Using the CiscoWorks NetView Interface

Using the CiscoWorks NetView Interface

Using the CiscoWorks NetView Interface

This chapter contains the following topics:


Understanding the PCA

This section describes how the PCA is used to monitor and troubleshoot router activity via NetView. This process is completed by converting network traps and events into SNA Network Management Vector Transport (NMVT) or alerts.

Once you start the PCA using the SNM console Glyph menu command, PCA Start, PCA registers itself with the SNM event dispatcher to receive all the SNMP events and traps. There is no manual intervention required. Once the event or trap is received, it is converted to an NMVT and can be viewed on the NetView NPDA screen. See Figure 6-1.

For more details on the PCA, refer to the 7.0 SunLink SNA Peer-to-Peer Administrator's Guide.

nm020.gif

Figure 6-1 : Events Displayed in IBM NetView's NPDA Screen

PCA runs as a part of SunNet Manager (SNM). The SNM event logger receives events and traps and shares this data with the PCA.


Note: PCA forwards all traps. There is no filtering of traps allowed using the events table. To filter trap data using the machine table, place a filter on a specific machine that you do not want to receive event or trap information on.


RUNCMD Process Overview

The RUNCMD process allows you to perform certain system administration functions from the NetView console. For the RUNCMD process, the CiscoWorks NetView Interface shares the functionality of CiscoWorks with NetView. These RUNCMD commands are issued at the NetView console.

CiscoWorks NetView Interface receives RUNCMD requests from NetView operators and executes the commands on the local UNIX system. To execute the RUNCMD in the IBM NCCF facility, the IBM NetView operator has to edit the scope of command for their operators. Refer to the IBM manual, NetView Installation and Administration SC30-3476.

The following process describes the interaction between the NetView console and the CiscoWorks NetView Interface. The IBM NetView operator issues and displays the RUNCMD requests and receives output on the NetView Command Control Facility (NCCF).

The NetView operator manually requests network information from CiscoWorks using the RUNCMD command. NetView locally defines the NetView operator's access rights for command requests.

The RUNCMD Server receives the request, translates the command to ASCII, and forks, or spawns, a local command processor (UNIX shell) to execute the command.

The RUNCMD Server converts the output from UNIX into extended binary-coded decimal interchange code (EBCDIC, constructs a response to execute a command, and generates an automatic response for transmission to NetView when the command execution has completed.

The following conditions must be satisfied in order for the RUNCMD process to work:

You can invoke the RUNCMD commands from the CiscoWorks workstation. For example, entering netmenu at the UNIX prompt will display the available RUNCMD commands.

The following section describes the general syntax of the RUNCMD and lists the command options.


Specifying RUNCMD Requests

Before a NetView operator can request information via RUNCMD commands, the IBM system administrator must locally define the NetView operator's access rights for command requests. Contact your IBM system administrator and request this type of access. For more information on editing the scope of command, refer to the IBM document, NetView Installation and Administration SC30-3476.


Note: Since this section is used by the IBM NetView operator, you may want to pull this section out and have them use it for a reference.

Use the following syntax to specify RUNCMD requests:

RUNCMD sp=service point name, appl=sh, command_string

The following list describes the command parameters of this syntax:

For example, CISCONV might be the service point (PU name) when using the
CiscoWorks NetView Interface. The PU name must be upper case.

Always use sh (shell) for the application name when using the CiscoWorks NetView Interface.

For example, contacts machine_name would be the command string to enter. The command is contacts and the other command parameters are the machine_name.

Table 6-1 describes the CiscoWorks-supported RUNCMD commands available with the CiscoWorks NetView Interface. These commands and their parameters are described in greater detail later in this chapter. For more information on adding your own commands to the RUNCMD file, refer to the next section, "Writing a Customized RUNCMD."

