (D) 17 Standby Update Timer [ 10] (D)
3 Comm-Break Test Delay [30000] (D) 18 Stby Updts Per Pass [ 50] (D)
4 Comm-Break Test Offset [ 10] (D) 19 Gateway ID Timer [ 30] (D)
5 Network Timeout Period [ 1700] (D) 20 GLCON Alloc Timer [ 30] (D)
6 Network Inter-p Period [ 4000] (D) 21 Comm Fail Delay [ 60] (D)
7 NW Sliding Window Size [ 1] (D) 22 Nw Hdlr Timer (msec) [ 50] (D)
8 Num Normal Timeouts [ 7] (D) 23 SAR CC Transmit Rate [ 560] (D)
9 Num Inter-p Timeouts [ 3] (D) 24 SAR High Transmit Rate [ 280] (D)
10 Num Satellite Timeouts [ 6] (D) 25 SAR Low Transmit Rate [ 56] (D)
11 Num Blind Timeouts [ 4] (D) 26 SAR VRAM Cngestn Limit [ 7680] (D)
12 Num CB Msg Timeouts [ 5] (D) 27 SAR VRAM Cell Discard [ 256] (D)
13 Comm Fail Interval [10000] (D) 28 ASM Card Cnfged [ Y] (Y/N)
14 Comm Fail Multiplier [ 3] (D) 29 TFTP Grant Delay (sec) [ 1] (D)
15 CC Redundancy Cnfged [ N] (Y/N) 30 TFTP ACK Timeout (sec) [ 10] (D)
This Command: cnfnodeparm
Continue? y
sw45 TN StrataCom BPX 15 8.4 Aug. 27 1997 18:26 PDT
31 TFTP Write Retries [ 3] (D)
32 SNMP Event logging [ Y] (Y/N)
33 Job Lock Timeout [ 60] (D)
34 Max Via LCONs [50000] (D)
35 Max Blind Segment Size [ 3570] (D)
36 Max XmtMemBlks per NIB [ 3000] (D)
37 Max Stby Update Q Sz [ 5000] (D)
This Command: cnfnodeparm
Enter parameter index:
The cnfnwip command configures an IP address and subnet mask for the node.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
none
| <IPAddr> | IP address of the node: the format is nnn.nnn.nnn.nnn, where nnn can be 1-255 |
| <IPSubnetMask> | subnet mask: the format is nnn.nnn.nnn.nnn |
An example of this command is:
cnfnwip 199.35.96.217 255.255.255.0
where 199.35.96.217 is the IP address, and 255.255.255.0 is the subnet mask.
The network IP address and subnet mask support statistics collection for StrataView Plus. The cnfnwip command defines the IP address the system uses to pass messages between StrataView Plus and the node. The Statistics Master process in StrataView Plus Network collects statistics. The Statistics Manager requests and receives statistics using TFTP Get and Put messages. These TFTP messages pass between the node and the Statistics Master using IP Relay. (See the cnfstatmast description for details on setting the Statistics Master address.)
axiom TN Bootzilla IGX 32 8.4 Jan. 5 1997 18:25 GMT Active Network IP Address: 169.134.90.106 Active Network IP Subnet Mask: 255.255.255.0 Last Command: cnfnwip 169.134.90.106 255.255.255.0 Next Command:
The cnfportstats command configures parameters for frame relay ports.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
none
| <port> | specifies the port to configure. |
| <stat> | specifies the type of statistic to enable/disable. |
| <interval> | specifies the time interval of each sample (1 - 255 minutes). |
| <e|d> | enables/disables a statistic. 'E' to enable; 'D' to disable. |
| [samples] | specifies the number of samples to collect (1 - 255). |
| [size] | specifies the number of bytes per data sample (1, 2 or 4). |
| [peaks] | enables the collection of one minute peaks. 'Y' to enable; 'N' to disable. |
The cnfportstats command configures frame relay port parameters. Primarily, it is for debugging. Table 1-14 lists the configurable statistics. Not all statistic types are apply to all ports. Refer to Figure 1-25 and Figure 1-26 for examples.
Figure 1-26 shows that the selected statistic is 33--transmitted bytes while the ingress LMI is showing a failed condition. Following the port number and statistic number (33) on the command line, the parameters are: the interval, the enable for this statistic, the number of samples, and so on.
| Type | Statistic |
|---|---|
| 1-4 | Total frames and bytes transmitted and received. |
| 5-6 | Frames transmitted with FECN and BECN set. |
| 7-10 | Frames received with problems: CRC errors, invalid format, frame alignment errors, wrong length frames. |
| 11 | Number of direct memory access (DMA) overruns on a frame relay port that are probably due to excessive user-data input. |
| 12-17 | LMI counts on UNI ports. These include status inquiries, status transmit and update requests, invalid inquiries, and LMI link timeouts. |
| 18 | Frames received with DLCIs in error. |
| 19 | Frames dropped with DE bit set. |
| 20-24 | LMI counts on NNI ports: status inquiries, status receive and update requests, LMI link timeouts, keepalive sequence errors. |
| 25-26 | Frame and byte count totals for Consolidated Link Layer Message (CLLM) frames that transmit ForeSight messages. |
pubsigx1 TN StrataCom IGX 32 8.4 Jan. 5 1997 17:21 GMT Port Statistic Types 1) Frames Received 14) LMI UNI Status Update Count 2) Frames Transmitted 15) LMI Invalid Status Enquiries 3) Bytes Received 16) LMI UNI Link Timeout Errors 4) Bytes Transmitted 17) LMI UNI Keepalive Sequence Errors 5) Frames Transmitted with FECN 18) Receive Frames Undefined DLCI Count 6) Frames Transmitted with BECN 19) DE Frames Dropped 7) Receive Frame CRC Errors 20) LMI NNI Status Enquiries 8) Invalid Format Receive Frames 21) LMI NNI Status Receive Count 9) Receive Frame Alignment Errors 22) LMI NNI Status Update Count 10) Illegal Length Receive Frames 23) LMI NNI Link Timeout Errors 11) Number of DMA Overruns 24) LMI NNI Keepalive Sequence Errors 12) LMI UNI Status Enquiries 25) CLLM Frames Transmitted 13) LMI UNI Status Transmit Count 26) CLLM Bytes Transmitted This Command: cnfportstats 3.1 Continue?
pubsigx1 TN StrataCom IGX 32 8.4 Jan. 5 1997 17:24 GMT Port Statistic Types 27) CLLM Frames Received 28) CLLM Bytes Received 29) CLLM Failures 30) Tx Frames Discarded - Queue Overflow 31) Tx Bytes Discarded - Queue Overflow 32) Tx Frames while Ingress LMI Failure 33) Tx Bytes while Ingress LMI Failure Last Command: cnfportstats 3.1 33 2 e 2 4 y Next Command:
The cnfqstats command configures the collection of queue-based statistics for the selected node slot.
Jobs: Yes Log: Yes Lock: Yes Node Type: BPX
dspqstats
| <slot number> | specifies the shelf and slot. |
This command sets the collection interval for each of the BPX node queue-based slot statistics. The default is for no statistics to be collected. The collection interval range is 1 minute to 255 minutes (4-1/4 hours).
The cnfrobparm command sets parameters associated with the Robust Alarms feature.
Jobs: No Log: No Lock: Yes Node Type: IPX, IGX, BPX
none
| <index> | specifies the parameter to configure. |
| <value> | specifies new value to be entered for the parameter. |
This command sets Robust Alarms parameters. Robust Alarms is a protocol for node to NMS communications. When a node has statistics or alarm information to be sent to the NMS, it requires a response from the NMS as a confirmation of database update. Table 1-15 lists the parameters. Figure 1-27 illustrates the command.
| No. | Parameter | Description | Default |
|---|---|---|---|
| 1 | Robust State wakeup timer (ms.) | This state machine comes to life once a second (default). If this timer is increased, it operates less often and places less of a load on the node processor. | 10 ms. |
| 2 | Robust update timer (sec.) | Once a message has been sent to the NMS, another one will not be sent before this timer expires. | 10 sec. |
| 3 | Robust acknowledgment timeout (sec.) | An acknowledgment must be returned by the NMS within this time period or it is assumed the communications link is down. | 600 sec. |
| 4 | Robust acknowledgment reset timeout (sec.) | When the link has gone down, then is repaired, the next message will be sent after this timeout. Provides a settling time for the link. | 60 sec. |
D1.a34 TRM SuperUser IPX 16 8.4 Jan. 14 1997 15:02 PDT
Robust Parameters
1 Robust State wakeup timer (sec) .................................. 10
2 Robust update timer (sec) ........................................ 10
3 Robust acknowledge timeout (sec) .................................600
4 Robust acknowledge reset timeout (sec) ...........................60
This Command: cnfrobparm
Which parameter do you wish to change:
The cnfslotstats command configures the collection of statistics for the selected node slot.
Jobs: Yes Log: Yes Lock: Yes Node Type: BPX
dspsloterrs
| <slot number> | specifies the shelf and slot. |
This command sets the collection interval for each of the BPX node slot statistics. The default is for no statistics to be collected. The collection interval range is 1 minute to 255 minutes (4-1/4 hours).
Table 1-16 lists the nine statistics associated with each slot in the BPX. Figure 1-28 illustrates the command screen. This command is primarily a troubleshooting tool for use when hardware errors are experienced that may not be detected by the individual care self-test routines. An associated display command (dspsloterrs) is available for all users.
| Error | Description |
|---|---|
| Standby Bus Errors | Indicates a background test over the standby bus produced an error. |
| Rx Invalid Port Errors | Indicates port number was out of the range 1-3. |
| Polling Bus A Errors | Parity error occurred on this polling bus. |
| Polling Bus B Errors | Parity error occurred on this polling bus. |
| Bad Grant Errors | Error indicates arbiter did not issue a grant to send data before a timeout. |
| Tx BIP-16 Errors | Data frame transmitted had a checksum error. |
| Rx BIP-16 Errors | Data frame received with a checksum error. |
| SIU Phase Errors | Serial Interface Unit on the card did not detect the frame synch properly. |
| Bframe Errors | Errors detected in the BPX frame on the StrataBus or in a memory operation. |
You must enter the statistic type (1-9) to set the collection interval. When the command is entered, the system responds with the prompt:
"Collection Interval (1-255 minutes): __
sw81 TN StrataCom BPX 15 8.4 Feb. 1 1997 15:42 PST Card Statistics Types 1) Standby PRBS Errors 2) Rx Invalid Port Errs 3) PollA Parity Errors 4) PollB Parity Errors 5) Bad Grant Errors 6) Tx Bip 16 Errors 7) Rx Bip 16 Errors 8) Bframe parity Errors 9) SIU phase Errors 10) Rx FIFO Sync Errors 11) Poll Clk Errors 12) CK 192 Errors This Command: cnfslotstats 8
The cnftcpparm command configures the TCP parameter.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
dsptcpparm
| <network ip throttle> | specifies the number of times that the BCC card polls the LAN for attention requests. |
This command configures the amount of number of times each second that the BCC card will check the IP addressees for attention requests. Figure 1-29 illustrates the system response when the command is issued:
sw81 TN StrataCom BPX 15 8.4 Feb. 1 1997 15:46 PST NWIP Bandwidth Throttle (Kbytes/sec): 32 This Command: cnftcpparm Enter NWIP Bandwidth Throttle (Kbytes/sec):
The cnftlparm command configures the trunk based loading (TBL) parameters.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
cnfcmparm
| No. | Parameter | Description | Range | Default |
| 1 | Enable | Enables or disables automatic TBL update messages. Do not disable unless you first contact the WANBU TAC. | Yes/No | Yes |
| 2 | Normal Interval | Specifies the time interval between checks to determine if the node should send out a TBL update signaling a non-critical change in the trunk load. | 0-65000 (times 100 msecs) | 150 |
| 3 | Fast Interval | Specifies the time interval between checks to determine if the node should send out a TBL update signaling a critical change in the trunk load. | 0-65000 (times 100 msecs) | 50 |
| 4 | Low Threshold | Parameters for complex update algorithm. | 1-100% | 50 |
| 5 | High Threshold | Parameters for complex update algorithm. | 1-100% | 90 |
| 6 | Min. Percent Chg, Mid 1 | Parameters for complex update algorithm. | 1-100% | 10 |
| 7 | Min. Percent Chg, Mid 2 | Parameters for complex update algorithm. | 1-100% | 6 |
| 8 | Min. Percent Chg, Mid 3 | Parameters for complex update algorithm. | 1-100% | 3 |
| 9 | Min. Percent Chg, Upper | Parameters for complex update algorithm. | 1-100% | 2 |
| 10 | Background Updt Count | Specifies a periodic update. 0=disabled. If Background Updt Count is greater than 0, switch software multiplies it by the value you specify for Normal Interval. | 0-1000% | 0 |
| 11 | Update Algorithm | Selects the update algorithm. 0=default. 1=complex update algorithm. | 0 or 1 | 0 |
The cnftlparm command lets you control the rate of update messages related to trunk-based loading. The following example shows the screen for cnftlparm.
The following example shows the screen for cnftlparm.
sw66 TN StrataCom BPX 15 8.4 Aug. 27 1997 22:31 GMT
1 Enable [ Yes]
2 Normal Interval [ 150] (100msecs)
3 Fast Interval [ 50] (100msecs)
4 Low Threshold [ 50] (D)
5 High Threshold [ 90] (D)
6 Min Percent Chg, Mid 1 [ 10] (D)
7 Min Percent Chg, Mid 2 [ 6] (D)
8 Min Percent Chg, Mid 3 [ 3] (D)
9 Min Percent Chg, Upper [ 2] (D)
10 Background Updt Count [ 0] (D)
11 Update Algorithm [ 0] (D)
This Command: cnftlparm
Enter parameter index:
The cnftrkparm command sets specified trunk parameters for the following front cards:
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
dsptrkstathist, dsptrkstatcnf
| <trk number> | specifies the trunk to configure (can be a virtual trunk). |
| <parm index> | specifies the parameter to change. |
| <parm value> | specifies the value of the parameter. |
Use the cnftrkparm command to optimize a network for particular traffic mixes. This command configures any of the trunk-specific parameters associated with a trunk card. It applies to either a FastPacket trunk or an ATM trunk. For ATM trunks, cnftrkparm applies to both physical and virtual trunks. Spacer queues indicated for the CLP and EFCN thresholds pertain to AIT and BTM cards in an IPX node or IGX node, respectively.
