cc/td/doc/product/lan/cat3900
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Physical Specifications

Physical Specifications

This appendix provides information about the following:

Physical Dimensions

Table D-1 lists the physical dimensions for a Catalyst 3900.


Table  D-1: Dimensions
Physical Feature Dimension
Rack mounted width 19 in. (482.6 mm)
Standalone width 17.38 in. (441.45 mm)
Depth 15.25 in. (387.35 mm)
Height 3.4 in. (86.36 mm)
Weight 16 lbs (7.26 kg)

Note Rack mount brackets and mounting hardware are included with the unit.

Power Requirements

The Catalyst 3900's auto-ranging power supply operates on line voltage in the range of 90 to 264 VAC (auto-sensing) and 47 to 63 Hz, 150 Watts maximum. An appropriate power cord for the country of installation is shipped with the Catalyst 3900.

Operating Environment

Table D-2 lists the operating environment parameters of a Catalyst 3900.


Table  D-2: Operating Environment
Characteristic Value or Range
Operating temperature 10°C to 40°C (50°F to 104°F)
Operating relative humidity 8% to 80%
Maximum wet-bulb temperature 27°C (81°F)
Thermal dissipation 150 watts (maximum); 512 Btu/hr
Electrical power 1.5 A at 115V; 0.75 A at 230V
Leakage/starting Current less than 3.5 mA/15 amperes/half cycle