Time Saver: For help with RUNCMD syntax, type command help at the system prompt.

fig_1.gif

Table 6-1 : RUNCMD Command Descriptions

Command Command Parameters When to Use
cmpconf1 device user password To compare a device's configuration file with the one in the CiscoWorks database.
contacts device To retrieve available contact information on a device from the CiscoWorks database if that device goes down.
getconf1 device community user password To retrieve a Cisco router's configuration file.
ifstatus device.domain interface To query a Cisco device's interface status.
neticmp device.domain community To show a device's ICMP information.
netif device.domain community To access interface activity to assess potential problem areas, such as error rate inconsistencies or threshold, packet volume thresholds, or underutilization of a circuit.
netmenu None To access a list of available RUNCMDs provided by the CiscoWorks NetView Interface.
netroute device.domain community To review the current status of network destination nodes and interface traffic.
netset device.domain interface_name2 up/down To set a devices interface up or down.
netstatus device community To query a remote device's status information including device uptime and software version. Provide this version information when you contact your technical support specialist.
shomibvar device.domain variable_name To show the value of specified Cisco MIB variables from Cisco devices.
showflash device.domain community To retrieve Flash memory data on a Cisco device.
showif device user password To retrieve the interface information of a Cisco device from the CiscoWorks database.
tracepath source destination To display a network path as a series of network hops.

1 cmpconf and getconf use the community string from the Sybase database, which should be RW (ReadWrite) accessible.
2 The domain and interface_name must be spelled out. For example, device_1.cisco.com ethernet0. This device must also have a Write community string defined on the SNM Properties sheet for snm_cmd to work properly.

Time Saver: Community and domain are optional parameters on all but the netset command. If not specified, RUNCMD will use the default community string, public.

fig_2.gif


Sending a RUNCMD Request

From the NetView console at the NCCF facility, the operator types in the RUNCMD string. The RUNCMD requires that you indicate the device, or service point, you are sending the RUNCMD to and a command string to pass to the service point. The RUNCMD commands are not case sensitive.

Figure 6-2 shows an example window of a RUNCMD request and the response from CiscoWorks.

nm019.gif

Figure 6-2 : RUNCMD Request from NCCF Facility

The following sections describe each RUNCMD command in greater detail and provides examples of these commands and resulting system output.


Note: For brevity, ellipses (...) are interspersed throughout the sample output to indicate that output that is displayed on the screen during the RUNCMD process is not included here.


cmpconf

Use the cmpconf command to compare a given device's configuration file stored in Sybase with a current configuration on a Cisco device. This command generates output similar to the CiscoWorks Configuration Management application.

For more information on configuration management, refer to the CiscoWorks User Guide, Chapter 5, "Managing Cisco Device Configurations."

RUNCMD sp=CISCONV,appl=sh,cmpconf device user password

Where:

  • device---Device name to retrieve the configuration file for the comparison

  • user---Database user ID

  • password---Database password

The following is an example cmpconf command:

RUNCMD sp=CISCONV,appl=sh,cmpconf device_1 nms beta

This command sends a response similar to the following to NetView:

Compare Config Host Name: device_1
Thu Mar 11 11:15:44 PST 1993

#Compared Devices Summary
#Started : Thu Dec 10 11:14:44 1992
device_1   //Result: different
******** Compare Config Log File ********
******** Started : Thu Dec 10 11:15:44 1992 
#Compare Result File
#Started : Thu Dec 10 11:15:44 1992
===================================================
*** Database*Tue Nov 17 11:18:49 1992
--- device_1*Thu Dec 10 11:15:54 1992
****************
*** 22,35 ****
  |
  interface TokenRing 0
  no ip address
-  shutdown
...
...
...
  clockrate 4000000
  |
  interface Ethernet 1
***************
*** 64, 69 ****
--- 63, 69 ----
  snmp-server community
  snmp-server community poppaa RW
  snmp-server community public RO
+  snmp-server host 131.108.60.82 public
hostname device_1
  |


contacts

Use the contacts command to retrieve emergency contact information including names, phone numbers, and addresses for an administrator of a Cisco device. This command retrieves this information from the CiscoWorks database (Sybase) and generates output similar to CiscoWorks Contacts application. For more information on the CiscoWorks Contacts application, refer to Chapter 3, in the section "Using Device Contacts" in the CiscoWorks User Guide.

RUNCMD sp=CISCONV,appl=sh,contacts device

Where:

  • device---Device name to retrieve the contact information

The following is an example contacts command:

RUNCMD sp=CISCONV,appl=sh,contacts device_1

This command sends a response similar to the following to NetView:

Host Name: device_1
Thu Mar 11 11:01:55 PST 1993

Joe Newman
123 First Street
Mytown, CA 
USA, 94025
email: jnewman
(415) 455-0000

Scarlet Utara
333 Second Street
Brettown, MI 89999
e-mail: stara

If there are no contacts in the database for this device, you receive the following message:

Host Name: device_1
Thu Dec 10 11:01:55 PST 1992

No contacts found for device_1


getconf

Use the getconf command to retrieve a Cisco router's configuration file.This command generates output similar to the CiscoWorks Configuration Management application.