This command can also reconfigure trunk queue depths to meet the CEPT requirement for a maximum end-to-end delay of 10 milliseconds. For this purpose, enter the following:
cnftrkparm <trunk number> <parameter index> <parameter value>
where: trunk number specifies the trunk.
parameter index is 2 (which corresponds to the NTS queue).
parameter value is 7 (which is the maximum allowable queue depth).
When the system receives this command and a trunk number, it displays the configurable parameters with an index number for each. The parameters vary with the trunk type, as the subsequent figures and tables show. Table 1-18, Table 1-19, and Table 1-20 list the parameters for trunks carrying FastPackets and ATM cells on different platforms as well as virtual trunks. Figure 1-30, Figure 1-31, Figure 1-32, and Figure 1-33 show the response when you specify a FastPacket line or trunk on a variety of platforms. A table follows one or two screen examples.
sw83 TN StrataCom IPX 16 8.4 Aug. 23 1997 15:58 PST PLN 13 Parameters: 1 Yel Alm-In/Out (D) [ 600/ 600] 18 Red Alm-In/Out (D) [ 2500/ 15000] 2 Rx Max Age - Voice (D) [ N/A] 19 Tx Max Age - Voice (D) [ 20] 3 Rx EFCN - BdataB (D) [ N/A] 20 Tx EFCN - BdataB (D) [ 30] 4 Gateway Efficiency (D) [ N/A] 5 EFCN - Rx Space (D) [ N/A] Tx Age Step2 (D) Tx Age Step (D) 6 Low CLP - Rx_Space (%) [ N/A] 21 BDataA [ 128] 23 BDataA [ 128] 7 High CLP - Rx_Space (%) [ N/A] 22 BDataB [ 128] 24 BDataB [ 128] Rx High CLP (%) Rx Low CLP (%) Tx High CLP (%) Tx Low CLP (%) 8 BDataA [ N/A] 10 BDataA [ N/A] 25 BDataA [ 100] 27 BDataA [ 100] 9 BDataB [ N/A] 11 BdataB [ N/A] 26 BDataB [ 75] 28 BDataB [ 25] Receive Queue Depth (D) Transmit Queue Depth (D) 12 Voice [ N/A] 15 BDataA [ N/A] 29 Voice [ 22] 32 BDataA [ 301] 13 Non TS [ N/A] 16 BDataB [ N/A] 30 Non TS [ 114] 33 BDataB [ 301] 14 TS [ N/A] 17 HighPri[ N/A] 31 TS [2616] 34 HighPri[ 100] Last Command: cnftrkparm 13 Next Command:
| Index | Parameter | Description |
|---|---|---|
| 1, 18 | Yel/Red Alarm In/Out | Specifies a time period relating to when a trunk goes into a red or yellow alarm and after it comes out of the alarm state. The applicable type of alarm here stems from a physical line problem rather than from a statistical error. The purpose of this parameter is to prevent the switch from rerouting the connections after a very brief problem or from prematurely informing switch software that the trunk is back in service (after a failure). The implementation is:
|
|
2, 19 | Rx/Tx Max. Age: - Voice | Specifies a multiplier for 125-microsecond increments for the maximum age of voice packets. For example, with the default of 20, the node discards voice packets older than 2.5 seconds.
Note that, if you increase the maximum age of a voice packet, the node increases the size of the Rx and Tx voice queues. |
| 3, 20 | Rx/Tx EFCN - BdataB | For packets or cells received from the trunk carrying ForeSight Frame Relay, the node sets the EFCN bit above this threshold. |
| 4 | Gateway Efficiency | Specifies an expected average number of FastPackets in each cell arriving from a trunk. The purpose if this parameter is to help switch software regulate bandwidth usage on the MUXBUS in an IPX node or the CELLBUS in an IGX node. The range is 1.0-3.0. |
| 5 | EFCN - Rx Space | Same as 3, 20 except that EFCN - Rx Space sets the threshold in the RX spacer queues in the AIT or BTM card. Rx space queues face towards the IPX or IGX node. |
| 6, 7 | Low-High CLP-Rx Space | Same as 8, 9 except this threshold is for setting CLP in receive spacer queues for data to send to the local node. |
| 8, 9 | Rx High CLP (Bdata A/BdataB) | Frame relay cells/packets received from trunk with CLP bit set above this high threshold will be dropped and will continue to be dropped until the low threshold is crossed. Separate queues for ForeSight and non-ForeSight data. Given in terms of % of queue depth. |
| 10, 11 | Rx Low CLP (Bdata A/BdataB) | Same as for 8, 9 except sets low threshold. |
| 25, 26 | Tx High CLP | Same as 8, 9 except this is threshold for setting CLP in transmit queues for data to be output to the next link. |
| 27, 28 | Tx Low CLP | Same as for 25, 26 except sets low threshold. |
| 12-17 | Receive Queue Depth (Voice, NTS, TS, BData A, BData B, High Pri.) | Reserves RAM in the trunk card for each of the receive queues in terms of the number of packets. |
| 29-34 | Transmit Queue Depth | Reserves RAM in the trunk card for each of the transmit queues in terms of the number of packets. |
pubsbpx1 TN StrataCom BPX 15 8.4 July 15 1997 09:37 GMT
TRK 1.1 Parameters
1 Q Depth - Voice [ 242] (Dec) 15 Q Depth - CBR [ 600] (Dec)
2 Q Depth - Non-TS [ 360] (Dec) 16 Q Depth - VBR [ 1000] (Dec)
3 Q Depth - TS [ 1000] (Dec) 17 Q Depth - ABR [ 9070] (Dec)
4 Q Depth - BData A [ 1000] (Dec) 18 Low CLP - CBR [ 100] (%)
5 Q Depth - BData B [ 8000] (Dec) 19 High CLP - CBR [ 100] (%)
6 Q Depth - High Pri [ 1000] (Dec) 20 Low CLP - VBR [ 100] (%)
7 Max Age - Voice [ 20] (Dec) 21 High CLP - VBR [ 100] (%)
8 Red Alm - I/O (Dec) [ 2500 / 15000] 22 Low CLP - ABR [ 25] (%)
9 Yel Alm - I/O (Dec) [ 2500 / 15000] 23 High CLP - ABR [ 75] (%)
10 Low CLP - BData A [ 100] (%) 24 EFCN - ABR [ 30] (Dec)
11 High CLP - BData A [ 100] (%) 25 SVC Queue Pool Size [ 144] (Dec)
12 Low CLP - BData B [ 25] (%)
13 High CLP - BData B [ 75] (%)
14 EFCN - BData B [ 30] (Dec)
This Command: cnftrkparm 1.1
Which parameter do you wish to change:
sw97 TRM StrataCom BPX 15 8.4 Apr. 30 1997 13:14 GMT
TRK 13.1 Parameters
Trunk Type: NNI
1 Q Depth - Voice [3000] (Dec) 15 Q Depth - CBR [ 1200] (Dec)
2 Q Depth - Non-TS [ 3000] (Dec) 16 Q Depth - VBR [ 10000] (Dec)
3 Q Depth - TS [ 1000] (Dec) 17 Q Depth - ABR [ 30000] (Dec)
4 Q Depth - BData A [ 20000] (Dec) 18 Low CLP - CBR [ 100] (%)
5 Q Depth - BData B [ 20000] (Dec) 19 High CLP - CBR [ 100] (%)
6 Q Depth - High Pri [ 1000] (Dec) 20 Low CLP - VBR [ 100] (%)
7 Max Age - Voice [ 20] (Dec) 21 High CLP - VBR [ 100] (%)
8 Red Alm - I/O (Dec) [ 2500 / 15000] 22 Low CLP - ABR [ 25] (%)
9 Yel Alm - I/O (Dec) [ 2500 / 15000] 23 High CLP - ABR [ 75] (%)
10 Low CLP - BData A [ 100] (%) 24 EFCN - ABR [ 30] (Dec)
11 High CLP - BData A [ 100] (%) 25 SVC Queue Pool Size [ 144] (Dec)
12 Low CLP - BData B [ 25] (%)
13 High CLP - BData B [ 75] (%)
14 EFCN - BData B [ 30] (Dec)
Last Command: cnftrkparm 13.1
Next Command:
| Index | Parameter | Description |
|---|---|---|
| 1 | Q Depth - Voice | Specifies the queue depth in cells for voice traffic. This parameter relates to item 7, Max Age - Voice: if you increase the value for Max Age - Voice, the node increases the size of the Voice Packet Queue because more voice packets can accumulate due to a greater age. |
| 2 | Q Depth - Non-TS | Specifies the queue depth in cells for non-time-stamped traffic. |
| 3 | Q Depth - TS | Specifies the queue depth in cells for time-stamped traffic. |
| 4 | Q Depth - BData A | Specifies the depth in cells for the bursty data A queue. |
| 5 | Q Depth - BData B | Specifies the depth in cells for the bursty data B queue. |
| 6 | Q Depth - High Pri | Specifies the queue depth in cells for high priority traffic |
| 7 | Max Age - Voice | Specifies a multiplier for 125-microsecond increments for the maximum age of voice packets. For example, with the default of 20, the node discards voice packets older than 2.5 seconds.
This parameter relates to item 1, Q Depth - Voice: if you increase the value for Max Age - Voice, the node increases the size of the Voice Packet Queue because more voice packets can accumulate due to a greater age. |
| 8 | Red Alm - I/O (Dec) | Specifies a time period relating to when a trunk goes into red alarm and after it comes out of the alarm state. The applicable type of alarm here stems from a physical line problem rather than from a statistical error. The purpose of this parameter is to prevent the switch from rerouting the connections after a very brief problem or from prematurely informing switch software that the trunk is back in service (after a failure). The implementation is:
|
|
9 | Yel Alm - I/O (Dec) | Specifies a time period relating to when a trunk goes into yellow alarm and after it comes out of the alarm state. The applicable type of alarm here stems from a physical line problem rather than from a statistical error. The purpose of this parameter is to prevent the switch from rerouting the connections after a very brief problem or from prematurely informing switch software that the trunk is back in service (after a failure). The implementation is:
|
|
10 | Low CLP - BData A | Specifies a percent of the Bursty Data A queue. When the number of cells in the queue falls below this percentage, the switch stops discarding cells with CLP=1. The default of 100% disables the function, which causes the switch to discard all cells with CLP=1. |
| 11 | High CLP - BData A | Specifies a percent of the Bursty Data A queue. When the number of cells in the queue reaches this percentage, the switch begins to discard cells with CLP=1. The default of 100% disables the function, which causes the switch to discard all cells with CLP=1 regardless of the cell count in the queue. |
| 12 | Low CLP - BData B | Specifies a percent of the Bursty Data B queue. When the number of cells in the queue falls below this percentage, the switch stops discarding cells with CLP=1. |
| 13 | High CLP - BData B | Specifies a percent of the Bursty Data B queue. When the number of cells in the queue reaches this percentage, the switch begins to discard cells with CLP=1. |
| 14 | EFCN - BData B | Specifies the number of cells in the Bursty Data B queue that causes the switch to send congestion notification to the destination node. The default is low in relation to the default queue depth so that notification begins to go out as soon as congestion begins. |
| 15 | Q Depth - CBR | Specifies the depth of the queue dedicated to CBR traffic. |
| 16 | Q Depth - VBR | Specifies the depth of the queue dedicated to VBR traffic. |
| 17 | Q Depth - ABR | Specifies the depth of the queue dedicated to ABR traffic. |
| 18 | Low CLP - CBR | Specifies a percent of the CBR queue. When the number of cells in the queue falls below this percentage, the node stops discarding cells with CLP=1. The default of 100% disables the function, which causes the switch to discard all cells with CLP=1 regardless of the cell count in the queue. The reason the default is 100% is that, with CBR, congestion is not an expected condition. |
| 19 | High CLP - CBR | Specifies a percent of the CBR queue. When the number of cells in the queue reaches this percentage, the node begins to discard cells with CLP=1. The default of 100% disables the function, which causes the switch to discard all cells with CLP=1 regardless of the cell count in the queue. The reason the default is 100% is that, with CBR, congestion is not an expected condition. |
| 20 | Low CLP - VBR | Specifies a percent of the VBR queue. When the number of cells in the queue falls below this percentage, the node stops discarding cells with CLP=1. The default of 100% disables the function, which causes the switch to discard all cells with CLP=1 regardless of the cell count in the queue. The reason the default is 100% is that, with VBR, congestion is not an expected condition. |
| 21 | High CLP - VBR | Specifies a percent of the VBR queue. When the number of cells in the queue reaches this percentage, the node begins to discard cells with CLP=1. The default of 100% disables the function, which causes the switch to discard all cells with CLP=1 regardless of the cell count in the queue. The reason the default is 100% is that, with VBR, congestion is not an expected condition. |
| 22 | Low CLP - ABR | Specifies a percent of the ABR queue. When the number of cells in the queue falls below this percentage, the node stops discarding cells with CLP=1. |
| 23 | High CLP - ABR | Specifies a percent of the ABR queue. When the number of cells in the queue reaches this percentage, the node begins to discard cells with CLP=1. |
| 24 | EFCN - ABR | Specifies the number of cells in the ABR queue that causes the switch to send congestion notification to the destination node. The default is low in relation to the default queue depth so that notification begins to go out as soon as congestion begins. |
| 25 | SVC Queue Pool Depth | Specifies the collective size of the queue depth for all SVC connections. |
sw97 TN StrataCom BPX 15 8.4 Aug. 9 1997 10:11 GMT TRK 1.1.1 Parameters 8 Red Alm - I/O (Dec) [ 2500 / 10000] 9 Yel Alm - I/O (Dec) [ 2500 / 10000] 15 Q Depth - CBR [ 2678] (Dec) 18 Low CLP - CBR [ 100] (%) 19 High CLP - CBR [ 100] (%) This Command: cnftrkparm 1.1.1 Which parameter do you wish to change:
| Index | Parameter | Description |
|---|---|---|
| 8 | Red Alm - I/O (Dec) | Specifies a time period relating to when a trunk goes into red alarm and after it comes out of the alarm state. The applicable type of alarm here stems from a physical line problem rather than from a statistical error. The purpose of this parameter is to prevent the switch from rerouting the connections after a very brief problem or from prematurely informing switch software that the trunk is back in service (after a failure). The implementation is:
|
|
9 | Yel Alm - I/O (Dec) | Specifies a time period relating to when a trunk goes into yellow alarm and after it comes out of the alarm state. The applicable type of alarm here stems from a physical line problem rather than from a statistical error. The purpose of this parameter is to prevent the switch from rerouting the connections after a very brief problem or from prematurely informing switch software that the trunk is back in service (after a failure). The implementation is:
|
|
18 | Low CLP - CBR | Specifies a percent of the CBR queue. When the number of cells in the queue falls below this percentage, the node stops discarding cells with CLP=1. The default of 100% disables the function, which causes the switch to discard all cells with CLP=1 regardless of the cell count in the queue. The reason the default is 100% is that, with CBR, congestion is not an expected condition. |
| 19 | High CLP - CBR | Specifies a percent of the CBR queue. When the number of cells in the queue reaches this percentage, the node begins to discard cells with CLP=1. The default of 100% disables the function, which causes the switch to discard all cells with CLP=1 regardless of the cell count in the queue. The reason the default is 100% is that, with CBR, congestion is not an expected condition. |
| 19 | High CLP | Specifies a percent of the transmit/receive CBR queue depth. When a transmit/receive threshold is exceeded, the node discards cells with CLP=1 in the connection until the VC queue level falls below the depth specified by Low CLP. |
The cnftrkstats command configures collection of statistics for a selected trunk.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
dsptrkstatcnf, dsptrkstathist
| <line> | specifies the trunk to configure. |
| <stat> | specifies the type of statistic to enable/disable. |
| <interval> | specifies the time interval of each sample (1-255 minutes). |
| <e|d> | enables/disables a statistic. 'E' to enable; 'D' to disable. |
| [samples] | specifies the number of samples to collect (1-255). |
| [size] | specifies the number of bytes per data sample (1, 2 or 4). |
| [peaks] | enables/disables collection of ten second peaks. 'Y' enables; 'N' disables. |
The cnftrkstats command is primarily a debug command. It configures the collection of statistics for a physical or virtual trunk. After displaying all statistic types for the trunk, the system prompts for "statistic type." Enter the index number associated with the statistic.
