This appendix provides system, cabling, and port specifications for the hub.
Table C-1 outlines the system specifications for the hub.
| Description | Specification |
|---|---|
| Environmental Operating Ranges | |
| Nonoperating temperature | -13 to 158°F (-25 to 70°C) |
| Nonoperating humidity | 0 to 90%, noncondensing |
| Nonoperating altitude | up to 30,000 ft (9146 meters) |
| Operating temperature | 32 to 113°F (0 to 40°C) |
| Operating humidity | 0 to 85%, noncondensing |
| Operating altitude | up to 9840 ft (3000 meters) |
| Power Requirements | |
| AC input voltage | 100 to 127 VAC, 200 to 240 VAC |
| Power consumption | 12W |
| Physical Dimensions | |
| Dimensions (H x W x D) | 3.1 x 11.2 x 8.7 in. (7.9 x 28.5 x 22.1 cm)
Height includes the stacking curves on top of the hub. |
| Weight | 2.7 lb (1.2 kg) |
For information on the straight-through Ethernet cables you must supply to connect networking devices to the hub, refer to the "Preinstallation" section in Chapter 2 "Hub Specifications and Cables."
If you are connecting a compatible switch or another Cisco 1528 Micro Hub 10/100, in addition to the straight-through Ethernet cable, you can also use a crossover Ethernet cable. Table C-2 and Table C-3 list the crossover Ethernet cable specifications for connecting a compatible switch and another Cisco 1528 Micro Hub 10/100, respectively.
| Type | Category | Shielding | Maximum Length |
|---|---|---|---|
| 10BaseT | 3 or 5 | Shielded twisted-pair (STP) or unshielded twisted-pair (UTP) | 328 ft (100 meters) |
| 100BaseTX | 5 only | STP or UTP | 328 ft (100 meters) |
| Type | Category | Shielding | Maximum Length |
|---|---|---|---|
| 100BaseTX | 5 only | STP or UTP | 16.4 ft (5 meters) |
For more information on connecting the hub to another Cisco 1528 Micro Hub 10/100, refer to Appendix B, "Cabling Guidelines."
This section contains wiring specifications for the following cables used with the hub:
Table C-4 describes the wiring for the straight-through 10BaseT and 100BaseTX Ethernet cable. Table C-5 describes the wiring for the crossover 10BaseT and 100BaseTX Ethernet cable.
| RJ-45 (from Network Device) Pin | Signal | Direction | RJ-45 (from Hub) Pin |
|---|---|---|---|
| 1 | RX+ | --> | 1 |
| 2 | RX- | --> | 2 |
| 3 | TX+ | <-- | 3 |
| 4 | - | - | 4 |
| 5 | - | - | 5 |
| 6 | TX- | <-- | 6 |
| 7 | - | - | 7 |
| 8 | - | - | 8 |
| RJ-45 (from Network Device) Pin1 | Signal | Direction | RJ-45 (from Hub) Pin |
|---|---|---|---|
| 1 | RX+ | --> | 3 |
| 2 | RX- | --> | 6 |
| 3 | TX+ | <-- | 1 |
| 4 | - | - | |
| 5 | - | - | |
| 6 | TX- | <-- | 2 |
| 7 | - | - | |
| 8 | - | - |
Table C-6 contains wiring specifications for the eight hub ports.
| 8 Pin1 | Description |
|---|---|
| 1 | RX+ |
| 2 | RX- |
| 3 | TX+ |
| 6 | TX- |
|
|