RUNCMD sp=CISCONV,appl=sh,getconf device community user password

Where:

  • device---Device name to retrieve the configuration file for the comparison

  • community---Community string for device

  • user---Database user ID

  • password---Database password

The following is an example getconf command:

RUNCMD sp=CISCONV,appl=sh,getconf device_1 public nms beta

This command sends a response similar to the following to NetView:

View Config Host Name: device_1
Wed Feb  3 17:00:22 PST 1993

********  Get Config Log File ********
******** Started : Wed Feb  3 17:00:27 1993

version 9.1
!
hostname sloth
!
enable-password xxxx
!
boot network sloth-confg 131.108.1.111
boot network sloth-confg 131.108.13.111
boot system sloth-system 131.108.13.111
boot system sloth-system 131.108.1.111
!
exception dump 131.108.13.111
...
...
interface Ethernet 1
ip address 131.108.42.8 255.255.255.0
delay 100000
appletalk cable-range 4042-4042 4042.8
appletalk zone Engineering
!
interface Serial 1
no ip address
!
...
... 


ifstatus

Use the ifstatus command to retrieve Cisco device's interface status. This command generates output similar to an SNM Quick Dump:cisco:ifstatus function for a requested interface. This command uses the SNM snm_cmd command, which queries on a given interface by name. Refer to the SunNet Manager 2.0 Reference Guide for more information on snm_cmd.

RUNCMD sp=CISCONV,appl=sh,ifstatus device. domain interface

Where:

  • device---Device name to retrieve the interface information

  • domain---Portion of the name in the Internet hierarchy tree

  • interface---Connection between two system devices

The following is an example ifstatus command:

RUNCMD sp=CISCONV,appl=sh,ifstatus device_1.cisco.com ethernet0

This command sends a response similar to the following to NetView:

   Host Name: device_1
   -          Thu Feb  4 11:35:13 PST 1993
    -
     -          Success: timestamp = 728854522.138995
      -          netmgt_schema: cisco
       -          ifIndex: 2
        -          ifDescr: Ethernet0
         -          ifType: 6
          -          ifMtu: 1500
           -          ifSpeed: 10000000
            -          ifPhysAddress: 00000c02084e
             -          ifAdminStatus: 1
              -          ifOperStatus: 1
               -          ifLastChange: 8176413
                -          ifSpecific: 0.0
                 -          (End of row)
                 (End of report)
                  -
                   -          (Last report from agent)
                    -
                     -           Status: Up  = 1
                      -                   Down = 2             


neticmp

Use the neticmp command alone or with other information.This command allows a quick comparison of cumulative ICMP activity and generates output similar to Show IP Traffic from the CiscoWorks Show Commands application.

Refer to the Router Products Configuration and Reference publication for a detailed description of the show ip traffic command.

RUNCMD sp=CISCONV,appl=sh,neticmp device. domain community

Where:

  • device---Device name to retrieve the interface information

  • domain---Portion of the name in the Internet hierarchy tree

  • community---Community string for device

The following is an example neticmp command:

RUNCMD sp=CISCONV,appl=sh,neticmp device_1.cisco.com poppaa

This command sends a response similar to the following to NetView:

Host Name: device_1
Fri Mar 5 8:05:44 PST 1993

IP Statistics:
  Rcvd:*746280 total, 587748 local destination
*0 header errors, 0 address errors
*0 security failures
  Flags: 0 reassembled, 0 reassembly failures
*0 fragmented, 0 couldn't fragment
    Sent:*558947 generated, 158531 forwarded
*0 no route

ICMP Statistics:
    Rcvd:*0errors, 0 redirects, 12 unreachable, 10 echo
*14 echo reply, 0 mask requests, 0 mask replies, 0 quench
*0 parameter problem, 0 timestamps, 0 timestamp replies
*0 time exceeded
    Sent:*0 errors, 0 redirects, 0 unreachable, 25 echo
*10 echo reply, 0 mask requests, 0 mask replies, 0 quench
*0 parameter problem, 0 timestamps, 0 timestamp replies
*0 time exceeded

UDP Statistics:
    Rcvd:*3821 total, 0 errors, 24 no port
    Sent:*529650 total

TCP Statistics:
    Rcvd:*3821 total, 0 errors
    Sent:*2492 total

EGP Statistics:
    Rcvd:*0 total, 0 errors
    Sent:*0 total, 0 errors


netif

Use the netif command to access Cisco device interface information. This information includes the interface name, IP address, IP net mask designation, input packets and errors, and output packets and errors. This command generates output similar to Show Interface from the CiscoWorks Show Commands application.