Not all types of statistics are available for all lines. Unavailable selections appear in half-tone. Table 1-21 lists the types of statistics that are configurable for FastPacket T1 trunks and ATM T3 trunks. The subsequent figures show the screens associated with T1 packet trunks and T3 ATM trunks.
| Categories of Statistics Types | Categories of Statistics Types |
|---|---|
| Line faults | Line errors and errored seconds |
| Frame Slips and Loss | Path errors |
| Transmit packets dropped | Cell framing errors |
| Packets transmitted for various packet types | EFCN packets transmitted to bus |
| Packets dropped for various packet types | Queue Service Engine (QSE) cells transmitted |
| Bursty data CLP packets and cells dropped | Spacer packets transmitted and dropped for each of the 16 queues |
| Errored seconds | The number of seconds in which errors occurred. |
Figure 1-34 is the only screen for T1 trunks.
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 14:42 PST
Line Statistic Types 1) Bipolar Violations 18) Voice Packets Transmitted 3) Out of Frames 19) TS Packets Transmitted 4) Losses of Signal 20) NTS Packets Transmitted 5) Frames Bit Errors 21) CC Packets Transmitted 6) CRC Errors 22) BDA Packets Transmitted 9) Packet Out of Frames 23) BDB Packets Transmitted 10) Packet CRC Errors 24) Total Packets Transmitted 12) Tx Voice Packets Dropped 25) BDA CLP Packets Dropped 13) Tx TS Packets Dropped 26) BDB CLP Packets Dropped 14) Tx NTS Packets Dropped 27) BDA EFCN Pkts Transmitted 15) Tx CC Packets Dropped 28) BDB EFCN Pkts Transmitted 16) Tx BDA Packets Dropped 149) Bdata A CLP Packets Tx to Line 17) Tx BDB Packets Dropped 150) Bdata B CLP Packets Tx to Line Last Command: cnftrkstats 13 Next Command:
The following screens, shown in Figure 1-35 through Figure 1-41, pertain to an ATM trunk (AIT card) on an IPX node. Other trunk types and cards have other parameters. To see the list of these, enter the command and continue from page to page without entering an index number.
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 14:45 PST Line Statistic Types 3) Out of Frames 22) BDA Packets Transmitted 4) Losses of Signal 23) BDB Packets Transmitted 10) Packet CRC Errors 24) Total Packets Transmitted 12) Tx Voice Packets Dropped 25) BDA CLP Packets Dropped 13) Tx TS Packets Dropped 26) BDB CLP Packets Dropped 14) Tx NTS Packets Dropped 27) BDA EFCN Pkts Transmitted 15) Tx CC Packets Dropped 28) BDB EFCN Pkts Transmitted 16) Tx BDA Packets Dropped 29) Line Code Violations 17) Tx BDB Packets Dropped 30) Line Errored Seconds 18) Voice Packets Transmitted 31) Line Severely Err Secs 19) TS Packets Transmitted 32) Line Parity Errors 20) NTS Packets Transmitted 33) Errored Seconds - Line 21) CC Packets Transmitted 34) Severely Err Secs - Line This Command: cnftrkstats 11 Continue?
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 14:46 PST Line Statistic Types 35) Path Parity Errors 48) Tx Voice Cells Drpd 36) Errored Secs - Path 49) Tx TimeStamped Cells Drpd 37) Severely Err Secs - Path 50) Tx NTS Cells Dropped 38) Severely Err Frame Secs 51) Tx Hi-Pri Cells Drpd 39) AIS Signal Seconds 52) Tx BData A Cells Drpd 40) Unavail. Seconds 53) Tx BData B Cells Drpd 41) BIP-8 Code Violations 54) Voice Cells Tx to line 42) Cell Framing Errored Seconds 55) TimeStamped Cells Tx to ln 43) Cell Framing Sev. Err Secs. 56) NTS Cells Tx to line 44) Cell Framing Sec. Err Frame Secs 57) Hi-Pri Cells Tx to line 45) Cell Framing Unavail. Secs. 58) BData A Cells Tx to line 46) ATM Cell Header HEC Errs 59) BData B Cells Tx to line 47) Pkts. Rx from Muxbus 60) Half Full cells Tx to ln This Command: cnftrkstats 11 Continue?
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 14:47 PST Line Statistic Types 61) Full cells Tx to ln 74) Rx Hi-pri Pkts Dropped 62) Total Cells Tx to line 75) Rx BDA Pkts Dropped 63) Tx Bdata A CLP Cells Drpd 76) Rx BDB Pkts Dropped 64) Tx Bdata B CLP Cells Drpd 77) Voice pkts Tx to Muxbus 65) Bdata A EFCN Cells Tx ln 78) TS pkts Tx to Muxbus 66) Bdata B EFCN Cells Tx ln 79) NTS pkts Tx to Muxbus 67) Half Full Cells Rx from ln 80) Hi-pri pkts Tx to Muxbus 68) Full Cells Rx from line 81) Bdata A pkts Tx to Muxbus 69) Total Cells Rx from line 82) Bdata B pkts Tx to Muxbus 70) Total pkts Rx from line 83) Rx Bdata A CLP pkts drpd 71) Rx Voice Pkts Dropped 84) Rx Bdata B CLP pkts drpd 72) Rx TS Pkts Dropped 85) Bdata A EFCN Pkts Tx muxbus 73) Rx NTS Pkts Dropped 86) Bdata B EFCN Pkts Tx muxbus This Command: cnftrkstats 11 Continue?
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 14:48 PST Line Statistic Types 87) Total Pkts Tx to muxbus 100) Rx Spacer 2 Pkts dropped 88) Rx voice cells drpd 101) Rx Spacer 3 Pkts dropped 89) Rx TimeStamped Cells drpd 102) Rx Spacer 4 Pkts dropped 90) Rx NTS Cells dropped 103) Rx Spacer 5 Pkts dropped 91) Rx Hi-pri Cells dropped 104) Rx Spacer 6 Pkts dropped 92) Rx Bdata A Cells dropped 105) Rx Spacer 7 Pkts dropped 93) Rx Bdata B Cells dropped 106) Rx Spacer 8 Pkts dropped 94) Rx Bdata A CLP cells drpd 107) Rx Spacer 9 Pkts dropped 95) Rx Bdata B CLP cells drpd 108) Rx Spacer 10 Pkts dropped 96) Rx Spacer CLP Pkts drpd 109) Rx Spacer 11 Pkts dropped 97) Spacer EFCN Pkts Tx to Muxbus 110) Rx Spacer 12 Pkts dropped 98) Frame Sync Errors 111) Rx Spacer 13 Pkts dropped 99) Rx Spacer 1 Pkts dropped 112) Rx Spacer 14 Pkts dropped This Command: cnftrkstats 11
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 14:49 PST Line Statistic Types 113) Rx Spacer 15 Pkts dropped 126) Spacer 10 Pkts Tx to Muxbus 114) Rx Spacer 16 Pkts dropped 127) Spacer 11 Pkts Tx to Muxbus 115) Rx Spacer Pkts drpd 128) Spacer 12 Pkts Tx to Muxbus 116) Spacer 0 Pkts Tx to Muxbus 129) Spacer 13 Pkts Tx to Muxbus 117) Spacer 1 Pkts Tx to Muxbus 130) Spacer 14 Pkts Tx to Muxbus 118) Spacer 2 Pkts Tx to Muxbus 131) Spacer 15 Pkts Tx to Muxbus 119) Spacer 3 Pkts Tx to Muxbus 132) Spacer 16 Pkts Tx to Muxbus 120) Spacer 4 Pkts Tx to Muxbus 133) Rx Voice QSE Cells Tx 121) Spacer 5 Pkts Tx to Muxbus 134) Rx Time Stamped QSE Cells Tx 122) Spacer 6 Pkts Tx to Muxbus 135) Rx NTS QSE Cells Tx 123) Spacer 7 Pkts Tx to Muxbus 136) Rx Hi Priority QSE Cells Tx 124) Spacer 8 Pkts Tx to Muxbus 137) Rx BData A QSE Cells Tx 125) Spacer 9 Pkts Tx to Muxbus 138) Rx Bdata B QSE Cells Tx This Command: cnftrkstats 11
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 15:02 PST Line Statistic Types 139) Rx BData A EFCN QSE Cells Tx 152) Cell Framing Yel Transitions 140) Rx BData B EFCN QSE Cells Tx 153) AIS Transition Count 141) FEBE Counts 161) CGW Packets Rx From IPX Net 142) FERR Counts (M or F bit) 162) CGW Cells Tx to Line 143) Cell Framing FEBE Err Secs 163) CGW Frms Relayed to Line 144) Cell Framing FEBE Sev. Err. Secs. 164) CGW Aborted Frames Tx to Line 145) Cell Framing FEBE Counts 165) CGW Dscd Pkts From Abted Frms 146) Cell Framing FE Counts 166) CGW 0-Lngth Frms Rx from Line 147) ATM CRC Errored Seconds 167) CGW Packets Tx to IPX Net 148) ATM CRC Severely Err. Secs. 168) CGW Cells Rx from Line 149) Bdata A CLP Packets Tx to Line 169) CGW Frms Relayed from Line 150) Bdata B CLP Packets Tx to Line 170) CGW Aborted Frms Rx From Line 151) Yellow Alarm Transition Count 171) CGW Dscd Cells From Abted Frms This Command: cnftrkstats 11
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 14:51 PST Line Statistic Types 172) CGW Bd CRC32 Frms Rx from Line 185) OAM Valid OAM Cells Rx 173) CGW Bd Lngth Frms Rx from Line 186) OAM Loopback Cells Rx 174) CGW Bd CRC16 Frms Rx from IPX 187) OAM AIS Cells Rx 175) CGW Bd Length Frms Rx from IPX 188) OAM FERF Cells Rx 176) CGW 0-Length Frms Rx from IPX 189) OAM RTD Cells Rx 177) OAM Valid OAM Cells Tx 190) OAM RA Cells Rx 178) OAM Loopback Cells Tx 191) OAM Invalid OAM Cells Rx 179) OAM AIS Cells Tx 192) OAM CC Cells Rx 180) OAM FERF Cells Tx 181) OAM RTD Cells Tx 182) OAM RA Cells Tx 183) OAM Invalid Supv Packets Rx 184) OAM CC Cells Tx This Command: cnftrkstats 11
The cnftstparm command sets parameters for the internal diagnostic self tests that can be performed for each card type in the node.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
cnfdiagparm, dspcderrs, prtcderrs, tststats
| <tp> | Specifies the card type. |
| <freq> | Specifies the time between the finish of one test and the start of the next (in seconds; the default is card-dependent). 1 sec-65535secs |
| <s_e> | Enables/disables the card self test. 'E' to enable; 'D' to disable. |
| <s_inc> | Specifies the threshold counter increment for self test failures. Counter for each card-type: each failure increments. Default 100. |
| <s_thr> | Specifies the failure threshold for self tests. Default 300. |
| <s_to> | Specifies time to wait for a self test response (in seconds). The length of time is card-dependent |
| <b_e> | Enables/disables the card background test. 'E' to enable; 'D' to disable. Which tests are available tests are card depenedent. |
| <b_inc> | Specifies the threshold counter increment for background test failures. |
| <b_thr> | Specifies the failure threshold for background tests. |
This command sets internal diagnostic, self-test parameters. Upon command entry, the system displays a two-page screen illustrating each of the various card types equipped in the node along with their self test parameters. Each card has two tests: a diagnostic self-test and a background test. The self-test affects the normal operation of the card. The background test can execute while the card is carrying traffic.
The following is a list of the configurable test parameters for each card type:
After cnftstparm is entered, Figure 1-42 shows the first page of the display.
sw45 TN StrataCom BPX 15 8.4 Aug. 27 1997 16:04 PDT
Card Test - - - - - - Self Test - - - - - - - - - Background Test - - -
Type Freq Enable Inc Thresh Timeout Enable Inc Thresh
---- ----- -------- ------- ------- ------- -------- ------- -------
BCC 90 Enabled 100 300 300 N/A 100 300
ASM 300 Disabled 100 300 60 N/A 100 300
BNI-T3 300 Enabled 100 300 150 N/A 100 300
BNI-E3 300 Enabled 100 300 150 N/A 100 300
ASI-E3 900 Enabled 100 300 800 Enabled 100 300
ASI-T3 900 Enabled 100 300 800 Enabled 100 300
ASI-155 900 Enabled 100 300 800 Enabled 100 300
BNI-155 300 Enabled 100 300 150 N/A 100 300
BXM 2000 Disabled 100 300 1800 Enabled 100 300
Last Command: cnftstparm
Next Command:
To see the second screen, enter "y" at the Continue prompt.
