|
|
Diagnostic Commands in the CLI
This chapter describes the following diagnostic and troubleshooting commands:
| connect | Logically attach the console or modem I/O port to a specified card in the node in which the CLI session is running. |
| loadcard | Load the specified file into the specified card, start the card, and establish a console connection between the CLI and the TCS slave on the card. |
| test | Run field diagnostics tests from the CLI. |
| read | Read memory and hardware registers accessible by the TCS. For qualified personnel only. |
| write | Write hex values to memory and hardware registers. For qualified personnel only. |
See also the ping command, described in Chapter 4.
Connect the CLI to a line card as a console.
Description
Use the connect command to connect the CLI to the specified line card so it can act as a terminal for a program, such as diagnostics, running on the line card. Type ~. (tilde-dot) to interrupt the connection.
Syntax
connect card# [force] [diagnostic]
Arguments
| card# | The card number, in the range 3-10. (A connection to either of the NP slots is refused.) |
| force | Optionally force this CLI session to take control of the slot even if it was being used by another CLI in the network. |
| diagnostic | Used only when connecting to a card to run diagnostics. See the LightStream 2020 Hardware Reference Manual. |
Load a file into a card, start it, and establish a console connection with its TCS slave.
Description
The loadcard command loads a line card program, such as the operational software or a diagnostic program, into the specified card. The command resets the card, then loads and starts the line card software.
Syntax
loadcard card# [load-address] [filename]
Arguments
| card# | The card number, in the range 3-10. |
| load-address | The load address (optional). Normally, you omit this argument and use the default load address. |
| filename | The name of the file containing the program you want to load (optional). If no filename is specified, this command loads the operational software for the card. |
Run diagnostics on a specified card.
Description
The test command runs diagnostic tests on a specified card to determine whether it should be replaced. If a card fails, record the displayed error codes and report them when returning the card. The software automatically takes the card out of service (changing its status to
testing
), identifies the type of card, and runs appropriate tests, as specified in files in /usr/diag.
Syntax
test card# [-l][-p][-s][-x][-Ffile] test card# -r test card# -m [-Ffile]
Switches
| -Ffile | Load diagnostics from file rather than from the default file for the card. file can only be a copy of the default file, and you must ensure that file matches the card type. |
| -l | Run tests that require looping plugs or cables. For additional details, see the LightStream 2020 Hardware Reference Manual.. |
| -m | Access the diagnostics interface to run tests interactively. This is equivalent to loading the manufacturing diagnostics with loadcard and connecting to the card (see the Lightstream 2020 Hardware Reference Manual). The following message is the last displayed after the diagnostics have been loaded:
fcload: slot
card#: releasing per-slot synchronization lock.
Press [Return] periodically until the prompt appears. Type ? for a list of tests. Type [^C] to terminate a test in progress. Type ~. to exit. The -r switch cannot be used to retrieve output of test -m. |
| -p | Poll test output approximately every second until completion or timeout. Tests completed between these snapshots are not displayed. If a test runs longer than one polling interval, successive dots indicate the successive polls. A test in progress may be terminated with [^C]. The -r switch may be used after completion. |
| -r | Retrieve results of tests, until the card status changes to
active
or
inactive
or until the card is loaded with some other software, overwriting the memory locations in which test results are stored. If the same test is active over successive polls with test -r, the
heartbeat
value in the display indicates whether the diagnostics are running.
The -r switch does not retrieve results of tests run interactively with the -m switch. |
| -s | Run tests that loop data through the switch fabric for the specified slot.
Do not use the -s switch on an operational system. If the card is defective, spurious data could be communicated over the network. |
-x
|
Run long memory tests. These extended tests may take an hour or more to run. |
The default behavior, with only the card# argument, is to run standard pass/fail tests in the background. The -l, -s, and -x switches add other tests to the default set. Test results can be viewed during the test run if the tests are invoked with the -p switch, or retrieved later with the test -r command.
Read memory and hardware registers accessible by the TCS.
Write memory and hardware registers accessible by the TCS.
Copyright 1988-1996 © Cisco Systems Inc.
![]()
![]()
![]()
![]()
![]()
![]()
![]()