Refer to the Router Products Configuration and Reference publication for a detailed description of the show interface command.

RUNCMD sp=CISCONV,appl=sh,netif device. domain community

Where:

  • device---Device name to retrieve the interface information

  • domain---Portion of the name in the Internet hierarchy tree

  • community---Community string for device

The following is an example netif command:

RUNCMD sp=CISCONV,appl=sh,netif device_1.cisco.com poppaa

This command sends a response similar to the following to NetView:

Host Name: device_1
Fri Mar 5 10:51:46 PST 1993

TokenRing0 is administratively down, line protocol down
Hardware is 16/4 Token Ring, address is 0000.0000.0000
MTU is 8136 bytes, BW 16000 Kbit, DLY 630 usec, rely 255/255, load 1/255
Encapsulation SNAP, keepalive is set
Last input never, output never, output hang never
Output queue 0, 0 drops, input queue 0 drops
Five minute input rate 0 bits/sec, 0 packets/sec
Five minute output rate 0 bits/sec, 0 packets/sec
   0 packets input, 0 bytes, 0 no buffer
   Received 0 broadcasts, 0 runts, 0 giants
   0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 aborts
   0 packets output, 0 bytes
   0 output errors, 0 collisions, 0 interface resets, 0 restarts

Ethernet0 is up, line protocol down
Hardware is MCI Ethernet, address is 0000.0c02.084e
MTU is 1500 bytes, BW 10000 Kbit, DLY 1000 usec, rely 255/255, load 1/255
Encapsulation ARPA, keepalive is set
Last input never, output 0:00:07, output hang never
Output queue 0, 0 drops, input queue 0 drops
Five minute input rate 0 bits/sec, 0 packets/sec
Five minute output rate 0 bits/sec, 0 packets/sec
   0 packets input, 0 bytes, 0 no buffer
   Received 0 broadcasts, 0 runts, 0 giants
   0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 aborts
   23511 packets output, 2757693 bytes
   0 output errors, 0 collisions, 23104 interface resets, 0 restarts    


netmenu

Use the netmenu command to provide a list of available RUNCMD commands in the CiscoWorks NetView Interface.

RUNCMD sp=CISCONV,appl=sh,netmenu

In the following netmenu command statement, the NetView operator requests the list of RUNCMD commands.

RUNCMD sp=CISCONV,appl=sh,netmenu

The following response is sent to NetView:

The CiscoWorks RUNCMD commands

             ..         ..
             ||         ||
             ||         ||
            ||||       ||||
        ..:||||||:...:||||||:..

 For command syntax type: command help

 COMMAND               USAGE

 cmpconf               Compare configuration on the device with
                       the configuration on database

 contacts              Get the sysadmin contact name for a router

 getconf               Request configuration for a router

 ifstatus              Retrieve a given Interface status

 neticmp               View IP Routing Statistics for a router

 netif                 View Interface Detail Status of a router

 netmenu               View CiscoWorks NetView Interface RUNCMDs

 netroute              View routing table of a router

 netset                Set a router interface up or down

 netstatus             View software version running on a router

 shomibvar             Retrieve MIB variable information

 showflash             Shows Flash memory data on a Cisco device.

 showif                View Interface name and Protocol Address

 tracepath             Request a path from Device A to a Device B   


netroute

Use the netroute command to display Cisco device routing table information. This command generates output similar to Show IP Route in the CiscoWorks Show Commands application.

Refer to the Router Products Configuration and Reference publication for a detailed description of the show ip route command.