The cnfuiparm command sets various control terminal user interface parameters.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
cnfnodeparm
| <parameter number> | specifies the index number of the parameter to set. (See Table 1-22.) |
| <value> | specifies the new parameter value to enter. |
This command sets user interface parameters for the control terminal. These parameters can be changed at the local node only. It may be necessary to change these parameters in special circumstances, e.g. when a continuous screen is to be observed for a long time or modem password protection makes logging in a difficult procedure. Table 1-22 lists the user interface parameters. Figure 1-43 illustrates the associated display.
| No. | Parameter | Description | Default * |
|---|---|---|---|
| 1 | Logout Time | Idle time before a local user is logged out (0 = never). | 20 min. |
| 2 | VT Logout Time | Idle time before a Virtual Terminal user is logged out. | 4 min. |
| 3 | Prompt Time | Idle time before a parameter prompt times out. | 2 min. |
| 4 | Command Time | Idle time before a continuous command times out. | 3 min. |
| 5 | UID Privilege Level | Privilege level of User ID allowed to use control terminal. Default is 6, the lowest level user. | 6 |
| 6 | Input Char Echo | If enabled, characters are echoed as they are typed. | enabled |
| 7 | Screen Update Time | The time between screen updates. | 2 secs. |
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 17:01 PST 1. Logout Time ........... No Timeout 2. VT Logout Time ........ 4 minutes 3. Prompt Time ........... 60 seconds 4. Command Time .......... 3 minutes 5. UID Privilege Level ... 6 6. Input Character Echo .. Enabled 7. Screen Update Time .... 2 seconds This Command: cnfuiparm Enter parameter index:
The cnfvchparm command modifies CDP or CVM voice channel parameters.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX
cnfcdpparm, dspchan
| channel(s) | Specifies the voice channel number(s) to configure. |
| parameters | Specifies values for the voice parameters (Table 1-23 lists parameters). |
The cnfvchparm command specifies voice card parameters for:
Table 1-23 lists the voice parameters you can specify with cnfvchparm. Table 1-24 lists some calculated examples for a sample delay for VAD and non-VAD connections.
Different versions of firmware for the CDP and CVM present different ways of specifying the level of background noise you can select to cover awkward periods of silence at the ends of voice connections. For cards with Model A firmware, you specify the actual level in dBm (deciBels) or dBrnC0. For Model A cards, you can specify the noise levels with a granularity of 0.1 dBm or dBrnC0. For cards with Model B firmware, you enter a number that maps to a noise level. Table 1-25 lists the numbers that correspond to the levels of injected background noise for Model B firmware.
The screen displays in Example 1 and Example 2 illustrate cnfvchparm applied to a Model A CDP and a Model B CDP, respectively. The display for Model A cards shows the deciBel level of the injected noise. The display for the Model B shows the number that corresponds to a deciBel (or dBrnC0) level of background noise.
After you enter cnfvchparm, the system displays "Enter channel(s)." After you enter the parameters, the system requests confirmation by displaying "Reconfigure active CDP channels? (y/n)."
Without the cnfvchparm command, the other ways to re-configure channels are:
| Parameter | Description | Default * |
|---|---|---|
| Sample delay for VAD connections | Adds processing to speech information to prevent front-end clipping due to speech detector latency. Incremental units are 125 msecs. See Table 1-24 for samples. | A8 (H) |
| Sample delay for non-VAD connections | Same for non-VAD circuits. | 01 (H) |
| Background Noise | Sets the level of background noise that the far-end voice card adds to the connection while it is receiving no voice packets. For Model A firmware, you specify the levels in actual decibels in 0.1 dB increments. For Model B firmware, see Table 1-27 for levels. | 2 (H) |
| High Pass Filter mode | Enables/disables high-pass filter to assist in VAD and modem detect. | enabled |
| Floating Priority mode | When enabled, sets higher priority for modem detection on "c" and "v" channels. Effectively changes the trunk queue for the channel. | enabled |
| V.25 modem detect mode | Enables/disables V.25 modem-detect mode. The default is enabled with "detect-64K," which specifies that a 2100 Hz tone indicates the presence of V.25-type modem. The options with V.25 modem detect are "disable," "32" for 32K upgrade, and "64" for 64K upgrade. Enter "32" for fax transmission at 32 Kbps FAX Optimized ADPCM. Use the default "64" for fax transmission at 64 kbps PCM. | enabled |
| 32K | Automatically upgrade line to 32 Kbps ADPCM when a 32K modem is detected. | disabled |
| 64K | Automatically upgrade line to 64 Kbps clear channel PCM when a high speed modem is detected. | enabled |
| Delay for VAD and Non-VAD | Delay |
|---|---|
| 01 | 0.125 msec. |
| 50 | 10 msec. |
| A8 | 21 msec. |
| Parameter 3 | Injected Noise Level |
|---|---|
| 00 | Dynamically set noise level to match the noise detected at the other end. Requires Model B firmware on the CDP or CVM. |
| 0 | 0 dBrnC0 or -90 dBm |
| 1 | 18 dBrnC0 or -70 dBm |
| 2 | 21 dBrnC0 or -67 dBm |
| 3 | 23 dBrnC0 or -65 dBm |
| 4 | 25 dBrnC0 or -63 dBm |
| 5 | 27 dBrnC0 or -61 dBm |
| 6 | 30 dBrnC0 or -58 dBm |
| 7 | 49 dBrnC0 or -39 dBm |
sw110 TN StrataCom IGX 16 8.4 Jan. 6 1997 17:43 PDT
CDP Models All None All
UVM Models All None All
Sample Delay Bkgnd Echo Suppression V.25 Xmit
From 14.1 VAD Non-VAD Noise HPF Float Function Loss Detect Delay
14.1-15 A8 01 67 ON ON ON ON 64K 5
14.17-24 A8 01 67 ON ON ON ON 64K 5
This Command: cnfvchparm 14.1-6 A8 1 67 e e e e
V.25 Modem detect, 'd' - disable, '32' - 32K upgrade, '64' - 64K upgrade:
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 17:01 PST CDP Models All None All Sample Delay Bkgnd Echo Suppression V.25 Xmit From 11.1 VAD Non-VAD Noise HPF Float Function Loss Detect Delay 11.1-15 A8 01 2 ON ON ON ON ON 5 11.17-31 A8 01 2 ON ON ON ON ON 5 This Command: cnfvchparm Next Command:
The cpyfpmap command copies the FastPAD map table from one FastPAD port to another.
Jobs: No Log: No Lock: Yes Node Type: IPX, IGX
cnffpmap
| <source slot.port> | specifies the FTC port to copy from. |
| <nodename> | specifies the nodename. |
| <destination slot.port> | specifies the FTC port to copy to. |
This command copies a FastPAD map table from one FastPAD port to another FastPAD port. When you enter this command, the system responds as shown in Figure 1-44.
cc7 VT StrataCom IPX 32 8.4 Jan. 30 1997 10:05 PST Last Command: 31.2 cc5 31.1 Next Command:
The dchst command displays CDP or CVM card parameters.
Jobs: No Log: No Lock: Yes Node Type: IPX, IGX
cnfcdpparm
| <channel(s)> | specifies the voice channel number(s) to configure. |
| <interval> | specifies the refresh time for the data (1-60 sec.) |
This command displays state information for a CDP or CVM channel used for a specific connection. The interval parameter specifies the refresh time for the data. It defaults to 5 seconds. The Transmit and Receive dBm0 for both CDP or CVM indicate the input (towards the circuit line) and output power (from the circuit line) levels for the channel. Modem state indicates whether modem-detect is on or off.
Table 1-26 lists the parameters for the CDP or CVM card. Figure 1-45 illustrates the system display for a CDP or CVM.
| Register | Byte | Parameter | Description |
|---|---|---|---|
| 0 | high low | zcr total signal state mem | Zero Crossing Total Signal State Memory |
| 1 | high low | hpf z1 hi - hi hpf z1 hi - lo | High-Pass Filter High-Pass Filter |
| 2 | high low | sam - hi sam - lo | Encoded Voice Sample Encoded Voice Sample |
| 3 | high low | vad state-hi vad state-lo | Voice Activity Detector state Voice Activity Detector state |
| 4 | high low | sil cnt mad signal state | Silent Count Modem Activity Detector Signal State |
| 5 | high low | mad wnd cnt mad fail cnt | Modem Activity Detector Wnd. Count Modem Activity Detector Fail Count |
| 6 | high low | mad state-hi mad state-lo | Modem Activity Detector state Modem Activity Detector state |
alpha TRM SuperUser Rev: 8.4 Jan. 14 1997 16:30 PST CDP state display for channel 11.1 Snapshot Transmit dBm0: Receive dBm0: Register 0 = Register 1 = Register 2 = Register 3 = Register 4 = Register 5 = Register 6 = Last Command: dchst 11.1 Next Command:
The diagbus command is used to diagnose a failed IPX MUXBUS.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
none
This command runs detailed diagnostics to isolate muxbus problems to a failed card or bus. It is used when a minor alarm is indicated and displaying the alarm (dspalms) screen indicates the message "bus needs diagnosis."
This command can only be run locally with a terminal connected directly to the CONTROL port or remotely from a modem connection. It can not be executed through a VT (virtual terminal) command or when the node's CONTROL port is configured for StrataView mode.
![]() | Caution This command may cause a major disruption in service on all lines and connections and should only be run at a time when this can be tolerated. |
Performing this test can result in a major disruption in the operation of the node. It should not be performed except as a last resort. To fully isolate the failure may require manual removal of cards, including controller cards etc. For this reason, the command may not be executed over a Virtual Terminal connection.
If the test is successful, and no problems found, the system displays:
Both buses are OK
Otherwise, the system displays various messages to the operator for additional steps to perform in isolating the problem. These messages depend on the results of the diagnostics testing.
The drtop command displays the routing table from the local node to each connected remote node.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
dsptrkcons
This command displays the routing table from the local node to each remote node to which it is connected. It shows how NPC/B.C. traffic is routed to other nodes in the network. Use drtop command to find which trunks are used to send control cells/packets to other nodes.
The display includes remote node name, number of hops to the remote node, the trunk(s) used, and number of satellite hops if any, and the number of unused DS0s (open space) if any on the route. Figure 1-46 illustrates the display.
pubsipx2 VT StrataCom IPX 32 8.4 Feb. 2 1997 02:27 GMT Node Number Node Name Hops To Via Trk SAT Hops No HP Hops Open Space 1 D1.pubsbpx1 2 6 0 0 3 2 D1.pubsigx1 3 6 0 0 3 3 D1.pubsipx2 0 0 0 0 0 5 D1.pubsipx1 1 6 0 0 24 7 D1.pubsipx3 2 6 0 0 24 Last Command: drtop Next Command:
The dspasich command displays the ATM channel routing entries for an ASI card.
Jobs: No Log: No Lock: Yes Node Type: BPX
None
| <line> | specifies the line in the format slot.port. |
| <channel> | specifies the channel in the format vpi.vci. |
This command displays the routing entries for an ASI card shown in Figure 1-47.
pubsbpx1 VT StrataCom BPX 15 8.4 May 24 1997 21:09 GMT ASI Channel Configuration Query & Display Slot.port.lcn:5.1.1 Status: Added BF hdr: 4145 9002 8012 0501 8640 0000 2DEB [00] BF tp: 4 [11] VCI: 00000064 [22] UPC CDV: 0 [33] FST up: 0 [01] Pri SDA: 5 [12] Con tp: VC [23] UPC CIR: 500 [34] FST dn: 0 [02] Dst Prt: 1 [13] Rmt tp: ASI [24] UPC CBS: 1000 [35] FST fdn: 0 [03] Dst lcn: 2 [14] Srv tp: VBR [25] UPC IBS: 0 [36] FST rmx: 0 [04] BCF tp: 0 [15] Gen AIS: N [26] UPC MFS: 200 [37] Q max:64000 [05] Qbin#: 12 [16] Mcst: 0 [27] CLP enb: Y [38] EFCI: 100 [06] BF VPI: 64 [17] Mc grp: 1 [28] FST enb: N [39] CLP hi: 100 [07] BF VCI: 0 [18] & msk: 0000000F [29] FST MIR: 500 [40] CLP lo: 100 [08] Pl Cls: 0 [19] | msk: 06400640 [30] FST PIR: 500 [41] BCM: N [09] Rmt lp: N [20] Prt QBN: 2 [31] FST QIR: 500 [42] Inhibit:N [10] VPI: 00000064 [21] UPC GCR: 0 [32] QIR TO: 0 [43] UPC enb:Y Last Command: dspasich 5.1 1 N Next Command:
Displays the available MUXBUS bandwidth. The display is not updated and is referred to as a snapshot. The command lists the dedicated and pooled bandwidth units as well as the status of the available MUXBUS.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
cnfbus
This command displays the available MUXBUS bandwidth. The display is not updated and is referred to as a snapshot. The command lists the dedicated and pooled bandwidth units as well as the status of the available MUXBUS.
pubsipx2 VT StrataCom IPX 32 8.4 Feb. 2 1997 02:33 GMT
Bus Info
Available MUXBUS bandwidth (snapshot)
Dedicated Pooled Units
--------- ------ -----
0 19 8000 pkts/sec
0 152 1000 pkts/sec
0 456 ds0 circuits
Bus Status
-----------
Bus A: Active - OK
Bus B: Standby - OK
Last Command: dspbuses
The dspcardstats command displays the collected Monarch card statistics for the selected node slot.
Jobs: Yes Log: Yes Lock: Yes Node Type: BPX
cnfslotstats
| <slot number> | specifies the shelf and slot. |
This command displays all active BPX node Monarch card statistics.
sw59 TN StrataCom BPX 15 8.4.0 Date/Time Not Set
ASI-T3 12 Status: Clear - Slot OK Clrd: Date/Time Not Set
Type Count ETS Status Type
utopia-2 discard count 0 0
utopia-2 mislign count 0 0
atm fr. pyld parity err 0 0
bfr hdr parity err 0 0
null bfrm header err 0 0
brame hoq req t/o 0 0
poll bus parity err 0 0
bfr queue parity err 0 0
bfr bip16 parity err 0 0
mc addr tbl parity err 0 0
eap arfd pndg err 0 0
This Command: dspcardstats 12
Continue?
The dspcderrs command displays detailed card failure information resulting from card diagnostics testing at the local node.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
clrcderrs, prtcderrs
| [<slot>] | specifies the shelf slot in the local node. |
This command displays a history of card failures associated with a specified slot. If no argument is specified, a summary is displayed, indicating which slots have failures recorded against them. The command displays the results of the self tests and background tests as well as the total hardware errors.
To clear the card error counters, use the clrcderrs command. To obtain a hard copy of the report, use the prtcderrs command. Figure 1-50 illustrates the command display.