RUNCMD sp=CISCONV,appl=sh,netroute device. domain community

Where:

  • device---Device name to retrieve the interface information

  • domain---Portion of the name in the Internet hierarchy tree

  • community---Community string for device

The following is an example netroute command:

RUNCMD sp=CISCONV,appl=sh,netroute device_1.cisco.com poppaa

This command sends a response similar to the following to NetView:

Host Name: device_1.cisco.com
Fri Mar 5 11:01:04 PST 1993

Codes: I - IGRP derived, R - RIP derived, H - HELLO derived
       C - connected, S - static, E - EGP derived, B - BGP derived
       i - IS-IS derived, O - OSPF derived
       * - candidate default route

Gateway of last resort is 150.136.10.162

I Net 0.0.0.0 [8859] via 150.136.10.162, 76 sec, Ethernet1
I Net 11.0.0.0 [1673] via 150.136.10.162, 70 sec, Ethernet1
I Net 100.0.0.0 [1636] via 150.136.10.162, 70 sec, Ethernet1
I Net 128.18.0.0 [9049] via 150.136.10.162, 70 sec, Ethernet1
I Net 130.33.0.0 [10949] via 150.136.10.162, 70 sec, Ethernet1
I Net 130.93.0.0 [183044] via 150.136.10.162, 71 sec, Ethernet1
I Net 130.107.0.0 [10949] via 150.136.10.162, 71 sec, Ethernet1
I Net 131.108.0.0 [1373] via 150.136.10.162, 71 sec, Ethernet1
I Net 131.119.0.0 [8949] via 150.136.10.162, 71 sec, Ethernet1
I Net 132.249.0.0 [11149] via 150.136.10.162, 71 sec, Ethernet1
I Net 134.156.0.0 [8949] via 150.136.10.162, 71 sec, Ethernet1
I Net 134.163.0.0 [8949] via 150.136.10.162, 71 sec, Ethernet1
I Net 138.55.0.0 [8949] via 150.136.10.162, 71 sec, Ethernet1
...
...
C Net 150.136.0.0 is subnetted (mask is 255.255.255.0)
I     150.136.1.0 is possibly down, routing via 150.136.10.162, Ethernet1
C  150.136.10.0 is directly connected, Ethernet1
I  150.136.11.0 [8586] via 150.136.17.164, 17 sec, Fddi0
I  150.136.15.0 [1163] via 150.136.10.162, 72 sec, Ethernet1
C  150.136.17.0 is directly connected, Fddi0
I   150.136.19.0 [180581] via 150.136.17.164, 18 sec, Fddi0            


netset

Use the netset command to change a Cisco device's interface status to up or down. This command uses the SNM snm_cmd.

Refer to the 7.0 SunLink SNA Peer-to-Peer Administrator's Guide for a detailed description of the snm_cmd command.

RUNCMD sp=CISCONV,appl=sh,netset device. domain interface_name {up|down}

Where:

  • device---Device name to retrieve the interface information

  • domain---Portion of the name in the Internet hierarchy tree

  • interface_name---Connection between two system devices

  • up|down---Sets the interface up or down

The following is an example netset command:

RUNCMD sp=CISCONV,appl=sh,netset device_1.cisco.com ethernet0 up

This command sends a response similar to the following to NetView:

Host Name: device_1
Thu Feb  4 11:41:01 PST 1993

Success: timestamp = 728854869.509537
Request succeeded.


netstatus

Use the netstatus command to query Cisco device status information, including device uptime and software version. This command generates output similar to Show Version in the CiscoWorks Show Commands application.

Use this command to provide version information when you contact your technical support specialist. Refer to the Router Products Configuration and Reference publication for a detailed description of how to read the version data.

Refer to the Router Products Configuration and Reference publication for a detailed description of the show version command.

RUNCMD sp=CISCONV,appl=sh,netstatus device community

Where:

  • device---Device name to retrieve the configuration file for the comparison

  • community---Community string for device

The following is an example netstatus command:

RUNCMD sp=CISCONV,appl=sh,netstatus device_1 poppaa

This command sends a response similar to the following to NetView:

Host Name: device_1
Fri Mar 5 16:02:02 PST 1993

GS Software (GS3-BFX), Version 9.0(1), SOFTWARE fc4
Copyright (c) 1986-1992 by cisco Systems, Inc.
Compiled Mon 11-May-92 12:13 by block

System Bootstrap, Version 4.5(1), SOFTWARE
Copyright (c) 1986-1992 by cisco Systems

device_1 uptime is 4 days, 7 hours, 10 minutes, 9 seconds
System restarted by power-on
Running default software

CSC3 (68020) processor with 4096K bytes of memory.
X.25 Software.
Bridging Software.
2 Ethernet/IEEE 802.3 interface.
1 Token Ring/IEEE 802.5 interface.
2 Serial network interface.


shomibvar

Use the shomibvar command to show the value of specified Cisco group MIB variables from Cisco devices. A list of supported Cisco group MIB variables appears in Table 6-2. This table includes group MIBs from Software Release 8.1 through 9.1.

RUNCMD sp=CISCONV,appl=sh,shomibvar device. domain variable_name

Where:

  • device---Device name to retrieve the interface information

  • domain---Portion of the name in the Internet hierarchy tree

  • variable_name---Supported CiscoWorks MIB variable name

Table 6-2 : Supported Cisco Group MIB Variables for Use with shomibvar

Supported Group Variables
appletalk
appletalkProtocols
decnet
egp
fddi-number
icmp
interfaces
ipStatus
ip
lflash
lip
lsystemGeneral
lsystemSecurity
lsystemEnv
lsystemEnvTemp
lsystemEnvVoltage
lsystemMemory
lsystemContacts
lsystemBuffers
lsystemSmbuffers
lsystemMdbuffers
lsystemBgbuffers
lsystemLgbuffers
lsystemHgbuffers
lsystemNetconfig
lsystemCPUload
lts
novell
snmp
snmpStatus
system
tcp
transmission
udp
vines
xns

The following is an example shomibvar command:

RUNCMD sp=CISCONV,appl=sh,shomibvar device_1.cisco.com ipAddrTable

This command sends a response similar to the following to NetView:

Host Name: device_1.cisco.com
Fri Mar 5 16:17:58 PST 1993

Success: timestamp = 723514679.361930
netmgt_schema: snmp-mibII
netmgt_table_key: 1
ifIndex: 1
ifDescr: TokenRing0
...
...
ifSpecific: 0.0
(End of row)
ifType: 6
ifMtu: 1500
ifSpeed: 10000000
ifPhysAddress: 00000c0207f2
ifAdminStatus: 1
ifOperStatus: 1
ifLastChange: 1164
ifSpecific: 0.0
(End of row)

netmgt_table_key: 3
ifIndex: 3
ifDescr: Serial0
ifType: 22
ifMtu: 1500
ifSpeed: 1544000
ifPhysAddress: 00000c0207f2
ifAdminStatus: 1
ifOperStatus: 2
ifLastChange: 20205014
ifSpecific: 0.0
(End of row)
...
...
(End of report)

(Last report from agent) 


showflash

Use the showflash command to show the Flash memory data on a Cisco devices.

Refer to the Router Products Configuration and Reference publication for a detailed description of the show flash command.

RUNCMD sp=CISCONV,appl=sh,showflash device. domain community

Where:

  • device---Device name to retrieve the interface information

  • domain---Portion of the name in the Internet hierarchy tree

  • community---Community string for device

The following is an example showflash command:

RUNCMD sp=CISCONV,appl=sh,showflash polaris.cisco.com poppaa

This command sends a response similar to the following to NetView:

showflash enterprise.cisco.com

Host Name: enterprise
Fri Jan 15 13:53:41 PST 1993

4096K bytes of flash memory.
Flash VPP dip is not installed.

file  length         name
  0   2018552      gs3-k.91-2.2
  [2175624/4194304 bytes free]          


showif

Use the showif command to retrieve device interface information from the CiscoWorks database.

RUNCMD sp=CISCONV,appl=sh,showif device. domain community

Where:

  • device---Device name to retrieve the interface information

  • domain---Portion of the name in the Internet hierarchy tree

  • community---Community string for device

The following is an example showif command:

RUNCMD sp=CISCONV,appl=sh,showif device_1.cisco.com poppaa

This command sends a response similar to the following to NetView:

interface name  protocol addr
Ethernet0  131.108.42.85
Ethernet1  131.108.55.1

The standard output response includes the interfaces that are active and their address.


tracepath

Use the tracepath command to display a network path as a series of network hops. This command uses the CiscoWorks Path Tool application in ASCII output.