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 17:56 PST AIT in Slot 11 : 176767 Rev AEF Failures Cleared: Jan. 19 1997 11:25:29 PST ----------------------------------- Records Cleared: Jan. 20 1997 13:14:03 PST Self Test Threshold Counter: 0 Threshold Limit: 300 Total Pass: 0 Total Fail: 0 Total Abort: 0 First Pass: Last Pass: First Fail: Last Fail: Hardware Error Total Events: 0 Threshold Counter: 0 First Event: Last Event: Last Command: dspcderrs 11 Next Command:
The dspcftst command displays the test pattern used for the communications fail test.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
cnfcftst
This command displays the test pattern used to test the controller communication path to a node that does not respond to normal controller traffic. The test pattern defaults to an alternating 8-byte sequence of 00 and FF. Refer to cnfcftst command for other patterns and how to reconfigure this pattern. Figure 1-51 illustrates the command display.
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 17:57 PST
Comm Fail Test Pattern.
Byte 0: FF Byte 12: 00 Byte 24: FF Byte 36: 00 Byte 48: FF
Byte 1: FF Byte 13: 00 Byte 25: FF Byte 37: 00 Byte 49: FF
Byte 2: FF Byte 14: 00 Byte 26: FF Byte 38: 00 Byte 50: FF
Byte 3: FF Byte 15: 00 Byte 27: FF Byte 39: 00 Byte 51: FF
Byte 4: 00 Byte 16: FF Byte 28: 00 Byte 40: FF Byte 52: 00
Byte 5: 00 Byte 17: FF Byte 29: 00 Byte 41: FF Byte 53: 00
Byte 6: 00 Byte 18: FF Byte 30: 00 Byte 42: FF Byte 54: 00
Byte 7: 00 Byte 19: FF Byte 31: 00 Byte 43: FF Byte 55: 00
Byte 8: FF Byte 20: 00 Byte 32: FF Byte 44: 00 Byte 56: FF
Byte 9: FF Byte 21: 00 Byte 33: FF Byte 45: 00 Byte 57: FF
Byte 10: FF Byte 22: 00 Byte 34: FF Byte 46: 00 Byte 58: FF
Byte 11: FF Byte 23: 00 Byte 35: FF Byte 47: 00 Byte 59: FF
Last Command: dspcftst
Next Command:
The dspchan command displays the configuration of various IPX or IGX voice channels.
Jobs: No Log: No Lock: No Node Type: IPX, IGX
cnfcdpparm
| <channel> | specifies the voice channel connection to display. |
This command displays the configuration of IPX or IGX voice channels. It is primarily a debug command and allows inspection of the data structure defining a channel. Parameters for voice and signalling processing on a CDP or CVM voice channel are displayed by this command. Table 1-27 lists the parameters. Many of these parameters are also displayed elsewhere. Figure 1-52 illustrates the command display.
| Parameter | Parameter | Parameter | Parameter |
|---|---|---|---|
| VC Index | Dial Type | TX Sig | iec convergence |
| In Loss | TX A-D bit | RX Sig | Hi Pass F |
| Out Loss | RX A-D bit | Clr Chn | es loss |
| Chan Type | Signalling | Sig Rate | Fmodem |
| Sig. Intg | Echo supr | PLY MSBhx | ADV |
| Xmt. dlay | Wink Puls | PLY LSBhx | Cond ID |
| Smpl dlay | TX A-D Qual | In use | iec erl lvl |
| Bk noise | RX A-D Qual | DPU | iec Hregs. |
| DSI smple | TX Code | iec cancel | iec tone dsbl |
| Chan Util | RX Code | iec nlp | adpcm flag |
| Onhk A-D |
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 18:06 PST Channel Data Base for CDP card 7 chan. 000000 at address 30BF29EC VC Index -1 Onhk C 4 In Loss 0 Onhk D 4 Out Loss 0 Dial Type 0 Chan Type 1 TX A bit 1 Sig. Intg 96 TX B bit 1 Xmt. dlay 5 TX C bit 0 Smpl dlay 1 TX D bit 1 Bk noise 67 RX A bit 1 DSI smple 168 RX B bit 1 Chan Util 40 RX C bit 0 Onhk A 3 RX D bit 1 Onhk B 3 Signalling TSP MODE This Command: dspchan 7.1 Continue?
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 18:07 PST Channel Data Base for CDP card 7 chan. 000000 at address 30BF29EC Echo supr 1 TX A Qual 3 Hi Pass F 1 TX B Qual 3 Float 1 TX C Qual 3 es loss 1 TX D Qual 3 Fmodem 64 RX A Qual 3 ADV 1 RX B Qual 3 Cond ID 0 RX C Qual 3 Wink Puls 20 RX D Qual 3 END OF UNI CNFG This Command: dspchan 7.1 Continue?
sw83 TN StrataCom IPX 16 8.4. Feb. 1 1997 18:07 PST Channel Data Base for CDP card 7 chan. 000000 at address 30BF29EC TX CODE 3 iec cancel 0 RX CODE 3 iec nlp 1 TX SIG 0 iec converg. 1 RX SIG 0 iec erl lvl 1 CLR CHN 0 iec Hregs. 1 SIG RATE 0 iec tone dsbl 1 PLY MSBhx 1 adpcm flag 0 PLY LSBhx 90 In use 0 DPU - Last Command: dspchan 7.1 Next Command:
The dspchstatcnf command displays the configuration of enabled statistics for a channel.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
cnfchstats, dspchstathist
| <channel> | specifies the channel for whose statistics are to be listed. |
The dspchstatcnf command displays the enabled interval statistics for a channel. It is intended to help debug problems with statistics gathering. The command output is a list of the connection statistics as set by the cnfchstats command, by StrataView Plus, or by IPX or IGX features. Figure 1-53 illustrates a typical example.
The Owner column identifies who or what set the statistic. If the Owner column shows "Automatic," the node's features set the statistic. If the node name appears under Owner, StrataView Plus set the statistic. If the user name appears under Owner, the cnfchstats command executed from the command line interface set the statistic.
pubsbpx1 VT StrataCom BPX 15 8.4 May 24 1997 23:13 GMT
Statistics Enabled on Channel 5.1.100.100
Statistic Samples Interval Size Peaks Owner
------------------------------------ ------- -------- ---- ----- ----------
41) AAL5 Cells Discarded for VCQ Full 1 30 4 NONE TFTP
42) Average VCq Depth in Cells 1 30 4 NONE TFTP
43) Cells lost due to Rsrc Overflow 1 30 4 NONE TFTP
44) Cells discarded for SBIN full 1 30 4 NONE TFTP
45) Cells Transmitted with EFCI(Port) 1 30 4 NONE TFTP
46) Cells Transmitted(Port) 1 30 4 NONE TFTP
47) Cells Recieved from Network 1 30 4 NONE TFTP
48) Cells discarded for QBIN full 1 30 4 NONE TFTP
49) Cells discarded when QBIN>CLP 1 30 4 NONE TFTP
50) Cells Transmitted with CLP(Port) 1 30 4 NONE TFTP
51) BCM Cells Received(Port) 1 30 4 NONE TFTP
This Command: dspchstatcnf 5.1.100.100
Continue?
The dspchstathist command displays a history of statistics configured as enabled for a selected channel.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
cnfchstats, dspchstatcnf
| <channel> | specifies the channel. |
This command displays a history of the enabled statistics for a selected channel. It is intended for debugging problems with statistics gathering. It displays the data for the last five occurrences of the channel statistic. The channel statistic is selected from the list displayed when this command is first entered.
Use the dspchstatcnf to display the statistics enabled on the selected channel. Record the statistics types enabled, the collection interval, and owner; you will need this information to obtain the statistics history. Use cnfchstats to enable a statistic if it is not already enabled. Figure 1-54 illustrates a display for channel 6.1 packets transmitted (1 second interval) history.
gamma TRM SuperUser Rev: 8.4 Jan. 14 1997 13:53 PDT Packets Transmitted on Channel 6.1 Interval: 1 Minute(s), Data Size: 4 Byte(s), NO Peaks, Owner: Automatic 0 - 1699 -1 - 1698 -2 - 1698 -3 - 1699 -4 - 1698 -5 - 1698 -6 - 1698 -7 - 1699 -8 - 1697 -9 - 1699 Last Command: dspchstathist 6.1 7 1 AUTO Next Command:
The dspchstats command displays all statistics configured as enabled for a selected channel.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
cnfchstats, dspchstatcnf
| <slot.port.vci.vpi> | specifies the channel as defined by the slot, port, virtual channel indicator (VCI) and virtual path indicator (VPI). |
This command displays the enabled statistics for the selected channel. It is intended for debugging problems with statistics gathering. It displays the data for the last five occurrences of the channel statistic. The channel statistic is selected from the list displayed when this command is first entered.
Use the dspchstats command to display the statistics enabled on the selected channel. Record the statistics types enabled, the collection interval, and owner; you will need this information to obtain the statistics history. Use cnfchstats to enable a statistic if it is not already enabled. Figure 1-55 illustrates a display for channel on port 3, slot 1, with VPI and VCI both set to 1.
Channel Statistics for 3.1.1.1 Cleared: Date/Time Not Set (\) Snapshot
PCR: 500 cps Collection Time: 0 day(s) 00:03:47 Corrupted: NO
Traffic Cells Avg CPS %util
From Port : 11855761 52008 10401
To Network : 114332 501 100
From Network: 114303 501 100
To Port : 114303 0 501
Last Command: dspchstats 3.1.1.1.1
Next Command:
The dspclnstatcnf command displays statistics configured as enabled for a selected circuit line.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
cnfclnstats
<line> Specifies the circuit line in the format slot or slot.line. If the card has only one line, you can enter just the slot.
This command displays the circuit line statistics as enabled by the cnfclnstats command, by StrataView Plus, or by IPX or IGX features. See Figure 1-56 for an example display.
The Owner column shows what set the statistic. If the owner is "Automatic," the statistic was derived from the features. If the node name appears under Owner, the statistic came from StrataView Plus. If "User" is under Owner, the source of the statistic was the cnfchstats command.
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 18:14 PST Statistics Enabled on Circuit Line 7 Statistic Samples Interval Size Peaks Owner ----------------------------------- ------- -------- ---- ----- ---------- Frames Slips 60 0 4 NONE IPX Out of Frames 60 0 4 NONE IPX Losses of Signal 60 0 4 NONE IPX Frames Bit Errors 60 0 4 NONE IPX CRC Errors 60 0 4 NONE IPX Out of Multi-Frames 60 0 4 NONE IPX All Ones in Timeslot 16 60 0 4 NONE IPX Last Command: dspclnstatcnf 7 Next Command:
The dspclnstathist command displays a history of statistics enabled for a circuit line.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
cnfclnstats, dspclnstatcnf
| <circuit line> | specifies the circuit line in the format slot.line. If the card set supports only one line, you can enter just the slot number. |
This command displays the last five occurrences of the circuit line statistic. The circuit line statistic is selected from the list displayed when you first enter this command. Use the dspclnstatcnf to display the statistics enabled for the selected channel. Use cnfclnstats to enable a statistic.
Figure 1-57 illustrates a display for T1 circuit line 14 bipolar violations (60 second interval) history.
gamma TRM SuperUser Rev: 8.4 Jan. 14 1997 14:00 PDT Bipolar Violations on Circuit Line 14 Interval: 60 Minute(s), Data Size: 4 Byte(s), 10 S Peaks, Owner: Automatic 0 - 0(0) -1 - 0(0) -2 - 0(0) -3 - 0(0) -4 - 0(0) Last Command: dspclnstathist 14 1 60 AUTO Next Command:
The dspcnf command displays the status for the configuration save/restore processes on all nodes in the network.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
savecnf, loadcnf, runcnf
This command displays the status for the configuration save/restore process. The display lists the various nodes, the backup ID name of the saved configuration, the time and date saved, and the StrataView + terminal it is saved on. See Figure 1-58 for an example.
If the status displays "Reserved for Firmware" a firmware image is being maintained in memory after being loaded. Use the getfwrev 0.0 command to clear the firmware image. Likewise, if a configuration image is displayed, clear the old configuration image using savecnf clear or loadcnf clear.
sw83 TN StrataCom IPX 16 8.4 Feb. 24 1997 18:21 PST Node Backup ID Revision Date/Time (GMT) Status -------- --------- -------- ----------------- --------------------------------- sw78 mark 8.4.12 02/22/97 16:36:26 Unreachable sw81 mark 8.4.12 02/22/97 16:36:26 Unreachable sw84 mark 8.4.ay 02/22/97 16:36:26 Save on SV+ at sw78 complete sw79 mark 8.4.1b 02/22/97 16:36:26 Save on SV+ at sw78 complete sw86 mark 8.4.12 02/22/97 16:36:26 Unreachable sw83 mark 8.4.1b 02/22/97 16:36:26 Save on SV+ at sw78 complete Last Command: dspcnf Next Command:
The dspdnld command displays the status of a download to a nodes.
Jobs: No Log: Yes Lock: No Node Type: IPX, IGX, BPX
loadrev, getfwrev
This command displays the status of any software or firmware download operation from StrataView Plus to the node controller card. You should be connected to the node being downloaded either directly or via virtual terminal connection. The display download command shows:
This command can be used to check how far along the download has progressed. Figure 1-59 illustrates the command screen. Blocks of data already downloaded appear highlighted; the remaining blocks are appear dim. If there was no download initiated when this command is entered, the blocks of data will appear as all zeros.
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 18:23 PST dl_dest: Active CC dl_source: Active CC dl_type: None dl_image: ROM (NPC) 30010800 30020800 30030800 30040800 30050800 30060800 30070800 30080800 30090800 300A0800 300B0800 300C0800 300D0800 300E0800 300F0800 30100800 30110800 30120800 30130800 30140800 30150800 30160800 30170800 30180800 30190800 301A0800 301B0800 301C0800 301D0800 301E0800 301F0800 30200800 30210800 30220800 30230800 30240800 30250800 30260800 30270800 30280800 30290800 302A0800 302B0800 302C0800 302D0800 302E0800 302E3E7C Last Command: dspdnld Next Command:
The dsputl command displays the percentage utilization for data connections.
Jobs: No Log: No Lock: No Node Type: IPX, IGX
dsputl
| <start bslot> | specifies the slot where the data card is located. |
| [clear] | specifies that all data channel utilization buffers should be cleared after the display. |
This command displays the percentage utilization for the data connections starting at the back slot (bslot) number specified. All data connections for the node are displayed (maximum of 32).