RUNCMD sp=CISCONV,appl=sh,tracepath source destination

Where:

  • source---Device name or IP address of device where path begins

  • destination---Device name or IP address of device where path ends

The following is an example tracepath command:

RUNCMD sp=CISCONV,appl=sh,tracepath 192.31.8.239 131.108.2.57

This command sends a response similar to the following to NetView:

Path from rmodule-ss2 to park
Thu Mar 11 14:42:11 PST 1993

Thu Mar 11 14:42:13 1993
Starting path discovery...
Hop #0: rmodule-ss2: out le0
Hop #1: debitt.CISCO.COM: in Ethernet3, out Fddi0
Hop #2: devo.cisco.com: in Fddi0, out Ethernet3
Hop #3: jazzy.CISCO.COM: in Ethernet0, out Ethernet3
Hop #4: Park: in Ethernet0
Path discovery complete.
Thu Mar 11 14:42:21 1993


Creating a Customized RUNCMD

In addition to the standard RUNCMD commands provided by the CiscoWorks NetView Interface, you can add customized commands. These customized commands format CiscoWorks output as UNIX standard output to the NetView console.

The following are examples of why you might write a customized command:

  • To query the network for device data not available through RUNCMDs

  • To create a report from previously gathered polling data

  • To save time

  • To create a customized PCA event table


Note: Your .cshrc file must include the directory path where your customized RUNCMD executable file resides.


Writing a Customized RUNCMD

To write your own customized command statement, perform the following steps:

Step 1: Create an executable shell program containing the command request that generates a response as UNIX standard output.

Step 2: Place the shell program in a directory where your PATH statement can locate it.

Step 3: Create a directory named $NMSROOT/temp/custom_cmds to store any customized RUNCMDs you create.

Step 4: To add this directory to your path, edit your .cshrc file and add the $NMSROOT/temp/custom_cmds directory to the path.


Note: The customized RUNCMD executable file must be located in a directory which is in your path.

Use the RUNCMD statement you have written just as you would any other RUNCMD command at the NetView console. There are no limits to the number of customized RUNCMDs you can create. Just be aware of your system memory limitations.

This document includes a sample of a customized RUNCMD commands. This sample customized RUNCMD collects interface data on a device or devices you specify.

You can edit this sample script and rename it if you want to extend the list of customized commands you have at your disposal.


Sample Customized RUNCMD for Collecting Interface Data

This section contains a sample customized RUNCMD designed to display the ifIndex value for each interface on a device. The RUNCMD name is show_if_ids.

The important part of the show_if_ids script is the Structured Query Language (SQL). SQL is a high-level language for the Sybase relational database. The SQL statement in the script contains the following statements:

select interface_name 'Interface Name', interface_id ifIndex
from interfaces, devices
where interfaces.device_id = devices.device_id
and devices.device_name = '$DEVICE'
order by interface_name

The following list describes what function each line performs in the previous SQL statement:

  • The following line displays the interface name and index. Each column name is followed by a more readable string that will be used to display the output.
select interface_name 'Interface Name', interface_id ifIndex

  • The following lines join the Interfaces table with the Devices table:
from interfaces, devices
where interfaces.device_id = devices.device_id

  • The following line throws away any rows that do not have the device name = $DEVICE:
and devices.device_name = '$DEVICE'

  • The following line sorts the data by interface name:
order by interface_name

For more information on SQL and Sybase, refer to your Sybase documentation set (Transact-SQL User's Guide and System Administration Guide).


Running the show_if_ids command

Use the following syntax to request your customized RUNCMD:

RUNCMD sp=CISCONV, appl=sh, show_if_ids user password device_name

Where:

  • user---Database user ID

  • password---Database password

  • device---Device name to retrieve the interface information

The following is an example show_if_ids command:

RUNCMD sp=CISCONV, appl=sh, show_if_ids nms beta device_1

This command sends a response similar to the following to NetView:

select interface_name 'Interface Name', interface_id ifIndex
List of interfaces and their ids (ifIndex) for gordy

 Interface Name                   ifIndex
 -------------------------------- -------
 Ethernet0                              1
 Ethernet1                              3
 Ethernet10                            16
 Ethernet11                            17
 Ethernet12                            18
 Ethernet13                            19
 Ethernet14                            20
 Ethernet15                            21
 Ethernet2                              5
 Ethernet3                              7
 Ethernet4                              9
 Ethernet5                             10
 Ethernet6                             11
 Ethernet7                             12
 Ethernet8                             13
 Ethernet9                             14
 Fddi0                                 15
 Fddi1                                 22
 Serial0                                2
 Serial1                                4
 Serial2                                6
 Serial3                                8


Sample show-if-ids RUNCMD Script

The following is the customized script for show_if_ids command. You can substitute other MIB variables and parameters to create different customized commands.