The percentage is calculated by dividing the number of packets transmitted over the total number of packets allocated to the specified channel. Only transmit packet rates are used. If percentage utilization exceeds configured utilization the channel appears in reverse video.
Figure 1-60 illustrates a display where there is very low utilization (2%) on three of the four ports and no utilization of the forth port. The clear option clears all slots. Use dsputl to display utilization for voice channels.
sw150 TN StrataCom IGX 16 8.4 Feb. 1 1997 20:07 GMT Percentage utilization Last Cleared: Date/Time Not Set Snapshot From Slot 1 2 3 4 5 6 7 8 Slot 1 2 3 4 5 6 7 8 13 6 99 99 Last Command: dspdutl 13 Next Command:
The dspecparm command displays statistics configured as enabled for a selected CDP echo canceller.
Jobs: No Log: Yes Lock: No Node Type: IPX, IGX
cnfecparm
| <line> | specifies the circuit line to display. |
This command displays the Integrated Echo Canceller card parameters associated with the specified circuit line. These parameters are set using the cnfecparm command. Table 1-28 lists the parameter options. Figure 1-61 shows a typical display.
| Number | Parameter | Description |
|---|---|---|
| 1 | Echo Return Loss High | Maximum ERL required for echo canceller to be enabled. |
| 2 | Echo Return Loss Low | Minimum ERL required for echo canceller to be enabled. |
| 3 | Tone Disabler Type | Selection of protocol to enable tone disabler. |
| 4 | Non-Linear Processing | Selects type of post-canceller signal. |
| 5 | NLP Threshold | Threshold to enable non-linear processing. |
| 6 | Noise Injection | Determines if noise will be injected when NLP is active. |
| 7 | Voice Template | Selection of echo canceller template to use. |
sw83 TN StrataCom IPX 16 8.4. Feb. 1 1997 18:34 PST IEC Line 7 Parameters 1 CDP IEC Echo Return Loss High (.1 dBs) [ 60] (D) 2 CDP IEC Echo Return Loss Low (.1 dBs) [ 30] (D) 3 CDP IEC Tone Disabler Type [ G.164] 4 CDP IEC Non-Linear Processing [Center Clipper] 5 CDP IEC Non-Linear Processing Threshold [ 18] (D) 6 CDP IEC Noise Injection [ Enabled] 7 CDP IEC Voice Template [ USA] Last Command: dspecparm 7 Next Command: IPX SU/0036_
The dspfpdsc command displays FastPAD card descriptor information.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
dspfp, dspfps
This command displays FastPAD card descriptor information including:
Figure 1-62 illustrates the system response.
cc7 VT StrataCom IPX 32 8.4 Jan. 30 1997 11:08 PST
FastPad Card Descriptor Configuration
Card in Use : 01 Card State : 03 FPD CNFG indx : 00
Port Index Array
FastPad Port Indx
0 1 2 3 4 5 6 7 8 9 A B
0000 0001 0002 0003 0004 0005 0006 FFFF FFFF FFFF FFFF FFFF
Last Command: dspfpdsc 31.2.B
Next Command:
The dspfwrev command displays the status of card firmware revision image loaded in the controller card's RAM.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
getfwrev, burnfwrev
This command displays the revision level and an indication of the length of the firmware in the controller card. It may require two screens to display all the parameters. Figure 1-63 illustrates the screen display. This command can be used during firmware download to get an idea of how far along the downloading process has progressed. The blocks already downloaded appear normal. Blocks that are yet to be downloaded appear shaded.
If no getfwrev command was issued, nothing displays. If "Configuration image present" displayed, use the loadcnf clear command to clear this status.
gamma TRM SuperUser Rev: 8.4 Jan. 14 1997 14:28 PDT Firmware Size Status F.D.A 256 K Complete File Address Length CRC Burn Address File Address Length CRC Burn Address 1 800800 410 22996DDA 1 800800 410 22996DDA 3 805E60 480 85CB29EA 4 80A630 70 57A938AE 4 80A630 70 57A938AE 6 810000 10000 338E45F6 7 820000 4400 95990113 8 835000 1810 875771B2 9 8368A0 15D0 4C597B97 This Command: dspfwrev Continue?
gamma TRM SuperUser Rev: 8.4 Jan. 14 1997 14:29 PDT Firmware Size Status F.D.A 256 K Complete File Address Length CRC Burn Address 10 838000 20F0 0F4898D2 11 83A100 1E20 175F4B39 12 83C000 2FC0 F39B0302 13 83F000 1B0 E755FE4E 14 83FFFE 2 A1F4726D Last Command: dspfwrev Next Command:
The dsplnstatcnf command displays statistics configured as enabled for a selected line.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
cnflnstats
| <line> | specifies the line. |
This command displays the line statistics as enabled by the cnflnstats command, by StrataView Plus, or by node features. Figure 1-64 illustrates an example display.
The Owner column identifies who or what set the statistic. If the Owner column shows "Automatic," the node's features set the statistic. If the node name appears under Owner, StrataView Plus set the statistic. If the user name appears under Owner, the cnfchstats command executed from the command line interface set the statistic.
cc2 LAN StrataCom IPX 32 8.4 Jan. 30 1997 11:38 PST Statistics Enabled on Circuit Line 15 Statistic Samples Interval Size Peaks Owner ----------------------------------- ------- -------- ---- ----- ---------- Bipolar Violations 60 0 4 NONE IPX Frames Slips 60 0 4 NONE IPX Out of Frames 60 0 4 NONE IPX Losses of Signal 60 0 4 NONE IPX Frames Bit Errors 60 0 4 NONE IPX CRC Errors 60 0 4 NONE IPX Out of Multi-Frames 60 0 4 NONE IPX All Ones in Timeslot 16 60 0 4 NONE IPX Last Command: dsplnstatcnf 15 Next Command:
The dsplnstathist command displays a history of statistics configured as enabled for a selected line.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
cnflnstats, dsplnstatcnf
| <line> | specifies the line. |
This command displays the last five occurrences of the line statistic. The line statistic is selected from the list displayed when this command is first entered. Use the dsplnstatcnf to display the statistics enabled on the selected channel. Use cnflnstats to enable a statistic.
Figure 1-65 illustrates an example display.
cc2 LAN StrataCom IPX 32 8.4 Jan. 30 1997 11:40 PST Command history 12: cnftcparm 11: cnftcpparm 32 10: cnfnwip 192.38.38.4 9: cnfnwip 192.38.38.2 255.255.255.0 8: help cnft 7: dspasich 6: dspasich 5: dspasich 4: dspbuses 3: dsplnstatcnf 15 2: dsplnstathist 15 5 40 1: dsplnstathist 15 5 40 IPX Last Command: dsplnstathist 15 5 40 IPX Next Command:
The dspplnmcons command displays the number of packet line connections by master node.
Jobs: No Log: No Lock: No Node Type: IPX, IGX
none
| <line number> | specifies the line number for gathering the connection count. |
| l | refers to local connections. |
| j | refers to junction. |
Displays the number of connections attached to each master node on a line. See Figure 1-66.
TN StrataCom IPX 16 8.4 Jan. 25 1997 18:31 PST Connection Counts For PLN 11 Mst Node Conns Mst Node Conns Mst Node Conns Mst Node Conns sw81 48 sw83 400 sw84 48 sw79 500 sw86 100 Last Command: dspplnmcons 11
The dspportstatcnf command displays statistics configured as enabled for a selected frame relay port.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
cnfportstats
| <port> | specifies the port. Do NOT enter the DLCI for frame relay ports. |
This command displays the enabling of frame relay port statistics. These are the statistics set by the cnfportstats command, by StrataView Plus, or by node features. See Figure 1-67 for an example.
The owner column shows what set the statistic. If "Automatic", it is set by features, if node name it was is set by StrataView Plus, if user it was set with the cnfportstats command.
gamma SV+ YourID Rev: 8.4 Jan. 14 1997 13:47 PDT Statistics Enabled on Port 8.1 Statistic Samples Interval Size Peaks Owner ------------------------------------ ------- -------- ---- ----- ---------- Frames Received 5 60 4 1 M beta Frames Received 5 60 4 1 M beta Bytes Received 5 60 4 1 M beta Last Command: dspportstatcnf 8.1
The dspportstathist command displays a history of statistics configured as enabled for a selected port.
Jobs: No Log: Yes Lock: Yes Type: IPX, IGX
cnfportstats, dspportstatcnf
| <port> | specifies the port. |
This command displays the data for the last five occurrences of the port statistic. The port statistic is selected from the list displayed when this command is first entered. Use the dspportstatcnf to display the statistics enabled on the selected port. Use cnfportstats to enable a statistic.
Figure 1-68 illustrates a display for FR port 8.2 DE Frames Dropped (1 second interval) history.
D.1 gamma TRM SuperUser Rev: 8.4 Jan. 14 1997 14:15 PDT DE Frames Dropped on Port 8.2 Interval: 1 Minute(s), Data Size: 4 Byte(s), NO Peaks, Owner: IPX User 0 - 0 -1 - 0 -2 - 0 -3 - 0 Last Command: dspportstathist 8.2 19 1 USER Next Command:
The dspqstats command displays the collected queue-based statistics for the selected node slot.
Jobs: Yes Log: Yes Lock: Yes Node Type: BPX
cnfqstats
| <slot number> | specifies the shelf and slot. |
This command displays all active BPX node queue-based slot statistics. See Figure 1-69, below.
sw47 TN StrataCom BPX 15 8.4.0 Jan. 26 1997 15:41 PST Line 3.6 Status: Clear - OK Clrd: 03/26/96 15:33:16 Queue Number/Desc.: 0/CBR 1/VBR 2 3 4 5 6 ..... State: active active inact. inact. active inact. inact. Qbin Depth: 100 200 - - 300 0 0 Priority: 1 2 - - 3 0 0 Algorithm: - - - - - - - CLP Hi / Low: 80/60 80/60 - - 90/70 - - EFCI Threshold: 80 90 - - 70 - - Min. Serv. Rate: 65 65 - - 80 - - Cells Served: 96 45 - - 34 - - CurQbin Depth: 2 8 - - 1 - - MaxQbin Depth: 10 30 - - 2 - - Discard Sel: 0 0 - - 1 - - Discard Thres: 90 100 - - 95 - - Cells Received: 96 45 - - 34 - - CLP Drop Cells: 0 0 - - 0 - - Ovflw Drop Cells: 0 0 - - 0 - - Dis. Qbin Drop Cells: 0 0 - - 0 - - Last Command: dspqstats 3.6 Next Command:
The dsprevs command displays the system software revision loaded and running on all nodes in the network.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
runrev, loadrev, forcerev
This command displays the configuration and status of the primary and secondary software revisions for all nodes in the network. The primary revision is the software that is running the node. The secondary revision is the software that is available in memory but not being run. Table 1-29 lists the various status messages. Figure 1-70 illustrates a typical display.
| Status | Description |
|---|---|
| unavailable | The revision is currently unavailable for the node displayed. The revision has not propagated to the node yet. |
| available | The node has located the specified revision but has not yet downloaded it. |
| partial | The revision was only partially downloaded. Indicates the download was temporarily interrupted. |
| downloading | The revision is in the process of being downloaded. Blocks of data are being transferred. |
| loaded | The revision has completed downloading but is not ready for running. |
| upgrading | The controller card is being upgraded by the current revision. This process generally occurs immediately follows the downloading. |
| upgraded | The upgrade procedure has been completed. |
| running | The primary revision is currently being used to run the node. |
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 19:03 PST
------ Primary ------ ----- Secondary -----
NodeName Status Revision Status Revision
sw78 Running 8.4.12
sw81 Running 8.4.12
sw84 Running 8.4.ay
sw79 Running 8.4.1f
sw86 Running 8.4.12
sw83 Running 8.4.1f
Last Command: dsprevs
Next Command:
D1.jea TRM StrataCom BPX 15 8.4 Jan. 14 1997 12:20 PDT Robust Communications Statistics since : Date/Time Not Set Updts msg xmit: 0 Updts msg ackd: 0 Updts ack tout: 0 LCBs freed: 0 Updts ack reset: 0 Last Command: dsprobparm Next Command:
The dsprobst command displays the statistics associated with the Robust Alarms feature.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
cnfrobparm
| [clear] | specifies that the statistics buffers should be cleared after the display. |
This command displays the statistics associated with the Robust Alarms messages between the node and StrataView Plus NMS. The optional clear field clears the statistics buffers. Figure 1-72 illustrates a sample display screen.
cc2 LAN StrataCom IPX 32 8.4 Jan. 30 1997 11:40 PST Command history 12: cnftcparm 11: cnftcpparm 32 10: cnfnwip 192.38.38.2 9: cnfnwip 192.38.38.2 255.255.255.0 8: help cnft 7: dspasich 6: dspasich 5: dspasich 4: dspbuses 3: dsplnstatcnf 15 2: dsplnstathist 15 5 40 1: dsplnstathist 15 5 40 IPX Last Command: dsplnstathist 15 5 40 IPX Statistic not enabled for specified object Next Command:
The dsprrst command displays the connection rerouting statistics for the network.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
rrtcon, drtop
| [-j] | specifies that the reroute statistics display should include junction nodes. |
| [clear] | specifies that the reroute statistics buffers should be cleared after the display. |
This command displays the statistics related to connection rerouting resulting from failed trunks. These statistics may be useful in determining the performance of the reroute algorithm. Use the clear option to clear the counters before accumulating the statistics. Table 1-30 lists the applicable reroute statistics. Figure 1-73 illustrates a typical display.
| Statistic | Description |
|---|---|
| Number of Completed Routes | This is the total number of connections routed since the NPC rebuilt. |
| Number of Failed Routes | This is the number of attempted reroutes that failed for any reason. |
| Number of Collisions | When a reroute is in progress, the initiating node locks all nodes on the route until the rerouting process is complete. If another node attempts to reroute through one of the locked nodes, a collision is reported and the second node must retry after a delay. |
| Max. # of Consec. Collisions | Is the count of consecutive collisions as defined above. |
| Max/Avg Secs To Select Route | Time taken within the initiating node to select a new route. |
| Max/Avg Secs To Perform Route | Time taken to contact and lock the nodes on the new route and perform the rerouting process. |
| Avg Secs to Route a Conn: | Time to perform a reroute divided by the average number of connections in a bundle. |
| % of Collisions/Rrt Attempt | Another statistic derived from the number of collisions and the number of reroute attempts. |
| Max Secs To NOT find Route | Similar to "max secs to select a route" except that the algorithm finished and no route was found. |
| Number of Routes not found | Number of routes not found in the rerouting process. This parameter updates periodically as a heartbeat to check for activity. |
| # of Rrts with rrt req_bit set | A measure of the connections awaiting rerouting. When rrt_req bit is set, indicates a reroute is not totally successful or trunk deletions or loading additions mean connections must be rerouted. Cleared by rerouting the connection. |
| Address of Forced Rrt Counts | A NPC memory address for database information. |
| Max routes checked in search | Maximum no. of PLNs examined in any one search for a new route. |
| Max good rts checked in search | Maximum number of possible routes found before the search was terminated. Should be 1. |
| # our lns rmvd from under us | Measure the number of changes to topology and loading that occurred while rerouting was in progress. |
| # lines rmvd out from under us | Same as above. |
sw91 TN StrataCom IPX 8 8.4 Feb. 1 1997 20:56 GMT
Connection Routing Statistics LOC_DOMAIN
Number of Completed Routes: 0 Blocked by other st machines: 273
Number of Failed Routes: 0 Timeouts waiting for ACK/NACK: 0
Number of Collisions: 0 Number of Routes Not found: 0
Max # of Consec Collisions: 0 # of Rrts with rrt_req bit set: 0
Max Secs To Select Route: 0.000 Address of Forced Rrt Counts: 30CDC386
Max Secs To Perform Route: 0.000 Max routes checked in search: 0
Max Bundle Size Routed: 0 Max good rts checked in search: 0
Avg Secs To Select Route: 0.000 # nibs rmvd out from under us: 118
Avg Secs To Perform Route 0.000 # our lns rmvd from under us: 0
Avg Secs To Route a Conn: 0.000 # lns rmvd from under us: 66
Avg Bundle Size Routed: 0 Number of conid conflicts: 0
% of Collisions/Rrt Attempt: 0% Number of LCON deroutes: 0
Max Secs To NOT find Route: 0.005 Number of NW_LCON deroutes: 0
Times conns deletd while rtng: 0 Number of GLCON lcl deroutes: 0
Last Command: dsprrst
Next Command:
The dspsig command displays the current signalling state received at the node from the specified voice channel.
Jobs: No Log: No Lock: No Node Type: IPX, IGX
cnfclnsigparm, cnfrcvsig, cnfclnsigparm
| <start_channel> | the first voice channel to be monitored. |
This command displays the current signalling state received at the node from the specified voice channel. The status of the transmit and receive A and B signalling bits (for DS1 trunks) or A, B, C and D signalling bits (for E1 trunks) are displayed as a 0 or 1. The status of the bits (0 or 1) depends on the signalling type utilized on the connection displayed. The transmit direction of transmission is towards the remote node; the receive direction is towards the local circuit line.
The dspsig command can be used to verify the connection signalling type. Figure 1-74 illustrates a typical screen. If you compare the A/B bit states on-hook and off-hook with those shown in the dspchcnf command, you will note that the node passes signalling straight through. The signalling definition is only important for monitoring the on-hook/off-hook state and setting conditioning patterns.
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 19:25 PST
Signalling Information
From 7.1 TXAbit TXBbit TXCbit TXDbit RXAbit RXBbit RXCbit RXDbit no_serv
7.1-15 1 1 0 1 1 1 0 1
7.17-31 1 1 0 1 1 1 0 1
Last Command: dspsig 7.1
Next Command:
The dspslot command displays system information associated with a specific card slot in the node.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
none
| <slot number> | specifies the shelf slot number. |
This command displays system information associated with a specific card slot in the node. It is used for debugging card failures. When a card failure is reported to Cisco TAC, the TAC engineer records the parameters for the associated slot displayed using the dspslot command.
The information displayed by the dspslot command is unique to the card slot in the shelf and is used primarily by the controller card to supervise background system tasks. Table 1-31 lists the slot parameters displayed. Figure 1-75 illustrates a typical display.
Use this command for more information on failed cards. Print and return to Cisco with faulty cards for better diagnosis of the failure.
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 19:27 PST
Card Data Base for FRP card in slot 6 at address 30BD820C
Logical Card 6 Test in Prog 0
Verify DB Flag 0 Slft Res Abort 0
Info Ptr 30B88C2C Slft Abort 0
Last Event TEST_FREE Last Test BKGD_TEST
Fail Inter 0 FRP Test Fail 0
Selftest Fail 0 FRP Test Fail I 0
Selftest Inter 0 FRP Port Test Fail 0
Selftest Timeout 0 FRP Port Capacity 31
Con Test Fail 0 FRP Line Capable 1
Red LED Flag 0 FRP V35 Capable 0
Restart Reason Not maintained FRP X21 Capable 0
Selftest Results FRP NNI/CLLM Cap 1
FRP CGW/ATFR Cap 1
Last Command: dspslot 6
Next Command:
| Item | Parameter | Description |
|---|---|---|
| 1 | Logical Card | This is a number representing a particular card type. |
| 2 | Verify DB Flag | Verify database flag. Concerned with database and memory. |
| 3 | Info Ptr | Information pointer. Concerned with database and memory. |
| 4 | Last Event | This is the previous state of the card known to the NPC. |
| 5 | Fail Inter | Indicates intermittent card failure. |
| 6 | Selftest Fail | Indicates self-test fail condition. |
| 7 | Selftest Inter | Indicates intermittent self-test failure. |
| 8 | Selftest Timeout | Self-test routine timed out before completing. |
| 9 | Con Test Fail | Indicates failure of the test con command. |
| 10 | Red LED Flag | Indicates front panel FAIL LED on. |
| 11 | Restart Reason | Reason for last card reset. |
| 12 | Selftest Results | Results of last self-test for card. |
| 13 | Test in Prog | Indicates card test is in progress. |
| 14 | Slft Res Abort | Not used. |
| 15 | Slft Abort | Not used. |
| 16 | Card Stats Up | A "1" indicates statistics are being collected on this card. |
| 17 | Sib Pointer | Pointer to database concerning statistics. |
| 18 | Summary stats | Pointer to database concerning statistics. |
| 19 | Detailed stats | Pointer to database concerning statistics. |
| 20 | Bus Mastership | For BCC, this indicates whether this is the slave BCC. For other cards, this is not used. |
| 21 | Last Test | Last test performed on card in this slot. |
The dspslotstatcnf command displays statistics configured as enabled for a selected slot where a Monarch card resides.
Jobs: No Log: Yes Lock: Yes Node Type: BPX
cnfslotstats
| <slot> | specifies the slot where the Monarch card resides. |
This command displays the enabling of Monarch card slot statistics. These are the statistics set by the cnfslotstats command, by StrataView Plus, or by node features. See Figure 1-76 for an example.
The owner column shows what set the statistic. If "Automatic", it is set by features, if node name it was is set by StrataView Plus, if user it was set with the cnfslotstats command.
The dspslotstathist command displays a history of statistics configured as enabled for a Monarch card slot.
Jobs: No Log: Yes Lock: Yes Type: BPX
cnfslotstats, dspslotstatcnf
| <slot> | specifies the slot. |
This command displays the data for the last five occurrences of the slot statistic. The statistic is selected from the list displayed when this command is first entered. Use the dspslotstatcnf to display the statistics enabled on the selected slot. Use cnfslotstats to enable a statistic.
The dspstatmem command displays memory usage for statistics collection.
Jobs: No Log: Yes Lock: No Node Type: IPX, IGX, BPX
none
This command displays memory usage for statistics collection. It is intended for debugging statistics collection problems, not everyday use. The command shows the amount of controller card memory allocated by the user to statistics display (defaults to 650 Kbytes).
The memory occupied by USER is used for user-enabled statistics. Figure 1-78 illustrates an example screen. The memory occupied by USER figure is that used by the StrataView Plus user. Memory occupied by AUTO is that used by node features.
sw83 TN StrataCom IPX 16 8.4 Feb. 1 1997 19:29 PST User Configured Statistics Memory (In bytes) = 624640 Memory Occupied by USER (In bytes) = 0 Memory Occupied by AUTO (In bytes) = 21584 Last Command: dspstatmem Next Command:
The dspftcpparm command displays the TCP bandwidth throttle parameter.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
cnftcpparm
This command displays the TCP bandwidth throttle parameter. The following illustrates an example display.
cc2 LAN StrataCom IPX 32 8.4 Jan. 30 1997 11:42 PST NWIP Bandwidth Throttle (Kbytes/sec): 32 Last Command: dsptcpparm Next Command
The dsptrkcons command displays the number of connections routed over the specified trunk. This command applies to physical and virtual trunks.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
dsptrkmcons, dspplnmcons
| <line number> | trunk number. |
This command displays the total number of connections being carried by the specified trunk. The connections are summed for each terminating node in the network and lists the connection count for the transmit direction (out of the node).
This command is useful in determining the source of dropped packets in cases where the specified trunk is oversubscribed. Use the dsptrks command to list the trunks that originate at each node. Next, use the dsptrkcons to determine the number of connections (the more connections per trunk the greater the possibility of over-subscription). Then use the dsprts command to identify any through nodes (where the trunk is not terminated). Finally, look at the utilization factor for each of these lines using the dsputl and dspdutl commands. Figure 1-80 illustrates the dsptrkcons command display.
batman TN StrataCom BPX 15 8.4 Jan. 9 1997 15:57 GMT Connection Counts For TRK 5.1 Src Node Conns Src Node Conns Src Node Conns Src Node Conns batman 1765 Last Command: dsptrkcons 5.1 Next Command:
The dsptrkmcons command displays the number of connections routed over the specified trunk (BNI) by the master node.
Jobs: No Log: Lock: Node Type: IPX, IGX, BPX
dsptrkcons
| <line number> | specified trunk number. Note that in a BPX, the line number must include a port number. |
This command displays the total number of connections being carried by the specified trunk. Rather than showing the remote end of the connection, the display lists the connection and the node that owns that connections.
This command is useful in determining the source of dropped packets in cases where the specified trunk is oversubscribed. First, use the dsptrkmcons command to list the trunks that originate at each node (the more connections per trunk, the greater the possibility of over-subscription). Next, use the dsprts command to identify any through-nodes (on which the trunk is not terminated). Finally, look at the utilization for each of these lines by using the dsputl and dspdutl commands. Figure 1-81 illustrates the dsptrkmcons command display.
sw81 TN StrataCom BPX 15 8.4 Jan. 26 1997 13:16 PST Connection Counts For TRK 6.1 Mst Node Conns Mst Node Conns Mst Node Conns Mst Node Conns sw86 26 Last Command: dsptrkmcons 6.1 Next Command:
The dsptrkstatcnf command displays the enabled statistics a physical or virtual trunk.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
cnftrkstats
| <line> | specifies the trunk: line can have the form slot, slot.port, or slot.port.vtrk. The format depends on whether the trunk card has only one or more physical ports and whether the trunk is a virtual trunk. |
This command displays the statistics configured as enabled for a selected trunk. It is intended for debugging statistics collection problems. It displays the trunk statistics set by the cnftrkstats command, by StrataView Plus, or by node features. Figure 1-82 illustrates an example display for an ATM trunk.
The owner column shows what set the statistic. If "Automatic", it is set by features, if node name it was is set by StrataView Plus, if user it was set with the cnftrkstats command. The display may take up to four screens to display completely depending on statistics displayed.
sw86 TN StrataCom BPX 15 8.4 Feb. 1 1997 20:24 PDT
Statistics Enabled on Trunk 6.2
Statistic Samples Interval Size Peaks Owner
------------------------------------ ------- -------- ---- ----- ----------
3) Out of Frames 60 0 4 NONE BPX
4) Loss of Signal 60 0 4 NONE BPX
29) Line Code Violation 60 0 4 NONE BPX
41) BIP-8 Errors 60 0 4 NONE BPX
46) HCS Errors 60 0 4 NONE BPX
48) Tx Voice Overflow Drpd Cells 60 0 4 NONE BPX
49) Tx TS Overflow Drpd Cells 60 0 4 NONE BPX
50) Tx NTS Overflow Drpd Cells 60 0 4 NONE BPX
51) Tx Hi-Pri Overflow Drpd Cells 60 0 4 NONE BPX
52) Tx BData A Overflow Drpd Cells 60 0 4 NONE BPX
53) Tx BData B Overflow Drpd Cells 60 0 4 NONE BPX
This Command: dsptrkstatcnf 6.2
Continue?
sw86 TN StrataCom BPX 15 8.4 Feb. 1 1997 20:26 PDT
Statistics Enabled on Trunk 6.2
Statistic Samples Interval Size Peaks Owner
------------------------------------ ------- -------- ---- ----- ----------
167) Tx CBR Overflow Drpd Cells 60 0 4 NONE BPX
168) Tx VBR Overflow Drpd Cells 60 0 4 NONE BPX
169) Tx ABR Overflow Drpd Cells 60 0 4 NONE BPX
Last Command: dsptrkstatcnf 6.2
Next Command:
The dsptrkstathist command displays a history of configured statistics for a physical or virtual trunk.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
cnftrkstats, dsptrkstatcnf
| <trunk> | specifies the trunk. |
The dsptrkstathist command is a statistics debugging command. It displays the data for the last five occurrences of the selected statistic. The available trunk statistics appear on screen upon entry of the dsptrkstathist command. (The cnftrkstats command enables individual statistics. The dsptrkstatcnf command displays the enabled statistics for a trunk.) Figure 1-84 displays a statistic history for virtual trunk 1.1.1. The statistic is TX ABR Overflow Dropped Cells. This is statistic number 169, which execution of dsptrkstatcnf shows as enabled for this trunk. (If a disabled statistic is selected, a message stating this appears above the command line prompt.) The entered bucket interval is 0 minutes, which means that only the preceding 60 seconds worth of gathered data for number 169 appears.
sw97 TN StrataCom BPX 15 8.4 Jan. 9 1997 12:42 GMT Tx ABR Overflow Drpd Cells on Trunk 1.1.1 Interval: 10 Second(s), Data Size: 4 Byte(s), NO Peaks, Owner: IPX 0 - 0 -11 - 0 -1 - 0 -12 - 0 -2 - 0 -13 - 0 -3 - 0 -14 - 0 -4 - 0 -15 - 0 -5 - 0 -16 - 0 -6 - 0 -17 - 0 -7 - 0 -18 - 0 -8 - 0 -19 - 0 -9 - 0 -20 - 0 -10 - 0 -21 - 0 This Command: dsptrkstathist 1.1.1 169 0 BPX Continue?
The dsputl command displays the utilization factor for all voice connections on a specified circuit line.