#!/bin/sh
#
# show_if_ids: Sample shell script to demonstrate joining two tables
#
# usage: show_if_ids <user_name> <password> <device_name>
#
#~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~~~~~
#
# Function Definitions
#
#~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~~~~~
#
# Function to display usage information
#
usage()
{
  echo "usage: $0 <user_name> <password> <device_name>"
  exit 1
}

#
# Function the check the SYBASE env variable
#
checkenv()
{
  if [ $SYBASE = "" ]; then
    echo "$0: The SYBASE environment variable is not set"
    exit 1
  fi
}
#~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~~~~~
#
# Start of script
#
#~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~~~~~
#
# Check the command line and environment
#
if [ $# != 3 ]; then
  usage
fi
checkenv
#
# Get the command line arguments
#
USER=$1
PASSWORD=$2
DEVICE=$3
#
# Display a title for the output
#
echo
echo "List of interfaces and their ids (ifIndex) for $DEVICE"
echo
#
# Execute the SQL to retrieve the information
#
$SYBASE/bin/isql -U$USER -P$PASSWORD <<EOF

set nocount on
go

/* Get the list of interfaces and ids from the interfaces table.
 * Note that a join is required with the devices table so that the
 * device can be looked up by name
 */
select interface_name 'Interface Name', interface_id ifIndex
from interfaces, devices
where interfaces.device_id = devices.device_id
and devices.device_name = '$DEVICE'
order by interface_name
go

exit
EOF


Note: When a device is down, information is not collected from the device, it is collected through the database.


Running a Customized RUNCMD

To run your own customized command statement, specify your RUNCMD syntax at the NetView console.

RUNCMD sp=CISCONV,appl=unix,custcmd parameters

The following response is sent to NetView:

SAMPLE CUSTOMIZED OUTPUT APPEARS HERE
SAMPLE CUSTOMIZED OUTPUT APPEARS HERE
SAMPLE CUSTOMIZED OUTPUT APPEARS HERE
SAMPLE CUSTOMIZED OUTPUT APPEARS HERE
SAMPLE CUSTOMIZED OUTPUT APPEARS HERE


Creating a Customized Event Table for PCA

This section contains a sample CiscoWorks event table for the SNM Protocol Conversion Application (PCA). Edit the event table to reflect this custom table.

For detailed information on event table format, refer to the 7.0 SunLink SNA Peer-to-Peer Administrator's Guide.

# Event Table Example
###################################
# Using the Default Translation Subvectors
###################################
hostperf data "cpu%" <= 90 ;                    # Specific Event
hostperf data intr ;                            # Any event with intr attribute
-hostperf data intr -< ;                        # Except when relop is -<
hostif if/le0 qlen +> 10 ;                      # "if" table entry = le0
layers udp * +> * ;                             # Any of udp's attributes
layers udp * -> * ;                             # Any of udp's attributes
###################################
# Using User defined subvectors   #
###################################
hostmem mbuf "mbufused" >= 10 : GA = 3320(01) CU = 0700 PC = 2050;
* : GA = 4012(01) PC = 4002 UC = 4002 / 00b2 + E0 "'RUNCMD SP=PUTR0800,AP
PL=SH,F
REECPU <NODE>'";                                # Events not specified will
                                                # translate with these 3 SV.
hostperf data "cpu%" < 99 :
                        GA = 3320(01)
                        CU = 0700
                        PC = 2050;              #
###################
# Entry STARTS here :
###################
hostif if/le0 qlen < 5 :                        # Event Reporting X.25 Alert 6
                        GA = 3320(01)           # Generic Alert SV


                        PC = 2050, 2008, 2006   # Probable Causes SV

                        FC = 20D1,2006 +        # Failure Causes SV with
                                01 "expired",   # 3 qualifiers
                                02 "retry",
                                03 "settings"
                             /3302, 3107, 32d0 +# Recommended Actions that
                                                # Go with the Failure Causes SV
                                01 "called",    # Having
                                02 "calling",   # 3 Qualifiers
                                03 "Local"

                        SV(52) ==               # LCS SV superseding the one
                                                # in Machine table if any
                                "060702010101";
###################
# And ENDS here
###################