Jobs: No Log: No Lock: Yes Node Type: IPX, IGX
dspdutl
| <bslot> | specifies the shelf back slot number of the circuit line. |
| [clear] | Directs the controller card to clear the utilization counters after being displayed. |
This command displays the actual percentage utilization for all voice connections on a single circuit line specified by the back slot (bslot) number. The percentage is calculated by dividing the number of packets transmitted over the total number of packets allocated to the specified channel. Only transmit packet rates are used. If percentage of actual utilization exceeds the configured utilization the channel appears in reverse video.
Figure 1-85 illustrates a typical display. In this example, the connections from 11.1 to 11.11 use VAD and the connections from 11.12 to 11.17 do not. The connections using VAD do not use any network bandwidth (0 utilization) until the connection is used. The other connections utilize the full bandwidth (100% utilization) even though they may be idle.
Use the dspdutl command to display utilization for data channels.
gamma TRM SuperUser Rev: 8.4 Jan. 14 1997 16:36 PDT Percentage utilization Last Cleared: Date/Time Not Set Snapshot CLN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 11 0 0 0 0 0 0 0 0 0 0 0 0 99 99 99 CLN 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 11 99 Last Command: dsputl 11 Next Command:
The forcerev command forces a software revision to be sent down a trunk to a remote node.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
dsprevs, loadrev
| <line number> | specifies the trunk number used to send the revision. |
| <primary/secondary> | specifies which revision is to be sent. |
| <revision> | specifies the software revision to be forced down the line. |
This command sends a change revision message blindly down the specified trunk from the local node to the remote node. This allows primary revisions to be changed regardless of communication breaks and unreachable nodes. Usage of this command should only be necessary if a problem results in inconsistent revisions throughout a network.
Figure 1-86 illustrates an example screen. If the local node does not have the SW revision specified, the system will display "Unavailable X.X" as indicated. Use the getfwrev command to load the desired software revision into the node. Use the dsprevs command to display the revisions available on each node in the network.
![]() | Caution Use this command only when requested by StrataCom and under StrataCom supervision. |
alpha TRM SuperUser Rev: 8.4 Jan. 14 1997 13:42 PDT
------ Primary ------ ----- Secondary -----
NodeName Status Revision Status Revision
NodeName Status Revision Status Revision
gamma Running 8.4
Last Command: forcerev 10 s 7.2
Next Command:
The getfwrev command gets and loads a firmware image from StrataView, StrataView Plus, or a remote node into the specified node(s).
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
burnfwrev, dspfwrev, dspdnld
| <card type> | specifies the type of card, such as BXM, BCC, ASI-T3, ASI-155, and so on. Note that for the ASI cards, you should "ASI-155" for the ASI-155 but enter "ASI-T3" for all other types of ASIs. |
| <image name> | specifies the name assigned to the firmware revision. Image names are generally in all capital letters and are case-sensitive when being entered. |
| <nodename> | specifies the node on which to load the revision. |
The getfwrev command gets and loads a firmware revision image into the specified node's control card memory. The firmware image must reside in the StrataView or StrataView + terminal before you execute getfwrev. You can subsequently load the firmware image into specific service cards in the node by using the burnfwrev command.
After you first enter the getfwrev command, the status is temporarily "Unavailable" while the node attempts to locate the source of the firmware image. After the download begins, a list of all files that make up the image appears on screen and, as the download progresses, the address of each file is updated.
The following examples illustrate the varieties of syntax:
![]() | Caution Do not confuse getfwrev with loadrev: the loadrev command loads system software. |
The loadcnf command loads a configuration image from StrataView Plus to a node.
Jobs: Yes Log: Yes Lock: Yes
Node Type: IPX, IGX, BPX, IPX/AF, IGX/AF
dspcnf, runcnf, savecnf
| <backup_id > | specifies the name of the backup configuration file to be loaded. Configuration names are case-sensitive. |
| <clear> | specifies that the control card buffer area used for loading a configuration be cleared. |
| <node name> | specifies the target node where the backup configuration file is to be loaded. |
| <source_SV_node> | specifies the node connected to the StrataView Plus where the configuration file backup_id resides. |
This command causes a saved network configuration file to be downloaded from StrataView Plus to one node or all nodes. (See savecnf.) The configuration image downloaded is temporarily stored in a buffer area in a node's controller card memory. The process runs in the background and may take several minutes if the configuration file is large. Although loaded, the configuration is not yet restored. The configuration is restored to the controller card's BRAM memory using the runcnf command.
After loading and restoring a network configuration, the control card buffer area used for this purpose should be cleared so it is available for other downloading processes, such as that of firmware. To clear the buffer area, execute loadcnf with the clear parameter specified instead of backup_id. Specify the buffer of an individual node with node_name or all nodes with *. For the purpose of clearing the buffer area, do not specify the source_SV_node parameter.
To execute this command on an IPX/AF or IGX/AF interface shelf, telnet to the shelf or use a control terminal attached to the shelf.
The loadrev command loads a secondary system software revision image from StrataView or StrataView Plus into a node.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
runrev, dsprevs, cnfdlparm
| <revision > | specifies the revision level of the system software file to be loaded. |
| <nodename> | specifies the target node where the secondary revision is to be loaded. |
| <*> | is a shorthand notation used to specify all nodes in the network. |
This command loads the secondary revision system software for the specified nodes. The secondary revision system software is the code that is loaded onto a controller card but is not being run. Use the runrev command after loading of a revision is complete to make the secondary revision the primary revision. The previous primary revision then becomes the secondary.
Examples of this command:
After entering the command, system responds with: "Enter Rev Number:" The dsprevs command is used to observe the software revisions that are currently loaded into the controller memory. The dspdnld command is used to display a running picture of the status of the download procedure once it has commenced.
![]() | Caution Do not confuse loadrev with getfwrev.: the getfwrev command loads firmware. |
The prtcderrs command prints out detailed card failure information.
Jobs: Yes Log: No Lock: Yes Node Type: IPX, IGX, BPX
clrcderrs, dspcderrs
| <slot > | specifies the shelf slot where the selected card is installed. |
Prints a history of card failures associated with a specified slot on the network printer. If no argument is specified, a summary is printed, indicating the slots that have failures recorded against them. Refer to dspcderrs command for an example of a typical card error record that might be printed.
The rrtcon command is used to manually reroute one or more connections.
Jobs: Yes Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
drtop
| <group | channel(s)|*>: | specifies a group, a channel, or a range of channels to be rerouted. A '*' specifies all locally owned groups and connections. |
This command forces a group, channel or range of channels to be rerouted. If a free-routing connection is rerouted by the system for whatever reason, it will not automatically return to its original route when the trouble clears. This may leave the connection on a path that is not the most direct or cost effective.
This command can be used to force a reroute that will likely put the connection back to its original route if available. Over time, many routes may need to be rerouted back to their original paths. In this case, use the "*" to reroute all connections.
To use this command you must first vt to the node that owns the connection (local node). If not at the local node, the system displays, "This node is not owner of the connection(s)."
There is no provision for specifying a route. The node determines the connection route according to the same rules that are used when adding a new connection. If there is no network bandwidth available to reroute the connection, the connection will be marked as failed.
![]() | Caution Entering this command on a connection that is in service should be done with some discretion as the reroute will interrupt service for as long as it takes to reroute the connection. |
The rststats command resets the statistics collection time for the tststats command.
Jobs: Yes Log: No Lock: Yes Node Type: IPX, IGX
tststats
This command resets the collection time for the tststats command. The tststats command displays a test statistics summary. Before there will be any meaningful statistics, the tstcon command must be performed on one or more network connections. Refer to the Command Reference for information on the tstcon command. Figure 1-87 illustrates the system response.
alpha32 LAN StrataCom IPX 32 8.4 Jan. 30 1997 13:35 PST Command history 12: 11: 10: 9: 8: 7: 6: 5: 4: 3: 2: 1: rststats This Command: rststats Warning: This command clears all statistics Continue?
The runcnf command restores a network configuration image at one or all nodes.
Jobs: No Log: Yes Lock: Yes
Node Type: IPX, IGX, BPX, IPX/AF, IGX/AF
savecnf, loadcnf, clrcnf
| <backup_id> | specifies the name of the configuration image loaded from StrataView Plus. Configuration names are case-sensitive. |
| <node_name> | specifies the node name to receive the configuration. An asterisk (*) specifies all nodes. |
This command restores the specified configuration to the controller card's BRAM memory and overwrites the current configuration. Once restored, the specified node (or all nodes) rebuilds with the restored configuration image. To execute this command on an IPX/AF or IGX/AF interface shelf, telnet to the shelf or use a control terminal attached to the shelf.
This command is usually run after a previous configuration has been lost. If doubts exist about the state of the configuration at other nodes in the network, load the configuration into all nodes by specifying "*" for the node name. The new configuration must have previously been loaded into the controller buffer area with the loadcnf command.
![]() | Caution All network nodes must be run with the same configuration. |
The system may display two warnings in response to the runcnf command:
A. When single node specified:
B. When all nodes specified:
If a single node is not reachable, responding with a "Y" does not affect the operation of the network. If node(s) do not all have the specified configuration or all are unreachable, it is not recommended that you continue until after the problem is resolved.
The runrev command runs a specific revision of the system software revision at a node.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX, BPX
dsprevs, loadrev, cnfdlparm
| <backup_id> | specifies the name of configuration image loaded from StrataView Plus. Image names are generally in all capital letters and are case-sensitive when being entered. |
| <node_name> | specifies the node name to rebuild with a new configuration. |
| '*' | is a shorthand notation used to specify all nodes in the network. |
This command sets the primary revision for the specified nodes. The primary software revision is the one that is actively controlling node operation. A non-active secondary revision that does not match the primary revision may also be loaded in the controller. To set the primary software revision, enter:
After entering the command, system responds with "Enter Rev Number". Use the dsprevs command to determine which rev(s), primary and secondary, are available on the node. The runrev command will be ignored if the required revision is not present on the node.
You may need to load the new revision onto the StrataView Plus terminal and then use loadrev command to download the new software image into the standby controller before you issue the runrev command. If you enter a revision number that does not exist at the node, the system displays the message
"Warning--the node does not have the specified revision. Continue? Y/N
![]() | Caution All network nodes must be run with the same software revision or abnormal network operation will be experienced. |
If you respond "no", the system takes you back to the main StrataView Plus prompt and you have an opportunity to change the rev. number and make a second attempt to run the corrected revision.
The savecnf command saves a configuration image on a StrataView Plus workstation disk.
Jobs: Yes Log: Yes Lock: Yes
Node Type: IPX, IGX, BPX, IPX/AF, IGX/AF
loadcnf, runcnf, clrcnf
| <backup_id> | specifies the name of a configuration to be saved on StrataView Plus. The Backup ID must be 1-8 alphanumeric characters with the first character being alphabetic. Configuration names are case-sensitive. |
| <clear> | specifies that the buffer area should be cleared. |
| <node_name> | specifies the node name to save configuration on. '*' may be specified to indicate all nodes. |
| <dest_SV_node> | specifies the node name where StrataView Plus is connected and that is to receive the specified backup_id. |
| <dest_SV_IP> | for IPX/AF or IGX/AF interface shelves only, this optional specification is the IP address of the StrataView Plus station intended to receive the configuration image. |
The savecnf command has two possible applications. It saves all the configurations for the nodes in a routing network, or it saves the configuration of one IPX/AF or IGX/AF interface shelf to a specific StrataView Plus workstation. After you have saved the configuration, you can restore it to BRAM by using the loadcnf and runcnf commands. You should use the savecnf command in the following situations:
In a routing network, savecnf saves a configuration image for one node or all routing nodes (node_name = *) on the StrataView Plus workstation specified by dest_SV_node.
To execute savecnf on an IPX/AF or IGX/AF, either telnet to the shelf or use a control terminal attached to it: savecnf saves a configuration image of only this interface shelf. The image resides on the workstation with the IP address in the parameter dest_SV_ip. (In a routing network, dest_SV_ip is not necessary.) Note that node_name and dest_SV_node must both be the name of the IPX/AF or IGX/AF. The IP address of the destination StrataView Plus workstation uniquely identifies where to store the configuration image.
The setfpevt command enables the reporting of FastPAD events.
Jobs: No Log: Yes Lock: Yes Node Type: IPX, IGX
clrfpevt, dsplog
| <slot.port> | specifies the slot and port of the FastPAD. |
Executing setfpevt restarts FastPAD event logging after you have stopped logging by using clrfpevt.
The reason for executing clrfpevt is to prevent the large number of logged events that accumulate when certain user-controlled disruptions occur. Without suspension of event-logging, the number of events caused by the disruption can cause the FastPAD to become unreachable. Examples of these events are:
setfpevt 9.3
The example command resumes event logging for the FastPAD connected to port 9.3.
sw152 TN StrataCom IGX 16 8.4 Nov. 26 1997 15:14 GMT
Most recent log entries (most recent at top)
Class Description Date Time
Info FP fp93 event: 9.3.B grp:0-0 code:12 11/26/97 15:13:28
Info FP fp93 event: 9.3.B grp:0-0 code:1 11/26/97 15:13:28
Info User StrataCom logged in (Local) 11/26/97 14:28:40
Info User StrataCom logged in (Local) 11/26/97 12:56:49
Info Invalid Login Attempt via LAN Port (Local) 11/26/97 12:56:46
Info User StrataCom logged in (Local) 11/26/97 11:31:51
Info AD 9.2.3 dallas COM OK (Kickoff) 11/26/97 11:23:17
Info AD 9.2.3 dallas Unreachable 11/26/97 10:59:32
Info AD 9.2.3 dallas COM OK (Kickoff) 11/26/97 10:56:54
Info FP fp93 event: 9.3.B grp:0-0 code:12 11/25/97 18:16:45
Info FP fp93 event: 9.3.B grp:0-0 code:1 11/25/97 18:16:45
Last Command: dsplog
Next Command:
The tststats command displays a summary of the test statistics that result from performing a tstcon command on various network connections.
Jobs: No Log: No Lock: No Node Type: IPX, IGX, BPX
tstcon
| [clear] | specifies that the test statistics buffers be cleared. |
Before tststats displays any meaningful statistics, the tstcon command must run on one or more network connections. Refer to the Command Reference for information on the tstcon command. The following are displayed for voice, data, and frame relay connections.
Figure 1-88 illustrates a typical test statistics display.
sw150 TN StrataCom IGX 16 8.4 Feb. 1 1997 21:54 GMT Connection Test results since: Date/Time Not Set Type Total Passed Failed Aborted Voice 0 0 0 0 Data 0 0 0 0 Fr Relay 0 0 0 0 Last Command: tststats Next Command:
|
|